GE A8950CC installation instructions Main Local Data Format Select, Setting Mode

Page 38

• Square Wave: Active data is detected at the data input.

Data:

1010

Exit 1

A

1010

1

B

1010

1

Please refer to the Video Output Mapping Menu described earlier for important notes regarding channel mapping and instructions on how to enable mappings.

Main -> Local -> Data -> Format Select:

Data:

1. Channel: 1

2.Format: 232 - 3

3.Test: Off

This menu allows the user to view and change the format for a specified data channel. The first line of this menu shows the currently selected channel. The second line shows the current data format. If the switch on the Data Module for the corresponding data channel is set to position 0, then the data format can be modified. If the switch is set to any other position then the format cannot be changed. The third line indicates the status of a test pattern ("OFF" or "ON 1-0-Z"). The test pattern is generated at the specified output channel, so an Input Data Module is not required and channel mappings will have no affect on the test pattern.

Setting

Mode

Setting

Mode

0

Software-selectable (factory preset)

8

RS-485 2-wire 2 V

1

RS-232 (3-wire)

9

RS-485 4-wire standard

2

RS-232 + handshake

A

RS-485 4-wire 1 V

3

TTL

B

RS-485 4-wire 2 V

4

RS-422 2-wire

C

Reserved

5

Manchester/biphase

D

Reserved

6

RS-485 2-wire standard/Sensornet

E

Reserved

7

RS-485 2-wire 1V

F

Test Mode

NOTE: The DATA SELECT switches are shipped in the Software-Selectable setting.

Use "+" and "-" to change selections at each line in the menu. Press "left" to exit this screen. When leaving this menu with test patterns enabled, a warning message comes up alerting that test patterns have been disabled to allow real data to pass.

36

Image 38
Contents Installation instructions Installation Instructions Customer Support Before You BeginIntended Use Conventions Used in this ManualGetting Started Installing Power SuppliesModule Installation OverviewTools and materials required Installing the Optical Transceiver ModuleInstallation instructions Connect fiberSelf-Healing Connect Point-to-Point ConnectRepeater Connect LED operating status Optic LEDSetting Mode Installing the Data ModuleConfigure data module Install data module ConnectUsing the breakout box Fiber Link Data ConnectionsPin Signal RS-485 4-WIRE Interface Data module channel sequenceInstalling the Ethernet Module Install the Ethernet moduleConfigure Install video output module Installing the Video ModuleInstall video input module Video Outputs Connection instructionsVideo Inputs Video Input module channel sequence Video Output module channel sequenceInstalling the Audio Module Configure audio moduleInstalling audio modules Channel sequence is as followsConnecting to audio modules Audio module channel sequence Terminal Block Pin AssignmentsInstalling the Contact Closure Module Install contact closure moduleConnect to the module RJ45 Socket Viewed from the rear of the unitContact Input module channel sequence Configuring the Phoenix Fiber Optic Communications System Turn on power and check status Select the system topologyGE Security Set the Node ID Front Panel Menu Tree and Descriptions Main Local Node Main MenuMain Local Main Local Node ID Main Local Node TopologyMain Local Optics Transmit Main Local Node Load DefaultsMain Local Optics Main Local Optics ReceiveMain Local Video Input Mapping Main Local Optics InfoMain Local Video Main Local Video Output Mapping Video Test Channel Test Off Format Ntsc Main Local Data Main Local Data Input MappingMain Local Data Output Mapping Main Local Data Format Select Main Local -Ethernet Port Control Main Local EthernetMain Local Ethernet Port Status Main Local -Ethernet Port TrafficMain Local Audio Output Mapping Main Local AudioMain Local Audio Input Mapping Main Local Contacts Input Mapping Main Local Audio TestMain Local Contacts Main Local Contacts Configure Main Local Contacts Output MappingMain Local Power Main Local TestMain Local Test Video Main Local Test LED/LCD/AlarmMain Local Test Temp Main Local Test DataMain Remote Main AboutBlank Panel Installation and Specifications Overview Limited warrantyOptical Transceiver Module Specifications Product orderingData Module Specifications DataEthernet Module Specifications EthernetVideo Module Specifications VideoAudio Module Specifications Product 0rderingContact Closure Module Specifications Contacts / Relays