5.1 Dig/6 - Master

The diagram shows how to connect a 5.1 digital set-up using a single master unit. The set-up requires one master monitor with the Digital AES\EBU input card installed, four slave monitors and one subwoofer.

The Centre monitor is set as the System Controller by leaving out the TC Link button on the rear panel.

The Centre monitor receives all six channels on the three AES\EBU connections:-

Audio for the Centre and LFE channels are connected to the monitors Digital IN connector.

Audio for the Left and Right channels are connected to the monitors Digital IN No.2 connection on the I/0 card.

Audio for the LS and RS channels are connected to the monitors Digital IN No.3 connection on the I/0 card.

RJ45 Network connections from the Centre monitor to the Left,

LS & subwoofer are required. Network connections from the Left to Right, and LS to RS are required.

Clock MUST be sent on the AES/EBU connection feeding the Centre/LFE channels (or on BNC)

When no Bass management is selected, only the LFE signal will be sent to the subwoofer.

When Bass management is selected, low frequency content from the

5 main channels is extracted and sent to the subwoofer where it is summed with the LFE channel

The iDPRemote, iDP SOFTor PC-iPcan be connected to any spare TC Link “out” connection.

! REMEMBER – To set a master monitor as the system controller the TC Link button on the rear panel MUST be in the out position.

Stereo Set-up With Chains on L&R. Analog or Digital

This diagram shows how to connect a stereo setup with chains on Left and Right. The chained monitors are fed with the same signal as the front L&R monitors. This is the type of setup you would use if you are alternating between a set of main (Precision 8 iDP) and nearfield (Precision 6 iDP) monitors. With this type of set-up only one master is required.

The Left monitor is set as the System Controller by leaving out the TC Link button on the rear panel.

The Left master monitor receives both the left and right input signals via the analog or AES\EBU input connector(s).

The Right monitor receives audio and control via the output RJ45 TC Link connections on the Left (system controller) monitor.

The Left monitor receives audio and control via the output RJ45 TC Link connector on the Left (system controller) monitor.

The Right monitor receives audio and control via the output RJ45 TC Link connector on the Right monitor.

The iDPRemote, iDP SOFTor PC-iPcan be connected to any spare TC Link “out” connection.

! REMEMBER – To set a master monitor as the system controller the TC Link button on the rear panel MUST be in the out position.

The “Chained” option is also achievable in all surround formats

24

Image 24
Contents Owners M a N U a L Page Important Safety Instructions Important Safety Instructions Quick Setup Guide T I V E S T U D I O M O N I T O R S Introduction Concept & Design Philosophy Tannoy Dual ConcentricHigh efficiency compact Switched Mode Power Supply Smps Unpacking & Visual ChecksTannoy WideBand SuperTweeter Speaker Placement Preliminary RecommendationOrientation Master & Slave Concept Remote Control Slave Monitor & SubwooferInitializing the Network IDP Soft Software RemoteMaster Unit Slave/SubwooferSUB General Setup Procedure IDP Display MasterSetups General Setup ProcedureAnalog Stereo Set-up With Mono Subs Analog Stereo Set-up With Stereo Subs Stereo Digital Set-up With Mono SubsAnalog Set-up Digital Set-upDigital 192kHz Set-up Digital Set-up Analog Set-up Alternative 7.1 Set-up Analog, Digital& 192kHzConnecting Two Subs Connecting Three SubsDig/6 Master Stereo Set-up With Chains on L&R. Analog or DigitalSetup when the monitors are connected Reset Procedure Reset All SettingsSelect Setup Select Monitor TasksPress Enter to access the Select Mode Parameter DescriptionMain Display † PC-iPPhase Bass ManagementLFE Low Pass Filter LFE GainSetup Menu SetupSet Monitor Task External ClockParameters available for the subwoofer LFE channel importantParameter Categories IDP Remote Preset 1/3 and 2/4 keys Volume potentiometerREF Level keys MUTE/UNMUTE Solo keys for the channels R LS- SUB RSInstallation on PC Installation on MacIDP Soft Minimum requirementsVolume Control REF LEV. keysMonitor and Sub icons Bass Mgt Bass ManagementIDP Soft Preset List Recall presetsStore presets Locked symbol in Preset ListIDP Soft Network Upload Software to MonitorsSystem Setup Configuration Analog GainBNC Sync Monitor Assignment Calibrate Main MonitorsCalibrate Subwoofer Phase Range LFE Gain Range 0 to 14dBLFE Low Pass Filter Chained monitors Technical Specifications Precision 6 iDP System Master & SlavesTechnical Specifications- Precision 8 iDP Technical Specifications TS212 iDP Subwoofer TS112 iDP Subwoofer & iDPDimensions Precision 6 iDP Dimensions Precision 8 iDP Dimensions Precision TS212 iDP Grey/Silver Dimensions Precision TS112 iDP GreyIDP Display Messages System Delays Sample Rate Digital Input Analog Input Curves ExplainedSUB LFE Cables TC Link Standard Cat-5 cablesAES/EBU Standard cables Serial to Cat-5 cableDeclaration Of Conformity Warranty Page Issue Software Version 1.53 Part No GH 01 December