Tannoy ACTIVE STUDIO MONITORS Slave Monitor & Subwoofer, Initializing the Network, Remote Control

Page 12

A C T I V E S T U D I O M O N I T O R S

Slave Monitor & Subwoofer

The slave unit is able to receive and distribute audio and control data via the proprietary TC LINK connection

The TS112 iDP™or TS212 iDP™subwoofer can be used in any iDP system.

Slave Monitor Network Connections

The Slave and Sub units contain one RJ45 Input connector and one Link connector. Via the RJ45 input connector the Slave unit is supplied with audio and control data from the Master unit. Audio signal from the source is fed to the master monitor only and the signal is distributed to the connected slave units through a proprietary networking protocol. A master monitor acts exactly the same as a Slave monitor when its TC Link button is set to the “IN” position, hence it is used for audio inputs only. The network system enables all connected monitors in a setup, whether in a stereo or surround format always to be corresponding. Control of the entire system is possible from one point on the network (Master or Slave), providing great flexibility in terms of control.

Initializing the Network

After connecting the units and powering up for the first time, the Master unit scans the setup in order to determine the number of monitors connected. Each monitor is recognized via a unique serial number but can be renamed according to task. After the initial scanning of the set-up, the Master unit will be re-scanning the setup every 5 seconds in order to determine any change.

Remote Control

Precision iDPmonitor systems can be set up and controlled locally via the Master monitor’s user-interface with the optional remote control or from a PC/Mac. This is achieved by connecting the PC or remote to any free Link connector in the network. Control data is transmitted via the System Controller, and distributed to the other monitors in the network.

iDP SOFT- Software Remote

Parameters in the network including setup parameters can be controlled via iDP SOFTAdditionally, any software upgrades which become available can be installed with this package.

Hardware Remote

This remote control allows access to three user defined Reference level settings, recall of up to four presets, mute/un- mute and solo function for each monitor, and Master level adjustment.

Precision iDP PC-iP

Optional software dedicated for the Advanced Installer. In addition to the common parameters the PC-iPsoftware offers Parametric EQ and various Parameter Lock functions.

12

Image 12
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Concept & Design Philosophy Tannoy Dual ConcentricHigh efficiency compact Switched Mode Power Supply Smps Unpacking & Visual ChecksTannoy WideBand SuperTweeter Speaker Placement Preliminary RecommendationOrientation Master & Slave Concept Remote Control Slave Monitor & SubwooferInitializing the Network IDP Soft Software RemoteMaster Unit Slave/SubwooferSUB General Setup Procedure IDP Display MasterSetups General Setup ProcedureAnalog Stereo Set-up With Mono Subs Analog Stereo Set-up With Stereo Subs Stereo Digital Set-up With Mono SubsAnalog Set-up Digital Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Alternative 7.1 Set-up Analog, Digital& 192kHzConnecting Two Subs Connecting Three SubsDig/6 Master Stereo Set-up With Chains on L&R. Analog or DigitalSetup when the monitors are connected Reset Procedure Reset All SettingsSelect Setup Select Monitor TasksPress Enter to access the Select Mode Parameter DescriptionMain Display † PC-iPPhase Bass ManagementLFE Low Pass Filter LFE GainSetup Menu SetupSet Monitor Task External ClockParameters available for the subwoofer LFE channel importantParameter Categories IDP Remote Preset 1/3 and 2/4 keys Volume potentiometerREF Level keys MUTE/UNMUTE Solo keys for the channels R LS- SUB RSInstallation on PC Installation on MacIDP Soft Minimum requirementsVolume Control REF LEV. keysMonitor and Sub icons Bass Mgt Bass ManagementIDP Soft Preset List Recall presetsStore presets Locked symbol in Preset ListIDP Soft Network Upload Software to MonitorsSystem Setup Configuration Analog GainBNC Sync Monitor Assignment Calibrate Main MonitorsCalibrate Subwoofer Phase Range LFE Gain Range 0 to 14dBLFE Low Pass Filter Chained monitors Technical Specifications Precision 6 iDP System Master & SlavesTechnical Specifications- Precision 8 iDP Technical Specifications TS212 iDP Subwoofer TS112 iDP Subwoofer & iDPDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS212 iDP Grey/Silver Dimensions Precision TS112 iDP GreyIDP Display Messages System Delays Sample Rate Digital Input Analog Input Curves ExplainedSUB LFE Cables TC Link Standard Cat-5 cablesAES/EBU Standard cables Serial to Cat-5 cableDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December