Falcon XG1.5K-1T, XG2.2K-1T, XG3K-1T manual Storage and Transportation, Installation, Battery

Page 3

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

RETAIN THIS USER MANUAL

This manual contains important instructions which must be followed during the installation, operation and maintenance of this UPS and its batteries. Please read all instructions before operating this equipment and save this manual for future reference.

All of the models presented herein are designed for installation and use in a temperature controlled environment, free of contamination.

This UPS operates from utility power and contains a number of high current back-up batteries, this information is important to all personnel involved. Please read this manual first before continuing to unpack, installation and operation of this UPS.

STORAGE AND TRANSPORTATION

This UPS must be handled with care and given special attention due to the high energy stored within its internal sealed lead acid batteries. The shipping container should be retained in the event the UPS needs to be returned for service.

INSTALLATION

Install this UPS in a clean environment, free from moisture, flammable gases or fumes and corrective substances. Operate the UPS in an indoor environment with an ambient temperature range of 32oF to +104oF (0oC to +40oC).

This UPS is designed for scientific and data processing equipment. It is not intended for use with life support and other designated “life-critical” applications.

The maximum UPS output load must not exceed that shown on the UPS rating label. DO NOT CONNECT equipment that could overload the UPS or demand half-wave rectification from the UPS, for example: electric drills, vacuum cleaners or hairdryers.

Storing magnetic media on top of the UPS may result in data loss or corruption.

Warning

This UPS should be installed according to the instructions in this manual. Failure to do so could result in unsafe operation and could invalidate your warranty.

BATTERY

Once batteries have reached the end of their life, ensure they are disposed properly. REFER TO YOUR LOCAL LAWS AND REGULATIONS FOR BATTERY RECYCLING REQUIREMENTS.

3

Image 3
Contents Owners Operating Manual Table of Contents Installation BatteryStorage and Transportation Introduction Circuit Descriptions Block DiagramInstallation RACK-MOUNT UPS Setup FREE-STANDING UPS InstallationInspecting the Equipment Page FREE-STANDING UPS Installation Mounting feet Mounting feet for additional Battery Modules Battery Module Installation SET/ALARM Silence Bypass Display & ControlsFUNCTION/TEST Indicators and Icons Located on the LCD Display FUNCTION/TEST Button ControlsOperating Modes Normal ON-LINE ModeBattery Mode OperationBypass Mode Green ModeTurning the UPS on Turning the UPS OFF UPS Setup ConfigurationHow To Place The UPS Into Setup/CONFIGURATION Mode Green Mode Function BITHow to Enable or Disable Green Mode How to Set the UPS Output VoltageConfiguration Mode Communications An Example of How to Set the UPS Output Voltage to 115VacPIN # RS-232 PortUA88374 Relay Option Board Standard Dry Contact Interface Card Novell styleBattery Pack Replacement MaintenanceUPS and Battery Care When to Replace BatteriesInternal Battery Pack Replacement Recycling the Used Battery Testing NEW BatteriesFuse Replacement Troubleshooting Guide TroubleshootingUPS Troubleshooting GuideInput DimensionsWeight Internal Battery PackModel Number XG2.2K-1T Battery RUN Times General Provisions Warranty