Table 5. Remote Programming Mode Commands
OP CODE | MNEMONIC/DESCRIPTION |
| COMMAND/ACKNOWLEDGEMENT |
(HEX) |
|
|
|
|
|
| |
B0 | LIGHT | COMMAND: B0Lx<CR> | |
| Provides on/off control for keyboard light | B0 | = Op Code |
| emitting diode (LED) indicators. PC mode | L | = lamp |
| for NUM and CAP Lock lights is default. | x | = on/off |
|
| <CR> | = terminate command (0D hex) |
|
| L: | 0, 1, 2, 3, P in ASCII, where 0 = all. P is |
|
|
| used for PC emulation of NUM and CAPS |
|
|
| Lock |
|
| x: | PC mode |
|
|
| 1 = on; 0 = off |
|
| ACKNOWLEDGEMENT: NONE | |
|
|
|
|
Series 600 POS Keyboard | 47 |