A C T I V E S T U D I O M O N I T O R S
6.Reset Procedure
Three different levels of “Reset” exist. For the three Reset levels all connected monitors will be affected. Select between the following reset options: -
The Reset functions are accessed by holding the ENTER key on the System Controller while powering up:
Clear Monitor Settings
All global and local parameters in connected monitors are reset. Preset and network settings are not affected.
Reset All Settings
This is a factory reset procedure that deletes all global and local parameter settings as well as preset and network settings.
The following reset procedure is found in the Setup menu:
Clear Setup for entire network
Select this reset procedure to clear all network settings.
7.Select Setup
You must define which type of setup you have: -
Empty Custom Stereo Analog Stereo Digital Stereo 192kHz Surround Analog Surround Digital Surround 192kHz 5.1 dig/6 Master
8.Select Monitor Tasks
Select first Monitor and press Enter.
Pink noise will be generated in one of the monitors in the setup.
Set Monitor Tasks
Choose the matching task for the position from where the pink noise is generated, for example, “Master L Front” Press Exit when complete.
9.External Source
BNC Input On - The monitor attempts to lock on the word Clock BNC connection. BNC Input Off - The monitor will attempt to lock on the AES Input.
26