Tannoy ACTIVE STUDIO MONITORS owner manual Setup when the monitors are connected

Page 25

SETUP when the monitors are connected

The following is a simple operational setup guide, which is carried out after the monitors are connected. The assumption is made that you will be navigating the menus via the LCD display on the master monitor. If you have purchased the optional software packages then refer to the iDP SOFTsection of this manual. If you are using the PC-iPadvanced installers package then refer to the user manual included with this package.

1.Connect the monitors

The monitors must be connected exactly as shown in the previous illustrated setup diagrams. Turn on the power on each monitor.

2.Set one monitor as the System Controller

Only one master monitor in the network can be set as the System Controller. Refer to the setup diagrams to determine which monitor this should be. To set the master monitor as the system controller make sure the TC LINK button on the rear panel is in the out position. All other master monitors in the setup must be set to operate as “slaves”, this is done by pressing the TC Link button to the “in” position. If you are changing the operational mode of the monitor you will be asked to confirm: -

“Mode changed set as slave?” or “Mode changed set as sys. Controller?” Confirm by pressing the “Enter” key on the Master Display

3.The gain setting is the first item in the main menu. The default setting in the main menu after switching on menu is –50dB. You may have to increase this value slightly in order to hear the pink noise when setting the monitor tasks (see 8.)

4.Setting Bass Management

The next item in the main menu is Bass Management. Select the required Mode:-

Off X-over 50Hz

X-over 80Hz X-over Ext 50Hz X-over Ext 80Hz X-over THX 80Hz X-over SC 120Hz

In stereo setups with subwoofers, the subs will only operate when the Bass Management is activated

5.Setup Menu

Go to Setup Menu and press Enter

25

Image 25
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Tannoy Dual Concentric Concept & Design PhilosophyUnpacking & Visual Checks High efficiency compact Switched Mode Power Supply SmpsTannoy WideBand SuperTweeter Preliminary Recommendation Speaker PlacementOrientation Master & Slave Concept Slave Monitor & Subwoofer Remote ControlInitializing the Network IDP Soft Software RemoteSlave/Subwoofer Master UnitSUB IDP Display Master General Setup ProcedureGeneral Setup Procedure SetupsAnalog Stereo Set-up With Mono Subs Stereo Digital Set-up With Mono Subs Analog Stereo Set-up With Stereo SubsDigital Set-up Analog Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Analog, Digital& 192kHz Alternative 7.1 Set-upConnecting Three Subs Connecting Two SubsStereo Set-up With Chains on L&R. Analog or Digital Dig/6 MasterSetup when the monitors are connected Reset All Settings Reset ProcedureSelect Setup Select Monitor TasksParameter Description Press Enter to access the Select ModeMain Display † PC-iPBass Management PhaseLFE Low Pass Filter LFE GainSetup Setup MenuSet Monitor Task External ClockLFE channel important Parameters available for the subwooferParameter Categories IDP Remote Volume potentiometer Preset 1/3 and 2/4 keysREF Level keys MUTE/UNMUTE Solo keys for the channels R LS- SUB RSInstallation on Mac Installation on PCIDP Soft Minimum requirementsREF LEV. keys Volume ControlMonitor and Sub icons Bass Mgt Bass ManagementRecall presets IDP Soft Preset ListStore presets Locked symbol in Preset ListUpload Software to Monitors IDP Soft NetworkAnalog Gain System Setup ConfigurationBNC Sync Calibrate Main Monitors Monitor AssignmentCalibrate Subwoofer LFE Gain Range 0 to 14dB Phase RangeLFE Low Pass Filter Chained monitors System Master & Slaves Technical Specifications Precision 6 iDPTechnical Specifications- Precision 8 iDP TS112 iDP Subwoofer & iDP Technical Specifications TS212 iDP SubwooferDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS112 iDP Grey Dimensions Precision TS212 iDP Grey/SilverIDP Display Messages Curves Explained System Delays Sample Rate Digital Input Analog InputSUB LFE TC Link Standard Cat-5 cables CablesAES/EBU Standard cables Serial to Cat-5 cableDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December