A C T I V E S T U D I O M O N I T O R S
Setups
General Setup Procedure
Decide which Setup you are going to build.
Connect the Precision iDP™ monitors exactly as shown on the following pages. Power up all monitors.
Set one of the
NOTE: There can be only ONE System Controller in a setup.
After
Set tasks for all monitors from the System Controller (unless you have iDP SOFT™* or
Enter Setup menu by pressing ENTER, ARROW DOWN, ENTER. Select the setup type you are using.
Press ENTER again and the System will generate Pink Noise in one of the monitors.
Select appropriate task for the monitor currently fed with Pink Noise using the ARROW keys and press ENTER to confirm.
Continue allocating tasks for all monitors in the system.
Your monitor system is now set up ready for calibration and
*iDP SOFT™ is explained later in this Manual
**Precision iDP
Analog Stereo Set-up With Mono Sub(s)
The diagram shows how to connect a stereo
The Left monitor is set as the System Controller by leaving out the TC Link button on the rear panel.
The Left master monitor receives both the left and right input signals via the analog input connectors.
The Right monitor and Sub receive audio and control via the output RJ45 TC Link connections on the Left (system controller) monitor.
When no Bass management is selected, no signal will be sent to the subwoofer.
When Bass management is selected, low frequency content from the left and right channels is extracted and sent to the subwoofer.
The iDP™ Remote, iDP SOFT™ or
! REMEMBER – To set a master monitor as the system controller the TC Link button on the rear panel MUST be in the out position.