Setup Menu

Press ENTER to access sub-menus

Setup

Press ENTER to access select mode. Select mode is indicated by “ * ”

Press ENTER to confirm choice

Empty

Custom Stereo Analog Stereo Digital Stereo 192kHz Surround Analog Surround Digital Surround 192kHz 5.1 dig/6 Master

Set Monitor Task

For the System Controller/Master monitor to identify and operate all monitors in the setup, each monitor must be given one of the following tasks indicating function and position.

No Task

L SUB

L Front

R SUB

R Front

LS Chain

Center

RS Chain

(C) SUB

L Inner

L Sur

R Inner

R Sur

Custom 1-4 (Reserved for future use)

C Sur

 

Press ENTER to access task options

Use ARROW keys to select task

Press ENTER to confirm selected task

External Clock

Press ENTER to access sub-menus

BNC Sync On:

The monitor attempts to lock on the word Clock BNC.

BNC Sync Off:

The monitor will attempt to lock on the AES Input.

Calibrate Monitor

Press ENTER

Select monitor to calibrate using the ARROW keys

Press ENTER

29

Image 29
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Tannoy Dual Concentric Concept & Design PhilosophyTannoy WideBand SuperTweeter High efficiency compact Switched Mode Power Supply SmpsUnpacking & Visual Checks Orientation Speaker PlacementPreliminary Recommendation Master & Slave Concept Slave Monitor & Subwoofer Remote ControlInitializing the Network IDP Soft Software RemoteSlave/Subwoofer Master UnitSUB IDP Display Master General Setup ProcedureAnalog Stereo Set-up With Mono Subs SetupsGeneral Setup Procedure Stereo Digital Set-up With Mono Subs Analog Stereo Set-up With Stereo SubsDigital Set-up Analog Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Analog, Digital& 192kHz Alternative 7.1 Set-upConnecting Three Subs Connecting Two SubsStereo Set-up With Chains on L&R. Analog or Digital Dig/6 MasterSetup when the monitors are connected Reset All Settings Reset ProcedureSelect Setup Select Monitor TasksParameter Description Press Enter to access the Select ModeMain Display † PC-iPBass Management PhaseLFE Low Pass Filter LFE GainSetup Setup MenuSet Monitor Task External ClockLFE channel important Parameters available for the subwooferParameter Categories IDP Remote Volume potentiometer Preset 1/3 and 2/4 keysREF Level keys MUTE/UNMUTE Solo keys for the channels R LS- SUB RSInstallation on Mac Installation on PCIDP Soft Minimum requirementsREF LEV. keys Volume ControlMonitor and Sub icons Bass Mgt Bass ManagementRecall presets IDP Soft Preset ListStore presets Locked symbol in Preset ListUpload Software to Monitors IDP Soft NetworkBNC Sync System Setup ConfigurationAnalog Gain Calibrate Main Monitors Monitor AssignmentCalibrate Subwoofer LFE Low Pass Filter Phase RangeLFE Gain Range 0 to 14dB Chained monitors System Master & Slaves Technical Specifications Precision 6 iDPTechnical Specifications- Precision 8 iDP TS112 iDP Subwoofer & iDP Technical Specifications TS212 iDP SubwooferDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS112 iDP Grey Dimensions Precision TS212 iDP Grey/SilverIDP Display Messages Curves Explained System Delays Sample Rate Digital Input Analog InputSUB LFE TC Link Standard Cat-5 cables CablesAES/EBU Standard cables Serial to Cat-5 cableDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December