Briggs & Stratton Power Products Automatic Transfer Switch

Installation and Operator’s Manual

Owner Orientation

The illustrations are for typical circumstances and are meant to familiarize you with the installation options available with your transfer switch.

Local codes, appearance, and distances are the factors that must be considered when negotiating with an installation professional. As the distance from the existing electrical service increases, compensation in wiring materials must be allowed for.This is necessary to comply with local codes and overcome electrical voltage drops.

The factors mentioned above will have a direct effect on the overall price of your transfer switch installation.

NOTE: Your installer must check local codes AND obtain permits before installing the system.

Read and follow the instructions given in this manual.

Follow a regular schedule in caring for and using your transfer switch, as specified in the manual.

Equipment Description

The transfer switches are intended to transfer the entire load of normal residential installations when used with the supervisory contacts provided.The load is connected either to utility power (normal) or home standby power (generator).The transfer switch monitors utility and generator voltages and will automatically connect to the appropriate source of power.

Major components of the transfer switch are a 2 pole disconnect circuit breaker (models 01928-1 & 01929-1 only), a 2 pole double throw transfer switch, control circuit board, fused utility terminals and interconnecting wiring.

The transfer switch is solenoid-operated from utility or generator inputs and contain suitable mechanical and electrical interlock switches to eliminate the possibility of connecting the utility service to the generator output. It has ratings capable of switching full utility power into the residence. In addition, a manual override lever is provided for the transfer function.

Installer Responsibilities

Read and observe the safety rules.

Read and follow the instructions given in this manual.

Check federal, state and local codes.

Ensure generator is not overloaded with selected loads.

The control circuit board has active circuits sensing utility and generator voltages. It creates a signal for the generator start-up, switch transfer, retransfer when utility is restored and generator cool down periods.The control board also contains red and green LED’s indicating the power sources available and two relay operated contacts that provide supervisory control of external loads.

5

Image 5
Contents Amp / 200 Amp Table of Contents Use transfer switch only for intended uses Important Safety InstructionsOnly qualified electricians should attempt installation For the Home Owner IntroductionOwner Orientation Delivery Inspection InstallationShipment Contents Typical Transfer Switch Mounting for Models 01928-1 Power Wiring Interconnections Typical Installation Diagram for Transfer Switch System Operation Testing the Automatic Transfer SwitchFault Current Rating ,000 RMS Symmetrical Amperes SpecificationsUL 1008 Listed Transfer Switch Model Problem Cause Correction TroubleshootingInstallation and Operator’s Manual Models 01813-1 Transfer Switch SchematicModels 01928-1 Transfer Switch Wiring DiagramItems without part numbers are common fasteners Transfer Switch Exploded View & Parts ListDescription DECAL, 200A,ATS LOCKWASHER, #10 BUS BAR Installation and Operator’s Manual Limited Warranty Table DES Matières Guide dinstallation et dutilisationAvertissement Au Propriétaire Résidentiel Au Détaillant ou à lEntrepreneur Procédant à lInstallationIntroduction Description de lÉquipement Responsabilités de lInstallateurConseils au Propriétaire Consignes dinstallation InstallationDéballage Vérification de la LivraisonUne installation alternative du commutateur de transfert Câblage de contrôle Interconnexions du Câblage dAlimentationSchéma dInstallation Typique du Commutateur de Transfert Mise À Lessai DU Commutateur DE Transfert Automatique FonctionnementSéquence Automatique Si vous Devez Communiquer avec lUsineUL 1008 Enuméré Commutateur de Transfert Modéle CaractéristiquesCharge maximum/circuit Valeur nominale desDépannage Garantie Limitée Manual de Instalación y del Operario Tabla DE ContenidoPrecaución AdvertenciaPara el Propietario Doméstico IntroducciónResponsabilidades del Instalador Orientación para el PropietarioDescripción del Equipo Lea y cumpla las instrucciones incluidas en el manualDesempaque InstalaciónPautas de Montaje Inspección al Momento de la EntregaFigura 13 Montaje de un Conectador Alternativo Contactor del Acondicionador de aire Alimentación Neutro Interconexiones de Cableado de EnergíaCableado de Control de Supervisión Figura 11 Un Esquema Típico de Instalación para Conectador Prueba DEL Conectador Automático Sistema FuncionamientoSecuencia Automática Si Necesita Llamar a FábricaReparacion DE Averias Problemo Causa AccionEspecificaciones Garantía Limitada