2.PRINTER SETUP
ENGLISH VERSION
2.13 Threshold Setting
2.13Threshold Setting (Cont.)
(3) Press the [PAUSE] key until the target sensor type is displayed.
<3>ADJUST SET | Black Mark Sensor | |||
THRESHOLD<R>1.0V | ||||
| ||||
|
|
|
| |
| [PAUSE] |
| ||
<3> ADJUST SET | Feed Gap Sensor | |||
THRESHOLD<T>1.4V |
|
NOTE:
Pressing the [FEED] key one time causes a
(4)Set a threshold voltage (calculated in Sensor Adjustment Menu) by using the [FEED] or [RESTART] key, as shown below.
Threshold voltage = Midpoint between voltage at a print area and voltage at a gap/black mark
Black Mark Sensor |
| Feed Gap Sensor |
THRESHOLD<R>4.0V |
| THRESHOLD<T>4.0V |
THRESHOLD<R>3.9V | [RESTART] | THRESHOLD<T>3.9V |
THRESHOLD<R>3.8V |
| THRESHOLD<T>3.8V |
THRESHOLD<R>0.1V | [FEED] | THRESHOLD<T>0.1V |
THRESHOLD<R>0.0V |
| THRESHOLD<T>0.0V |
(5)After choosing a threshold voltage, press the [PAUSE] key.
(6)To check for a proper operation, issue the