Main -> Local -> Data:

Data Menu

1. Input Mapping

2.Output Mapping

3.Format Select

Data Input and Data Output channel mapping, monitoring, format and tests can be accessed from the sub-menus.

Main -> Local -> Data -> Input Mapping:

Data:

Exit

1010

1

A

1010

1

B

1010

1

This screen allows you to assign a data input channel to a data output channel over a selected fiber port. The number under the middle oscilloscope icon indicates the currently selected input channel. The numbers under the oscilloscope icons to the left and/or right of the middle oscilloscope icon represent the output channel numbers. The arrows to the left and/or right of the middle icon (labeled A and B, respectively indicate over which fibers this mapping is enabled. If the selected input channel is mapped to the output channel then a square-wave is displayed on the oscilloscope icon and the arrow is displayed. If a mapping does not exist for the selected input and output channel pair, then the square-wave and the arrow are not displayed. The status of the input data signal is depicted on the screen of the middle icon:

Z: A high-impedance condition is detected at the data input (i.e. no equipment is driving an active signal).

Data:

Exit

1010

1

A

Z

1010

1

B

1010

1

• H: A high level is detected at the data input (i.e. a logic-1).

Data:

Exit

1010

1

A

H

1010

1

B

1010

1

• L: A low level is detected at the data input (i.e. a logic-0).

Data:

Exit

1010

1

A

L

1010

1

B

1010

1

34

Image 36
Contents Installation instructions Installation Instructions Before You Begin Intended UseCustomer Support Conventions Used in this ManualInstalling Power Supplies Module InstallationGetting Started OverviewInstalling the Optical Transceiver Module Installation instructionsTools and materials required Connect fiberPoint-to-Point Connect Repeater ConnectSelf-Healing Connect LED operating status Optic LEDInstalling the Data Module Configure data moduleSetting Mode Install data module ConnectUsing the breakout box Fiber Link Data ConnectionsPin Signal RS-485 4-WIRE Interface Data module channel sequenceInstalling the Ethernet Module Install the Ethernet moduleConfigure Installing the Video Module Install video input moduleInstall video output module Connection instructions Video InputsVideo Outputs Video Input module channel sequence Video Output module channel sequenceInstalling the Audio Module Configure audio moduleInstalling audio modules Channel sequence is as followsConnecting to audio modules Audio module channel sequence Terminal Block Pin AssignmentsInstalling the Contact Closure Module Install contact closure moduleConnect to the module RJ45 Socket Viewed from the rear of the unitContact Input module channel sequence Configuring the Phoenix Fiber Optic Communications System Turn on power and check status Select the system topologyGE Security Set the Node ID Front Panel Menu Tree and Descriptions Main Menu Main LocalMain Local Node Main Local Node ID Main Local Node TopologyMain Local Node Load Defaults Main Local OpticsMain Local Optics Transmit Main Local Optics ReceiveMain Local Optics Info Main Local VideoMain Local Video Input Mapping Main Local Video Output Mapping Video Test Channel Test Off Format Ntsc Main Local Data Main Local Data Input MappingMain Local Data Output Mapping Main Local Data Format Select Main Local Ethernet Main Local Ethernet Port StatusMain Local -Ethernet Port Control Main Local -Ethernet Port TrafficMain Local Audio Main Local Audio Input MappingMain Local Audio Output Mapping Main Local Audio Test Main Local ContactsMain Local Contacts Input Mapping Main Local Contacts Configure Main Local Contacts Output MappingMain Local Power Main Local TestMain Local Test LED/LCD/Alarm Main Local Test TempMain Local Test Video Main Local Test DataMain Remote Main AboutBlank Panel Installation and Specifications Overview Limited warrantyOptical Transceiver Module Specifications Product orderingData Module Specifications DataEthernet Module Specifications EthernetVideo Module Specifications VideoAudio Module Specifications Product 0rderingContact Closure Module Specifications Contacts / Relays