Tannoy ACTIVE STUDIO MONITORS owner manual Digital 192kHz Set-up

Page 19

5.1 Digital 192kHz Set-up

The diagram shows how to connect a 5.1 digital set-up at 192khz.

All Master monitors require installed digital I/O cards.

AES signal is fed to inputs 2&3 of these cards.

The Centre monitor is set as the System Controller by leaving out the TC Link button on the rear panel.

The Centre monitor receives audio for both centre & LFE channels via the AES input connectors (input 2 for Centre & input 3 for Sub).

The LFE subwoofer is fed via the RJ-45 connection from the left monitor.

RJ45 Network connections from the Centre monitor to the Left & Right monitors are required.

The Left Monitor receives audio for both Left & LS channels via the AES input connector (input 2 for Left & input 3 for LS). The LS monitor is fed via the RJ-45 connection from the Left monitor.

The Right Monitor receives audio for both Right & RS channels via the AES input connector (input 2 for Left & input 3 for RS). The RS monitor is fed via the RJ-45 connection from the Left monitor.

Clock MUST be sent on the AES connection feeding the Centre/LFE channels (or on BNC).

When no Bass management is selected, only the LFE signal will be sent to the subwoofer.

When Bass management is selected, low frequency content from the 5 main channels is extracted and sent to the subwoofer where it is summed with the LFE channel

The iDPRemote, iDP SOFTor PC-iPcan be connected to any spare TC Link “out” connection.

! REMEMBER – To set a master monitor as the system controller the TC Link button on the rear panel MUST be in the out position.

6.1 Analog Set-up

The diagram shows how to connect a 6.1 analog set-up.

The Centre monitor is set as the System Controller by leaving out the TC Link button on the rear panel.

The Centre monitor receives audio for both centre (input 1) & LFE channels (input 2) via the analog input connectors. The LFE subwoofer is fed via the RJ-45 connection from the left monitor.

RJ45 Network connections from the Centre monitor to the Left & Right monitors are required.

The Left Monitor receives audio for both Left (input 1) & LS channels (input 2) via the analog input connectors. The LS monitor is fed via the RJ-45 connection from the Left monitor. The CS monitor is fed via the RJ-45 connector from the LS monitor.

Audio for the CS monitor is fed to analog input connector 1.

The Right Monitor receives audio for both Right (input 1) & RS channels (input 2) via the analog input connectors. The RS monitor is fed via the RJ-45 connection from the Right monitor.

When no Bass management is selected, only the LFE signal will be sent to the subwoofer.

When Bass management is selected, low frequency content from the

5 main channels is extracted and sent to the subwoofer where it is summed with the LFE channel. (Only LF, Center, RF, LS, and RS contribute to the bass management signal.)

The iDPRemote, iDP SOFTor PC-iPcan be connected to any spare TC Link “out” connection.

! REMEMBER – To set a master monitor as the system controller the TC Link button on the rear panel MUST be in the out position.

19

Image 19
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Tannoy Dual Concentric Concept & Design PhilosophyUnpacking & Visual Checks High efficiency compact Switched Mode Power Supply SmpsTannoy WideBand SuperTweeter Preliminary Recommendation Speaker PlacementOrientation Master & Slave Concept IDP Soft Software Remote Remote ControlSlave Monitor & Subwoofer Initializing the NetworkSlave/Subwoofer Master UnitSUB IDP Display Master General Setup ProcedureGeneral Setup Procedure SetupsAnalog Stereo Set-up With Mono Subs Stereo Digital Set-up With Mono Subs Analog Stereo Set-up With Stereo SubsDigital Set-up Analog Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Analog, Digital& 192kHz Alternative 7.1 Set-upConnecting Three Subs Connecting Two SubsStereo Set-up With Chains on L&R. Analog or Digital Dig/6 MasterSetup when the monitors are connected Select Monitor Tasks Reset ProcedureReset All Settings Select Setup† PC-iP Press Enter to access the Select ModeParameter Description Main DisplayLFE Gain PhaseBass Management LFE Low Pass FilterExternal Clock Setup MenuSetup Set Monitor TaskLFE channel important Parameters available for the subwooferParameter Categories IDP Remote MUTE/UNMUTE Solo keys for the channels R LS- SUB RS Preset 1/3 and 2/4 keysVolume potentiometer REF Level keysMinimum requirements Installation on PCInstallation on Mac IDP SoftBass Mgt Bass Management Volume ControlREF LEV. keys Monitor and Sub iconsLocked symbol in Preset List IDP Soft Preset ListRecall presets Store presetsUpload Software to Monitors IDP Soft NetworkAnalog Gain System Setup ConfigurationBNC Sync Calibrate Main Monitors Monitor AssignmentCalibrate Subwoofer LFE Gain Range 0 to 14dB Phase RangeLFE Low Pass Filter Chained monitors System Master & Slaves Technical Specifications Precision 6 iDPTechnical Specifications- Precision 8 iDP TS112 iDP Subwoofer & iDP Technical Specifications TS212 iDP SubwooferDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS112 iDP Grey Dimensions Precision TS212 iDP Grey/SilverIDP Display Messages Curves Explained System Delays Sample Rate Digital Input Analog InputSUB LFE Serial to Cat-5 cable CablesTC Link Standard Cat-5 cables AES/EBU Standard cablesDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December