Freescale Semiconductor, Inc.
Appendix
MMDS Commands
500,000 Hz divided by an integer. Thus, 50000 is valid, but 49000 is not. (If you specify 49000, the system rounds the value up the the next higher valid frequency: 50000.)
A.1.3.21 Description
The SC command sets the source for the time tag clock, which increments the trace buffer time tag. If this command includes no parameter values, the command interpreter opens the Bus Analyzer Configuration dialog box. You can use the Time Tag Clock page to reach the Clock Specification dialog box, then set the clock sources interactively.
Example:
SC PROGRAM 100
Sets the programmable clock, running at 100Hz, as the time clock source.
Example:
SC OSC8MHZ
Sets the 8 Mhz oscillator as the time tag clock source.
SP
A.1.3.22 Short Description
set analyzer search pattern.
A.1.3.23 Description
The SP command defines a search pattern for the bus analyzer trace buffer. The go to pattern (GP) command starts the search for the pattern defined by the most recent SP command. If the SP command includes no parameter values, the command interpreter opens the Bus Analyzer Configuration dialog box. You can use the Pattern page to define the pattern interactively.
A.1.3.24 Syntax
SP [!] [(<address> ,) [(<data> ,) [(<clips> ,)[LIR = (X L H)]]]][;R ;W ;RW]
MMDS0508 Target Interface |
For More Information: www.freescale.com