GE A8950CC installation instructions Configuring the Phoenix Fiber Optic Communications System

Page 25

Configuring the Phoenix Fiber Optic Communications System

This section explains how to configure a Phoenix chassis using the front panel. The front panel has seven status LEDs, an LCD display, seven push buttons and two RJ-45 ports. These RJ-45 ports (labeled LAN and DATA) are currently unused. Do NOT connect any cables or equipment to these ports; it may damage the Phoenix chassis.

Basic configuration of a Phoenix chassis is a three-step process:

1.Turn on power and check status.

2.Select the system topology.

3.Set the node ID.

If your system requires non-default settings (e.g. channel mapping, PAL video, etc.), please refer to the section titled FRONT PANEL MENU TREE AND DESCRIPTIONS after you have completed the basic configuration.

If you have not already done so, install the Power Supply Module(s), Optic Module, and any other plug-in modules (i.e. Data, Video Input, Video Output, etc.) and connect cabling as instructed in the previous sections of this manual

23

Image 25
Contents Installation instructions Installation Instructions Intended Use Before You BeginCustomer Support Conventions Used in this ManualModule Installation Installing Power SuppliesGetting Started OverviewInstallation instructions Installing the Optical Transceiver ModuleTools and materials required Connect fiberRepeater Connect Point-to-Point ConnectSelf-Healing Connect Optic LED LED operating statusConfigure data module Installing the Data ModuleSetting Mode Connect Install data moduleFiber Link Data Connections Using the breakout boxPin Signal Data module channel sequence RS-485 4-WIRE InterfaceInstall the Ethernet module Installing the Ethernet ModuleConfigure Install video input module Installing the Video ModuleInstall video output module Video Inputs Connection instructionsVideo Outputs Video Output module channel sequence Video Input module channel sequenceConfigure audio module Installing the Audio ModuleChannel sequence is as follows Installing audio modulesConnecting to audio modules Terminal Block Pin Assignments Audio module channel sequenceInstall contact closure module Installing the Contact Closure ModuleRJ45 Socket Viewed from the rear of the unit Connect to the moduleContact Input module channel sequence Configuring the Phoenix Fiber Optic Communications System Select the system topology Turn on power and check statusGE Security Set the Node ID Front Panel Menu Tree and Descriptions Main Local Main MenuMain Local Node Main Local Node Topology Main Local Node IDMain Local Optics Main Local Node Load DefaultsMain Local Optics Transmit Main Local Optics ReceiveMain Local Video Main Local Optics InfoMain Local Video Input Mapping Main Local Video Output Mapping Video Test Channel Test Off Format Ntsc Main Local Data Input Mapping Main Local DataMain Local Data Output Mapping Main Local Data Format Select Main Local Ethernet Port Status Main Local EthernetMain Local -Ethernet Port Control Main Local -Ethernet Port TrafficMain Local Audio Input Mapping Main Local AudioMain Local Audio Output Mapping Main Local Contacts Main Local Audio TestMain Local Contacts Input Mapping Main Local Contacts Output Mapping Main Local Contacts ConfigureMain Local Test Main Local PowerMain Local Test Temp Main Local Test LED/LCD/AlarmMain Local Test Video Main Local Test DataMain About Main RemoteOverview Limited warranty Blank Panel Installation and SpecificationsProduct ordering Optical Transceiver Module SpecificationsData Data Module SpecificationsEthernet Ethernet Module SpecificationsVideo Video Module SpecificationsProduct 0rdering Audio Module SpecificationsContacts / Relays Contact Closure Module Specifications