One of the SPVs can operate as Standby automatically only if both of the following conditions are fulfilled:

The current chassis is the last one in which you inserted this SPV

The current running SW images are the same version

Firmware Download

You can perform software download using the copy tftp command (see page 26 of the Avaya P460 Reference Guide) or the Avaya Software Update Manager (part of the Avaya™ Multiservice Network Manager Suite).

You can obtain the latest firmware from the Avaya support site at http://www.support.avaya.com

Introduction

Each P460 Supervisor module has two firmware image banks (“A” and “B”) and one Device Manager (Embedded Web) bank.

The download is on a per-chassis basis and the firmware is automatically loaded into the standby Supervisor module (if configured) in addition to the active Supervisor module.

Firmware is not downloaded to a halted Supervisor module.

You download the firmware to each bank separately via the CLI. The download progress is shown on the screen.

Preferred Bank

You can choose which firmware bank to boot from (preferred bank) using the set boot bank command.

Changing the preferred bank affects both SPVs.

Booting from the Alternate Firmware Bank

Push the ASB button together with both function switches on the SPV front panel to boot from the alternate SW bank.

If the SPVs were running in a Active-Standby configuration and ASB caused SW incompatibility between the SPVs, the Standby SPV will switch to Halted mode.

74

Avaya P460 Installation and Maintenance Guide

Image 88
Contents Avaya P460 Page Contents Table of Contents Radius Ieee Ietf List of Tables List of Tables Avaya P460 Installation and Maintenance Guide List of Figures Page Safety Information Before you Install the Avaya P460Power Supplies FCC Notice Conventions Used in the DocumentationAvaya Support WarrantyCLI Conventions Preface Avaya P460 Installation and Maintenance Guide Avaya P460 Overview IntroductionAvaya P460 Key Features High AvailabilityFlexibility Management and MonitoringAvaya P460 Chassis and Module Installation Operating SafetyRequired Tools Environmental PrerequisitesAC Power Requirements Chassis Component Location KeyInstalling the P460 on a Table Top Rack Mounting140 mm P460 Rack mounting procedure Positioning the rack-mounting bracketsCable Guide Installation Installing the Cable GuidePSU Power Supply Unit Installation Fan Module Replacement or Installation Avaya P460 Switch Fan Module LocationInstalling the Avaya P460 Fan Module Supervisor Module Installation Location of the Avaya P460 Supervisor ModulesInstalling the P460 Supervisor Module Module Installation 10 Lcoation of Avaya P460 I/O ModulesModule Installation Procedure 11 I/O Module Component Location12 Installing P460 I/O Modules Installing a PSU Turning on the Avaya P460Powering Up Inserting an Additional PSUTurning on a Chassis with a Supervisor Module Only Turning on a Chassis with no ModulesIf there is one PSU Removing or Switching off a PSUIf there are two PSUs If there are three PSUs Power Management Power Management ProcessI/O Module Power Management Process M460ML-SPV Panel Avaya P460 PanelsM460ML-SPV LEDs PWR ACT LED and OPR LED Summary Starting Point After Power-up or Reset Function LEDsLNK LAG M460ML-SPV Supervisor Module Ports M460ML-SPV Left and Right PushbuttonsEth Port Outband Connection RS-232 Port Sideband ConnectionM460ML-SPV ASB Alternate Software Bank Pushbutton P460 Supervisor Module ASB PushbuttonPower Supply Panel Page M460ML-SPV Supervisor Module Redundancy Maximizing Avaya P460 AvailabilityM460ML-SPV Supervisor Module Modes Synchronizing the Supervisor Modules Manually Configuration File Synchronization Following screen capture shows the processMaximizing Avaya P460 Availability Redundant Power Supplies P460 show environment powerCalculating the Power Budget Sample Power Budget CalculationEstablishing Switch Access Establishing a Console Connection with the P460Establishing a Telnet Connection with the Switch Inband Inband Interface Connection CLI CommandsEstablishing a Telnet Connection with the Switch Outband M460ML-SPV Supervisor Module Fast Ethernet Console PortOutband Interface Connection CLI Commands Redundant Outband Connections Redundant Outband ConnectionsSideband PPP Interface CLI Commands OverviewSetting Up Sideband PPP Connection Configuration Set interface ppp ipaddrnet-maskPage Avaya Msnm P460 Manager Running the Avaya Msnm P460 Manager WelcomeP460 Device Manager Installing the Java Plug-in Installing from the P460 Documentation and Utilities CDInstall from the Avaya Web Site Install from your Local Web SiteDocumentation Page Access Levels User AuthenticationLocal User Accounts Local User Account CLI Commands Radius Introduction to RadiusIllustrates the Radius authentication procedure Radius CLI CommandsUser Authentication Allowed Manager CLI Commands Allowed ManagersConfiguration Defaults Default System ParametersConfiguration Default CLI Commands Basic Switch Configuration Identifying the system System Parameter ConfigurationOperating parameters Feature License Configuration Time Parameter ConfigurationFeature Activation Obtaining a License Key Click Generate Feature License CLI Commands Activating a Routing License KeyTroubleshooting the Installation Powering up the ChassisPowering up the Supervisor Modules Powering up the Fan ModulePowering up the I/O Modules Supervisor Module does not Boot Page Maintenance One Supervisor Module in the SwitchTwo Supervisor Modules in the Switch Replacing I/O ModulesIntroduction Firmware DownloadPreferred Bank Firmware Download CLI Commands Configuration File ManagementConfiguration Management CLI Commands Page Standards IeeeRouting Specifications PhysicalSafety Power RequirementsEnvironmental Immunity EMC EmissionsTransportation Catalog Numbers Avaya P460 Catalog Numbers