Table 5. Remote Programming Mode Commands
OP CODE | MNEMONIC/DESCRIPTION |
| COMMAND/ACKNOWLEDGEMENT | |
(HEX) |
|
|
|
|
|
|
|
| |
A7 | NVBDRD | COMMAND: | A7hhhm<CR> | |
| Read a database register. | A7 | = Op Code | |
|
| hhh | = 3 character address representing | |
|
|
| the register to read range "000" to "7FF" | |
|
|
| in ASCII | |
|
| m | = mode to read in | |
|
|
| 0 = string mode up to null | |
|
|
| 1 = raw mode | |
|
|
| read as CxDx (16 bytes) | |
|
| <CR> | = terminate command (0D hex) | |
|
| ACKNOWLEDGEMENT: NONE | ||
|
|
|
| |
A8 | NVBDWR | COMMAND: | A8hhhxx..x<CR> | |
| Write a database register. | A8 | = Op Code | |
|
| hhh | = 3 character address representing | |
|
|
| the register to write | |
|
| xx | = data to write in ASCII or CxDx | |
|
|
| pairs (16 bytes max.) | |
|
| <CR> | = terminate command (0D hex) | |
|
| ACKNOWLEDGEMENT: NONE | ||
|
|
|
| |
A9 | NVBDCLR | COMMAND: | A9CLR<CR> | |
| Clear all database registers. | A9 | = Op code | |
|
| CLR | = required for failsafe operation | |
|
| <CR> | = terminate command (0D hex) | |
|
| ACKNOWLEDGEMENT: NONE | ||
|
|
| ||
AA | CDSECOPN | COMMAND: AAx<CR> | ||
| Used to disable keyboard output if cash | AA | = Op code | |
| x | A = normal | ||
| drawer(s) are open. | |||
|
| B = cash drawer 1 | ||
|
|
| ||
|
|
| C = cash drawer 2 | |
|
|
| D = both drawers | |
|
| ACKNOWLEDGEMENT: NONE |
Series 600 POS Keyboard | 45 |