6.Reset Procedure

Three different levels of “Reset” exist. For the three Reset levels all connected monitors will be affected. Select between the following reset options: -

The Reset functions are accessed by holding the ENTER key on the System Controller while powering up:

Clear Monitor Settings

All global and local parameters in connected monitors are reset. Preset and network settings are not affected.

Reset All Settings

This is a factory reset procedure that deletes all global and local parameter settings as well as preset and network settings.

The following reset procedure is found in the Setup menu:

Clear Setup for entire network

Select this reset procedure to clear all network settings.

7.Select Setup

You must define which type of setup you have: -

Empty Custom Stereo Analog Stereo Digital Stereo 192kHz Surround Analog Surround Digital Surround 192kHz 5.1 dig/6 Master

8.Select Monitor Tasks

Select first Monitor and press Enter.

Pink noise will be generated in one of the monitors in the setup.

Set Monitor Tasks

Choose the matching task for the position from where the pink noise is generated, for example, “Master L Front” Press Exit when complete.

9.External Source

BNC Input On - The monitor attempts to lock on the word Clock BNC connection. BNC Input Off - The monitor will attempt to lock on the AES Input.

26

Image 26
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Concept & Design Philosophy Tannoy Dual ConcentricTannoy WideBand SuperTweeter High efficiency compact Switched Mode Power Supply SmpsUnpacking & Visual Checks Orientation Speaker PlacementPreliminary Recommendation Master & Slave Concept Initializing the Network Remote ControlSlave Monitor & Subwoofer IDP Soft Software RemoteMaster Unit Slave/SubwooferSUB General Setup Procedure IDP Display MasterAnalog Stereo Set-up With Mono Subs SetupsGeneral Setup Procedure Analog Stereo Set-up With Stereo Subs Stereo Digital Set-up With Mono SubsAnalog Set-up Digital Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Alternative 7.1 Set-up Analog, Digital& 192kHzConnecting Two Subs Connecting Three SubsDig/6 Master Stereo Set-up With Chains on L&R. Analog or DigitalSetup when the monitors are connected Select Setup Reset ProcedureReset All Settings Select Monitor TasksMain Display Press Enter to access the Select ModeParameter Description † PC-iPLFE Low Pass Filter PhaseBass Management LFE GainSet Monitor Task Setup MenuSetup External ClockParameters available for the subwoofer LFE channel importantParameter Categories IDP Remote REF Level keys Preset 1/3 and 2/4 keysVolume potentiometer MUTE/UNMUTE Solo keys for the channels R LS- SUB RSIDP Soft Installation on PCInstallation on Mac Minimum requirementsMonitor and Sub icons Volume ControlREF LEV. keys Bass Mgt Bass ManagementStore presets IDP Soft Preset ListRecall presets Locked symbol in Preset ListIDP Soft Network Upload Software to MonitorsBNC Sync System Setup ConfigurationAnalog Gain Monitor Assignment Calibrate Main MonitorsCalibrate Subwoofer LFE Low Pass Filter Phase RangeLFE Gain Range 0 to 14dB Chained monitors Technical Specifications Precision 6 iDP System Master & SlavesTechnical Specifications- Precision 8 iDP Technical Specifications TS212 iDP Subwoofer TS112 iDP Subwoofer & iDPDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS212 iDP Grey/Silver Dimensions Precision TS112 iDP GreyIDP Display Messages System Delays Sample Rate Digital Input Analog Input Curves ExplainedSUB LFE AES/EBU Standard cables CablesTC Link Standard Cat-5 cables Serial to Cat-5 cableDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December