Freescale Semiconductor MMDS0508 manual Disables triggers a and B

Page 65

Freescale Semiconductor, Inc.

Appendix

MMDS Commands

list: A list of trigger identifiers (A, B, C, or D), separated by comma or space characters.

*: All triggers.

A.1.2.9 Description

The TD command disables specified triggers. Use the Set Trigger (ST) command to set triggers; use the Trigger Enable (TE) command to enable triggers. Use the Clear Triggers (CT) command to clear triggers.

Example:

TD A B

Disables triggers A and B.

Example:

TD *

Disables all triggers.

TE

A.1.2.10 Short Description

trigger enable.

A.1.2.11 Syntax

TE list *

list: A list of trigger identifiers (A, B, C, or D), separated by comma or space characters.

*: All triggers.

A.1.2.12 Description

The TE command enables specified triggers. Use the Set Trigger (ST) command to set triggers; use the Trigger Disable (TD) command to disable triggers. Use the Clear Triggers (CT) command to clear triggers.

Example:

MMDS0508 Target Interface

A–65

For More Information: www.freescale.com

Image 65
Contents Freescale Semiconductor, Inc MMDS0508 Target InterfaceHow to Contact Metrowerks Table of Contents Appendix Introduction Mmds FeaturesSystem Components Freescale Semiconductor, Inc System Components MMDS0508 Target Interface Installation M68MMDS0508 Station Module Right Side Factory Test Header J1 Configuring the Platform BoardFactory Test Header J1 Port Voltage Control Headers J2-J4Removing the EM Installing the EMBus State Analyzer Connection Making Cable ConnectionsHost Computer Connection Target Cable Connection Power ConnectionMaking Cable Connections MMDS0508 Target Interface RS232 Serial Connector Reset SwitchSerial Connector and Cable Pin Assignments Logic Cables and ConnectorsPod and Logic Cable Pin Assignments Power Switch/Connector Assembly Power Supply Fuse ReplacementFreescale Semiconductor, Inc Power Supply Fuse Replacement MMDS0508 Target Interface Mmds Target Component MMDS0508 ConfigurationGeneral Interfacing Your System and the Target Definitions, Acronyms and AbbreviationsHardware connection Loading the MMDS0508 TargetLoading MotoSIL Target Communication ConfigurationMotoSIL Communication Configuration Communication Device SpecificationData Format Debugger Status Bar forMMDS0508 Menu Entries Communication Communication Baud RateShow Protocol Memory ConfigurationMaximum Baud Rate 0nnnnVxx.MEM Personality .MEM Files12 Error Message Memory Signals EmulationDual-Port RAM MCU Clock ResetBus Tracing Comdev Default Target SetupMotorola ESL Parameters Introduction to the Bus Analyzer Bus AnalyzerBaudrate ShowprotWatchpoints Using the Bus AnalyzerTrace Modes Trace Buffer15 Bus Analyzer Trace window popup menu17 Bus Analyzer Trigger Setup Trigger SetupSequencer Setup Continuous All Cycles Non-Triggered ModesCounted Modes Triggered Modes/Sequential Event ModeCounted/Sequential Recording Mode Clock Frequency Time Tag Clock SetupCollecting Data Recording Bus Data Viewing Collected DataTrigger Event View CyclesEvents Textual DisplayInstructions Only Display Control SignalsTime Tag Time MeasuringZoom In or Out Graphical Display22 Trace Zoom Display Add / Remove Items in the Trace Window ShowLocationSearch for a Frame Scrolling the DisplayOK Button Search for EventsForward BackwardPrevious Event Search for a PatternPrevious Pattern Cancel ButtonNext Pattern Dump File Dumping the Bus analyzer data to a file31 Analyzer Dump Only Frame Baud Rate Command Mmds CommandsShort Description SyntaxTrigger Commands Set trigger Data RED ORG YEL GRN Examples Disables triggers a and B Bus Analyzer Commands Darm GP B Log trace Open the logging file Sets the 8 Mhz oscillator as the time tag clock source Address SP 8 Set sequencer Display time tag difference VA MODE=MIX INS Graph Reset Commands Target Signal Emulation CommandsOther Commands MEM OSC Protocol Disables the real time memory block Index IDX-84 MMDS0508 Target Interface IDX-85 IDX-86