General Setup Procedure

Decide which Setup you are going to build.

Connect the Precision iDPmonitors exactly as shown on the following pages. Power up all monitors.

Set one of the Master-monitors as the System Controller as shown on the Setup diagrams. Leaving the TC LINK button on the rear panel in the OUT position does this.

NOTE: There can be only ONE System Controller in a setup.

After “power-up” the System scans all connected monitors every 5 seconds.

Set tasks for all monitors from the System Controller (unless you have iDP SOFT* or PC-iP**)

Enter Setup menu by pressing ENTER, ARROW DOWN, ENTER. Select the setup type you are using.

Press ENTER again and the System will generate Pink Noise in one of the monitors.

Select appropriate task for the monitor currently fed with Pink Noise using the ARROW keys and press ENTER to confirm.

Continue allocating tasks for all monitors in the system.

Your monitor system is now set up ready for calibration and fine-tuning.

*iDP SOFTis explained later in this Manual

**Precision iDP PC-iPhas it’s own dedicated user manual

Analog Stereo Set-up With Mono Sub(s)

The diagram shows how to connect a stereo set-up with one subwoofer. If you are using a standard stereo set up (no subwoofer) then simply omit the subwoofer.

The Left monitor is set as the System Controller by leaving out the TC Link button on the rear panel.

The Left master monitor receives both the left and right input signals via the analog input connectors.

The Right monitor and Sub receive audio and control via the output RJ45 TC Link connections on the Left (system controller) monitor.

When no Bass management is selected, no signal will be sent to the subwoofer.

When Bass management is selected, low frequency content from the left and right channels is extracted and sent to the subwoofer.

The iDPRemote, iDP SOFTor PC-iPcan be connected to any spare TC Link “out” connection.

! REMEMBER – To set a master monitor as the system controller the TC Link button on the rear panel MUST be in the out position.

16

Image 16
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Concept & Design Philosophy Tannoy Dual ConcentricUnpacking & Visual Checks High efficiency compact Switched Mode Power Supply SmpsTannoy WideBand SuperTweeter Preliminary Recommendation Speaker PlacementOrientation Master & Slave Concept Remote Control Slave Monitor & SubwooferInitializing the Network IDP Soft Software RemoteMaster Unit Slave/SubwooferSUB General Setup Procedure IDP Display MasterGeneral Setup Procedure SetupsAnalog Stereo Set-up With Mono Subs Analog Stereo Set-up With Stereo Subs Stereo Digital Set-up With Mono SubsAnalog Set-up Digital Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Alternative 7.1 Set-up Analog, Digital& 192kHzConnecting Two Subs Connecting Three SubsDig/6 Master Stereo Set-up With Chains on L&R. Analog or DigitalSetup when the monitors are connected Reset Procedure Reset All SettingsSelect Setup Select Monitor TasksPress Enter to access the Select Mode Parameter DescriptionMain Display † PC-iPPhase Bass ManagementLFE Low Pass Filter LFE GainSetup Menu SetupSet Monitor Task External ClockParameters available for the subwoofer LFE channel importantParameter Categories IDP Remote Preset 1/3 and 2/4 keys Volume potentiometerREF Level keys MUTE/UNMUTE Solo keys for the channels R LS- SUB RSInstallation on PC Installation on MacIDP Soft Minimum requirementsVolume Control REF LEV. keysMonitor and Sub icons Bass Mgt Bass ManagementIDP Soft Preset List Recall presetsStore presets Locked symbol in Preset ListIDP Soft Network Upload Software to MonitorsAnalog Gain System Setup ConfigurationBNC Sync Monitor Assignment Calibrate Main MonitorsCalibrate Subwoofer LFE Gain Range 0 to 14dB Phase RangeLFE Low Pass Filter Chained monitors Technical Specifications Precision 6 iDP System Master & SlavesTechnical Specifications- Precision 8 iDP Technical Specifications TS212 iDP Subwoofer TS112 iDP Subwoofer & iDPDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS212 iDP Grey/Silver Dimensions Precision TS112 iDP GreyIDP Display Messages System Delays Sample Rate Digital Input Analog Input Curves ExplainedSUB LFE Cables TC Link Standard Cat-5 cablesAES/EBU Standard cables Serial to Cat-5 cableDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December