Casio P460 manual Chassis Component Location, Key

Page 20

Chapter 3 Avaya P460 Chassis and Module Installation

Chassis Component Location

Figure 3.1 shows the positions of the components in the P460 chassis.

Figure 3.1 The Avaya P460 Switch – Component Location

1

2

4

3

Key

1Supervisor modules

2I/O Modules

3PSUs

4Fan module

6

Avaya P460 Installation and Maintenance Guide

Image 20
Contents Avaya P460 Page Contents Table of Contents Radius Ieee Ietf List of Tables List of Tables Avaya P460 Installation and Maintenance Guide List of Figures Page Power Supplies Before you Install the Avaya P460Safety Information FCC Notice Conventions Used in the DocumentationCLI Conventions WarrantyAvaya Support Preface Avaya P460 Installation and Maintenance Guide Avaya P460 Overview IntroductionAvaya P460 Key Features High AvailabilityFlexibility Management and MonitoringAvaya P460 Chassis and Module Installation Operating SafetyRequired Tools Environmental PrerequisitesAC Power Requirements Chassis Component Location KeyInstalling the P460 on a Table Top Rack Mounting140 mm P460 Rack mounting procedure Positioning the rack-mounting bracketsCable Guide Installation Installing the Cable GuidePSU Power Supply Unit Installation Fan Module Replacement or Installation Avaya P460 Switch Fan Module LocationInstalling the Avaya P460 Fan Module Supervisor Module Installation Location of the Avaya P460 Supervisor ModulesInstalling the P460 Supervisor Module Module Installation 10 Lcoation of Avaya P460 I/O ModulesModule Installation Procedure 11 I/O Module Component Location12 Installing P460 I/O Modules Installing a PSU Turning on the Avaya P460Powering Up Inserting an Additional PSUTurning on a Chassis with a Supervisor Module Only Turning on a Chassis with no ModulesIf there are two PSUs Removing or Switching off a PSUIf there is one PSU If there are three PSUs Power Management Power Management ProcessI/O Module Power Management Process M460ML-SPV LEDs Avaya P460 PanelsM460ML-SPV Panel PWR ACT LED and OPR LED Summary Starting Point After Power-up or Reset Function LEDsLNK LAG M460ML-SPV Supervisor Module Ports M460ML-SPV Left and Right PushbuttonsEth Port Outband Connection RS-232 Port Sideband ConnectionM460ML-SPV ASB Alternate Software Bank Pushbutton P460 Supervisor Module ASB PushbuttonPower Supply Panel Page M460ML-SPV Supervisor Module Modes Maximizing Avaya P460 AvailabilityM460ML-SPV Supervisor Module Redundancy Synchronizing the Supervisor Modules Manually Configuration File Synchronization Following screen capture shows the processMaximizing Avaya P460 Availability Redundant Power Supplies P460 show environment powerCalculating the Power Budget Sample Power Budget CalculationEstablishing Switch Access Establishing a Console Connection with the P460Establishing a Telnet Connection with the Switch Inband Inband Interface Connection CLI CommandsEstablishing a Telnet Connection with the Switch Outband M460ML-SPV Supervisor Module Fast Ethernet Console PortOutband Interface Connection CLI Commands Redundant Outband Connections Redundant Outband ConnectionsSideband PPP Interface CLI Commands OverviewSetting Up Sideband PPP Connection Configuration Set interface ppp ipaddrnet-maskPage Avaya Msnm P460 Manager Running the Avaya Msnm P460 Manager WelcomeP460 Device Manager Installing the Java Plug-in Installing from the P460 Documentation and Utilities CDInstall from the Avaya Web Site Install from your Local Web SiteDocumentation Page Local User Accounts User AuthenticationAccess Levels Local User Account CLI Commands Radius Introduction to RadiusIllustrates the Radius authentication procedure Radius CLI CommandsUser Authentication Allowed Manager CLI Commands Allowed ManagersConfiguration Defaults Default System ParametersConfiguration Default CLI Commands Basic Switch Configuration Operating parameters System Parameter ConfigurationIdentifying the system Feature Activation Time Parameter ConfigurationFeature License Configuration Obtaining a License Key Click Generate Feature License CLI Commands Activating a Routing License KeyTroubleshooting the Installation Powering up the ChassisPowering up the Supervisor Modules Powering up the Fan ModulePowering up the I/O Modules Supervisor Module does not Boot Page Maintenance One Supervisor Module in the SwitchTwo Supervisor Modules in the Switch Replacing I/O ModulesPreferred Bank Firmware DownloadIntroduction Configuration Management CLI Commands Configuration File ManagementFirmware Download CLI Commands Page Standards IeeeRouting Specifications PhysicalEnvironmental Power RequirementsSafety Transportation EMC EmissionsImmunity Catalog Numbers Avaya P460 Catalog Numbers