GE A8950CC Connect to the module, RJ45 Socket Viewed from the rear of the unit

Page 23

2. Connect to the module:

Each contact closure module is shipped with (four) RJ45 cables and (four) breakout boxes to aid in connecting to the Phoenix. Use the tables below to determine pin out information for your application. GE Security recommends using shielded cable for all single ended applications and shielded twisted-pair for all differential formats.

Wire gauge is dependent on copper run length. Refer to manufacturer of data equipment for specific recommendations.

Figure 1. Terminal Block Pin Assignments

54

6

 

 

 

 

 

3

 

 

 

 

7

 

 

 

 

2

 

 

8

 

 

 

 

1

 

 

Using the breakout box

A breakout box with a 3’ CAT 5 patch cord (supplied) can be used to interface to the Phoenix system. Pinouts are shown in the tables and figures below.

Figure 2. RJ45 Socket

(Viewed from the rear of the unit)

Pin

1 8

RJ45-A

RJ45-B

RJ45-C

RJ45-D

21

Image 23
Contents Installation instructions Installation Instructions Conventions Used in this Manual Before You BeginIntended Use Customer SupportOverview Installing Power SuppliesModule Installation Getting StartedConnect fiber Installing the Optical Transceiver ModuleInstallation instructions Tools and materials requiredSelf-Healing Connect Point-to-Point ConnectRepeater Connect Optic LED LED operating statusSetting Mode Installing the Data ModuleConfigure data module Connect Install data moduleFiber Link Data Connections Using the breakout boxPin Signal Data module channel sequence RS-485 4-WIRE InterfaceInstall the Ethernet module Installing the Ethernet ModuleConfigure Install video output module Installing the Video ModuleInstall video input module Video Outputs Connection instructionsVideo Inputs Video Output module channel sequence Video Input module channel sequenceConfigure audio module Installing the Audio ModuleChannel sequence is as follows Installing audio modulesConnecting to audio modules Terminal Block Pin Assignments Audio module channel sequenceInstall contact closure module Installing the Contact Closure ModuleRJ45 Socket Viewed from the rear of the unit Connect to the moduleContact Input module channel sequence Configuring the Phoenix Fiber Optic Communications System Select the system topology Turn on power and check statusGE Security Set the Node ID Front Panel Menu Tree and Descriptions Main Local Node Main MenuMain Local Main Local Node Topology Main Local Node IDMain Local Optics Receive Main Local Node Load DefaultsMain Local Optics Main Local Optics TransmitMain Local Video Input Mapping Main Local Optics InfoMain Local Video Main Local Video Output Mapping Video Test Channel Test Off Format Ntsc Main Local Data Input Mapping Main Local DataMain Local Data Output Mapping Main Local Data Format Select Main Local -Ethernet Port Traffic Main Local EthernetMain Local Ethernet Port Status Main Local -Ethernet Port ControlMain Local Audio Output Mapping Main Local AudioMain Local Audio Input Mapping Main Local Contacts Input Mapping Main Local Audio TestMain Local Contacts Main Local Contacts Output Mapping Main Local Contacts ConfigureMain Local Test Main Local PowerMain Local Test Data Main Local Test LED/LCD/AlarmMain Local Test Temp Main Local Test VideoMain About Main RemoteOverview Limited warranty Blank Panel Installation and SpecificationsProduct ordering Optical Transceiver Module SpecificationsData Data Module SpecificationsEthernet Ethernet Module SpecificationsVideo Video Module SpecificationsProduct 0rdering Audio Module SpecificationsContacts / Relays Contact Closure Module Specifications