APC 6739380EN/JC user manual Contents

Page 3

Contents

Introduction

 

System performance

5

System description

5

Different types of MGETM GalaxyTM 6000 systems

6

Isolation and protection devices

8

Main operating modes

9

Description of MGETMGalaxyTM 6000 cubicles

 

Inverter cubicle

13

Battery cubicle

14

Static Switch Cubicle

15

External maintenance bypass cubicle

15

Control panel

 

Visible control panel

16

Hidden control panel

18

Start-up

 

System start-up

20

Start-up of a unit

22

Shutdown

 

Shutdown of a unit

24

System shutdown

25

Buzzer reset

26

Alarms

 

Maintenance bypass

27

Environment information

 

Standard information "Media Contacts 9"

28

"LED" signalling box

29

Additional information "Media Contacts 15"

29

Maintenance

 

Maintenance configuration

31

Battery maintenance

33

Autodiagnostics

34

Visual check

34

Functional check

34

Training center

34

"Monitor" alphanumeric display

 

General

36

Control panel

36

Lights 1 to 8

37

Alarm display and buzzer reset

38

Measurement system

41

Voltage measurements

42

Current measurements

42

Frequency and power measurements

43

Battery measurements

43

Inverter "On/Off" commands

45

Language, display contrast and buzzer volume settings

45

Display system configuration

46

6739380EN/JC - Page 3

Image 3
Contents Mgetm GalaxyTM 2 6739380EN/JC Contents Options System may also include IntroductionSystem performance System descriptionUp to 4 UPS identical ratings can be parallel-connected Different types of MGETMGalaxyTM 6000 systemsFrequency converter with battery backup power figure Static Switch Cubicle Isolation and protection devicesUPS or converter cubicles Main operating modes Normal operationOperation with Mains 1 down Battery time Operation with Mains 1 restoredBattery charge cycle Installation with an engine generator set Example of an installation with an engine generator setUPS shutdown or overload Overload curve Output voltage quality and continuityFrequency converters without redundancy Frequency converters with redundancy450 to 500kVA UPS or frequency converter Description of MGETMGalaxyTM 6000 cubiclesInverter cubicle 250 to 400kVA UPS or frequency converterBattery cubicle KVA UPSFor a 250 to 300kVA UPS External maintenance bypass cubicle Static Switch CubicleMgetm GalaxyTM 6000 control panel Visible control panel Static Switch CubicleControl panel Visible control panelLoad protected light Buzzer Operating problem lightBattery operation light Load not protected lightHidden control panel Light I battery discharged Light F battery temperature outside tolerancesLight G battery charging Light H inverter faultMulti-bypass modular UPS Start-upSystem start-up Single-unit or modular UPSGalaxy UPS Modular UPS with external maintenance bypassStart-up of a rectifier/charger Parallel UPS systems with a Static Switch CubicleStart-up of a unit Frequency convertersFrequency converter or multi-bypass UPS Frequency converter without a batteryStart-up of an inverter Single-unit or modular UPS systemShutdown of an rectifier/charger ShutdownShutdown of a unit Shutdown of an inverterModular UPS External maintenance bypassSystem shutdown Single-unit or single modularWith Mains Buzzer resetParallel UPSs with SSC No MainsMaintenance bypass AlarmsStandard information Media Contacts Signal receptionSignal transmission Environment informationLED signalling box optional Additional information Media Contacts 15 optionalAdditional remote transmission board 30 6739380EN/JC Maintenance Maintenance configurationSingle-unit or single modular UPS figure Isolate the UPSs Frequency converter or parallel UPS with SSCVented lead-acid batteries Battery maintenanceAutodiagnostics Visual checkFunctional check Training centers Monitor alphanumeric display GeneralDisplay Lights 1 to Green lightsRed lights Alarm display and buzzer reset List of general alarmsDisplay of alarms Mains 2 Problem Check Frequency List of secondary alarmsBattery is currently being recharged Measurement system Display of current measurements Voltage measurementsCurrent measurements Display of voltage measurementsDisplay of battery measurements Frequency and power measurementsBattery measurements Display of power and frequency measurementsBattery test see figure opposite Display of the settings selection screens Inverter On/Off commandsLanguage, display contrast and buzzer volume settings Display for the inverter On/Off commandsDisplay system configuration Display system configurationTele-Monitor remote indications unit LED signalling boxOptions Media Contacts 15 additional auxiliary transmissionHarmonics filter and power factor improvement Vision displayRemote vision display Mgetm GalaxyTM 6000UPSs standard input rectifier-charger Battery Temperature MonitorDouble bridge rectifier-charger Empty cubicles50 6739380EN/JC