MGE UPS Systems 40-150kVA user manual Options and Accessories

Page 23

Installation and User Manual

1.4Options and Accessories

Options are available for the Comet 40-150kVA UPS’s. Most options must be specified at the time of the original order for factory installation. Some options can be field installed; contact your MGE Sales Representative for further information.

Auxiliary Cabinet

The auxiliary cabinet may provide one or both of the following options: an input

 

 

bypass step up/down transformer, and an output distribution panel. An output

 

 

distribution panel provides connection points for distribution of AC power to

 

 

computers and other equipment. Also available are external maintenance bypass

 

 

cabinets.

Extended Battery Cabinets

Up to two Extended Battery Cabinets are available to provide extra back-up time

 

 

during power outage.

1.4.1

UPS Options

 

These options are internal to the Comet.

Isolated Redundant System This option is used to connect the static switch and maintenance bypass to a reserve UPS source for redundancy

UPS without Standard

This option allows for the connection of a customer-supplied battery system to

Battery Subsystem

the UPS.

(External Batteries)

 

 

Communication Options

Communication options may be used simultaneously on the Comet, thus

 

enabling communication with a wide number of computers and control devices.

Monitor Plus

Mini terminal for control and display of system parameters. This option can be in-

 

stalled locally or remotely.

Contact 5

This option offers communication of five different signals via dry relay contacts:

 

Load on UPS

 

Load on Bypass

 

Operation on Battery

 

Low Battery Shutdown Warning

 

Summary Alarm (major or minor faults)

U-Talk

This option manages an RS232 serial interface using an ASCII protocol.

JBUS/RS485

This option enables remote monitoring of the Comet.

1.4.2Software and Communication Package

Solution-Pac

Automatic file shutdown during power outage or severe brownout for stand-

 

 

alone systems.

 

Automatic file shutdown for network servers plus additional monitoring and

 

 

network communication functions.

 

Automatic file shutdown with user-friendly control panel and advanced

 

 

decision-making functions for Windows. This package includes an easy to

 

 

use load.

86-160310-00 E00

System Description and Specifications

1 — 11

Image 23
Contents Comet 40-150kVA Page Revision History CometComet 40-150kVA Important Safety InstructionsSpecial Precautions Certification Standards Three Phase UPSSafety of Persons Product SafetyThis page left blank intentionally Contents Operation MaintenanceTables MGE Warranty & Proprietary Rights for Three Phase ProductsWarranty and Product Registration Customer Care Center Three Phase ProductsUPS Serial Number Battery Serial Number This page left blank intentionally 86-160310-00 E00 Section Descriptions Comet 40-150kVA Symbol UsageGeneral Description System Description and SpecificationsScope Single Line Diagram for the Comet 40-80kVA Major Components Detail Behind Item Rear View of the Comet 40-80kVA FU1-FU21 Control Fuses TOP Conduit Landing for Cable Access to Pcas Specifications DC Ratings Battery voltage 25 C PhasesWires Power factorAltitude Environmental Specifications Temperature6 DB15 Connector Pinouts and Designations HumidityOptions and Accessories Chaptername This page left blank intentionally For assistance InstallationReceiving HandlingEnvironmental Prerequisite to InstallationStorage May adversely affect lifeElectrical Short circuit when the unit is working on Static SwitchProper trip settings MechanicalConnections Installation ProceduresAC Output BatteryChaptername This page left blank intentionally Operation Power FlowPower Flow, For Normal Operation Power Flow, For On Battery OperationPower Flow, For Bypass Operation Graphical User Interface, Controls and IndicatorsComet Front Panel GUI, Controls and Indicators Fault Reset Emergency Power OffFault LED Battery Status LEDPreliminary Checks Startup ProceduresInverter Manual Startup Return to AC Power Operating ProceduresOperation on Battery Power Battery DurationOutput Current Overload Curve Forced Transfer Emergency Shutdown Using EPO/REPOMaintenance Bypass Move the fan control switch SR2 to the OFF position Inverter Shutdown Shutdown ProceduresAlarms Powering DownPreventive Maintenance MaintenanceBattery Safety Level Description Replacement PartsApplicable within the United States, Canada and Mexico Product Information Warranty Extension Warranty+User Information Return Policy for Repair of Three Phase Products RGA MGE Customer Care Center Three Phase ProductsTechnical Support and Product Services Scheduling Field Service Engineer SupportComet 40-150kVA Term used Definition / Meaning GlossaryFCC NEC This page left blank intentionally Reorder Form Scenic Avenue Costa Mesa, CA Page Page Contact MGE