Casio P460 manual Overview, Sideband PPP Interface CLI Commands

Page 60

Chapter 7 Establishing Switch Access

Establishing a PPP via Modem Connection with the P460 (Sideband)

Overview

The Point-to-Point Protocol (PPP) provides a Layer 2 method for transporting multi- protocol datagrams over point-to-point links. Here only IP datagrams will be exchanged, over a RS232 serial connection, between the P460 supervisor module and a remote peer (such as Ethernet) via a modem and the telephone lines. This provides remote access the sideband management interface of a P460 via a modem.

Sideband (PPP) Interface CLI Commands

In order to...

Use the following command...

 

 

 

 

Configure the device ppp interface

set interface ppp

and control a PPP session

 

 

 

Configure the shared secret used in

set ppp chap-secret

PPP sessions with CHAP

 

authentication

 

 

 

Set the time after which the system

set ppp incoming timeout

automatically disconnects an idle

 

PPP incoming session

 

 

 

Define the PPP authentication

set ppp authentication incoming

method

 

 

 

Set the baud rate used in PPP

set ppp baud-rate

sessions

 

 

 

Display the PPP parameters of the

show ppp session

active PPP session.

 

 

 

Display the authentication method

show ppp authentication

used for PPP sessions

 

 

 

Display the time after which the

show ppp incoming timeout

system automatically disconnects

 

an idle PPP incoming session

 

 

 

Display the baud rate used in PPP

show ppp baud-rate

sessions

 

 

 

Display the ppp configuration

show ppp configuration

 

 

46

Avaya P460 Installation and Maintenance Guide

Image 60
Contents Avaya P460 Page Contents Table of Contents Radius Ieee Ietf List of Tables List of Tables Avaya P460 Installation and Maintenance Guide List of Figures Page Before you Install the Avaya P460 Safety InformationPower Supplies FCC Notice Conventions Used in the DocumentationWarranty Avaya SupportCLI Conventions Preface Avaya P460 Installation and Maintenance Guide Avaya P460 Overview IntroductionAvaya P460 Key Features High AvailabilityFlexibility Management and MonitoringAvaya P460 Chassis and Module Installation Operating SafetyRequired Tools Environmental PrerequisitesAC Power Requirements Chassis Component Location KeyInstalling the P460 on a Table Top Rack Mounting140 mm P460 Rack mounting procedure Positioning the rack-mounting bracketsCable Guide Installation Installing the Cable GuidePSU Power Supply Unit Installation Fan Module Replacement or Installation Avaya P460 Switch Fan Module LocationInstalling the Avaya P460 Fan Module Supervisor Module Installation Location of the Avaya P460 Supervisor ModulesInstalling the P460 Supervisor Module Module Installation 10 Lcoation of Avaya P460 I/O ModulesModule Installation Procedure 11 I/O Module Component Location12 Installing P460 I/O Modules Installing a PSU Turning on the Avaya P460Powering Up Inserting an Additional PSUTurning on a Chassis with a Supervisor Module Only Turning on a Chassis with no ModulesRemoving or Switching off a PSU If there is one PSUIf there are two PSUs If there are three PSUs Power Management Power Management ProcessI/O Module Power Management Process Avaya P460 Panels M460ML-SPV PanelM460ML-SPV LEDs PWR ACT LED and OPR LED Summary Starting Point After Power-up or Reset Function LEDsLNK LAG M460ML-SPV Supervisor Module Ports M460ML-SPV Left and Right PushbuttonsEth Port Outband Connection RS-232 Port Sideband ConnectionM460ML-SPV ASB Alternate Software Bank Pushbutton P460 Supervisor Module ASB PushbuttonPower Supply Panel Page Maximizing Avaya P460 Availability M460ML-SPV Supervisor Module RedundancyM460ML-SPV Supervisor Module Modes Synchronizing the Supervisor Modules Manually Configuration File Synchronization Following screen capture shows the processMaximizing Avaya P460 Availability Redundant Power Supplies P460 show environment powerCalculating the Power Budget Sample Power Budget CalculationEstablishing Switch Access Establishing a Console Connection with the P460Establishing a Telnet Connection with the Switch Inband Inband Interface Connection CLI CommandsEstablishing a Telnet Connection with the Switch Outband M460ML-SPV Supervisor Module Fast Ethernet Console PortOutband Interface Connection CLI Commands Redundant Outband Connections Redundant Outband ConnectionsSideband PPP Interface CLI Commands OverviewSetting Up Sideband PPP Connection Configuration Set interface ppp ipaddrnet-maskPage Avaya Msnm P460 Manager Running the Avaya Msnm P460 Manager WelcomeP460 Device Manager Installing the Java Plug-in Installing from the P460 Documentation and Utilities CDInstall from the Avaya Web Site Install from your Local Web SiteDocumentation Page User Authentication Access LevelsLocal User Accounts Local User Account CLI Commands Radius Introduction to RadiusIllustrates the Radius authentication procedure Radius CLI CommandsUser Authentication Allowed Manager CLI Commands Allowed ManagersConfiguration Defaults Default System ParametersConfiguration Default CLI Commands Basic Switch Configuration System Parameter Configuration Identifying the systemOperating parameters Time Parameter Configuration Feature License ConfigurationFeature Activation Obtaining a License Key Click Generate Feature License CLI Commands Activating a Routing License KeyTroubleshooting the Installation Powering up the ChassisPowering up the Supervisor Modules Powering up the Fan ModulePowering up the I/O Modules Supervisor Module does not Boot Page Maintenance One Supervisor Module in the SwitchTwo Supervisor Modules in the Switch Replacing I/O ModulesFirmware Download IntroductionPreferred Bank Configuration File Management Firmware Download CLI CommandsConfiguration Management CLI Commands Page Standards IeeeRouting Specifications PhysicalPower Requirements SafetyEnvironmental EMC Emissions ImmunityTransportation Catalog Numbers Avaya P460 Catalog Numbers