Tannoy ACTIVE STUDIO MONITORS owner manual IDP Display Master, General Setup Procedure

Page 15

The iDPDisplay - Master

EXIT

ENTER

INTERACTIVE DIGITAL PROGRAMMING

ENTER key

The ENTER key has two main functions: To enter the menus currently displayed.

To set the displayed parameter in Edit mode.

When a parameter can be edited via the CURSOR keys a H is set as the first character in front of the parameter.

EXIT key

The EXIT key is used to exit the current display and go to previous menu level.

CURSOR UP/DOWN key

These keys are used for navigating and adjusting parameter values.

The previous page illustrates how to navigate through parameters using the iDPdisplay.

Setting up - Introduction

To make your setup operate as intended correct cabling is essential. Choose one of the described setups and connect exactly as illustrated. The following section is a Quick-guide to get your system up and running.

For instructions on how to place and calibrate monitors please read pages 25-31.

Setup including Subwoofer:

To activate the subwoofer, please choose an appropriate crossover frequency in the Bass Management menu. To read more about Bass management and subwoofer placement, please refer to page 28.

General Setup Procedure

Decide which Setup you are going to build.

Connect monitors exactly according to the illustrations on the following pages.

Power up all monitors.

Set one of the Master-monitors as System Controller according to the Setup illustrations.

This is done by leaving the TC LINK button on the rear panel on OUT position.

NOTE: There can be only ONE System Controller in a setup.

After “power-up” the System scans all connected monitors every 5 seconds.

Set tasks for all monitors via the System Controller until via the following procedure: Enter Setup menu by pressing ENTER, ARROW DOWN, ENTER.

Select the setup type you are using.

Press ENTER again and the System will generate Pink Noise in one of the monitors. Select appropriate task for the monitor currently fed with Pink Noise using the ARROW keys and press ENTER to confirm.

Continue allocating tasks for all monitors in the system.

Your monitor system is now set up ready for calibration and fine-tuning.

These procedures are described on pages 29-31.

PLEASE NOTE: These setups will ONLY operate correctly if connected according to the illustrations!

15

Image 15
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Tannoy Dual Concentric Concept & Design PhilosophyHigh efficiency compact Switched Mode Power Supply Smps Unpacking & Visual ChecksTannoy WideBand SuperTweeter Speaker Placement Preliminary RecommendationOrientation Master & Slave Concept IDP Soft Software Remote Remote ControlSlave Monitor & Subwoofer Initializing the NetworkSlave/Subwoofer Master UnitSUB IDP Display Master General Setup ProcedureSetups General Setup ProcedureAnalog Stereo Set-up With Mono Subs Stereo Digital Set-up With Mono Subs Analog Stereo Set-up With Stereo SubsDigital Set-up Analog Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Analog, Digital& 192kHz Alternative 7.1 Set-upConnecting Three Subs Connecting Two SubsStereo Set-up With Chains on L&R. Analog or Digital Dig/6 MasterSetup when the monitors are connected Select Monitor Tasks Reset ProcedureReset All Settings Select Setup† PC-iP Press Enter to access the Select ModeParameter Description Main DisplayLFE Gain PhaseBass Management LFE Low Pass FilterExternal Clock Setup MenuSetup Set Monitor TaskLFE channel important Parameters available for the subwooferParameter Categories IDP Remote MUTE/UNMUTE Solo keys for the channels R LS- SUB RS Preset 1/3 and 2/4 keysVolume potentiometer REF Level keysMinimum requirements Installation on PCInstallation on Mac IDP SoftBass Mgt Bass Management Volume ControlREF LEV. keys Monitor and Sub iconsLocked symbol in Preset List IDP Soft Preset ListRecall presets Store presetsUpload Software to Monitors IDP Soft NetworkSystem Setup Configuration Analog GainBNC Sync Calibrate Main Monitors Monitor AssignmentCalibrate Subwoofer Phase Range LFE Gain Range 0 to 14dBLFE Low Pass Filter Chained monitors System Master & Slaves Technical Specifications Precision 6 iDPTechnical Specifications- Precision 8 iDP TS112 iDP Subwoofer & iDP Technical Specifications TS212 iDP SubwooferDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS112 iDP Grey Dimensions Precision TS212 iDP Grey/SilverIDP Display Messages Curves Explained System Delays Sample Rate Digital Input Analog InputSUB LFE Serial to Cat-5 cable CablesTC Link Standard Cat-5 cables AES/EBU Standard cablesDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December