Casio P460 manual M460ML-SPV ASB Alternate Software Bank Pushbutton

Page 46

Chapter 5 Avaya P460 Panels

M460ML-SPV ASB (Alternate Software Bank) Pushbutton

Figure 5.6 P460 Supervisor Module ASB Pushbutton

See “Supervisor Module does not Boot“ in “Troubleshooting the Installation“ for information.

32

Avaya P460 Installation and Maintenance Guide

Image 46
Contents Avaya P460 Page Contents Table of Contents Radius Ieee Ietf List of Tables List of Tables Avaya P460 Installation and Maintenance Guide List of Figures Page Safety Information Before you Install the Avaya P460Power Supplies FCC Notice Conventions Used in the DocumentationAvaya Support WarrantyCLI Conventions Preface Avaya P460 Installation and Maintenance Guide Avaya P460 Overview IntroductionFlexibility Avaya P460 Key FeaturesHigh Availability Management and MonitoringAvaya P460 Chassis and Module Installation Operating SafetyRequired Tools Environmental PrerequisitesAC Power Requirements Chassis Component Location KeyInstalling the P460 on a Table Top Rack Mounting140 mm P460 Rack mounting procedure Positioning the rack-mounting bracketsCable Guide Installation Installing the Cable GuidePSU Power Supply Unit Installation Fan Module Replacement or Installation Avaya P460 Switch Fan Module LocationInstalling the Avaya P460 Fan Module Supervisor Module Installation Location of the Avaya P460 Supervisor ModulesInstalling the P460 Supervisor Module Module Installation 10 Lcoation of Avaya P460 I/O ModulesModule Installation Procedure 11 I/O Module Component Location12 Installing P460 I/O Modules Installing a PSU Turning on the Avaya P460Turning on a Chassis with a Supervisor Module Only Powering UpInserting an Additional PSU Turning on a Chassis with no ModulesIf there is one PSU Removing or Switching off a PSUIf there are two PSUs If there are three PSUs Power Management Power Management ProcessI/O Module Power Management Process M460ML-SPV Panel Avaya P460 PanelsM460ML-SPV LEDs PWR ACT LED and OPR LED Summary Starting Point After Power-up or Reset Function LEDsLNK LAG Eth Port Outband Connection M460ML-SPV Supervisor Module PortsM460ML-SPV Left and Right Pushbuttons RS-232 Port Sideband ConnectionM460ML-SPV ASB Alternate Software Bank Pushbutton P460 Supervisor Module ASB PushbuttonPower Supply Panel Page M460ML-SPV Supervisor Module Redundancy Maximizing Avaya P460 AvailabilityM460ML-SPV Supervisor Module Modes Synchronizing the Supervisor Modules Manually Configuration File Synchronization Following screen capture shows the processMaximizing Avaya P460 Availability Redundant Power Supplies P460 show environment powerCalculating the Power Budget Sample Power Budget CalculationEstablishing Switch Access Establishing a Console Connection with the P460Establishing a Telnet Connection with the Switch Inband Inband Interface Connection CLI CommandsEstablishing a Telnet Connection with the Switch Outband M460ML-SPV Supervisor Module Fast Ethernet Console PortOutband Interface Connection CLI Commands Redundant Outband Connections Redundant Outband ConnectionsSideband PPP Interface CLI Commands OverviewSetting Up Sideband PPP Connection Configuration Set interface ppp ipaddrnet-maskPage Avaya Msnm P460 Manager Running the Avaya Msnm P460 Manager WelcomeP460 Device Manager Install from the Avaya Web Site Installing the Java Plug-inInstalling from the P460 Documentation and Utilities CD Install from your Local Web SiteDocumentation Page Access Levels User AuthenticationLocal User Accounts Local User Account CLI Commands Radius Introduction to RadiusIllustrates the Radius authentication procedure Radius CLI CommandsUser Authentication Allowed Manager CLI Commands Allowed ManagersConfiguration Defaults Default System ParametersConfiguration Default CLI Commands Basic Switch Configuration Identifying the system System Parameter ConfigurationOperating parameters Feature License Configuration Time Parameter ConfigurationFeature Activation Obtaining a License Key Click Generate Feature License CLI Commands Activating a Routing License KeyPowering up the Supervisor Modules Troubleshooting the InstallationPowering up the Chassis Powering up the Fan ModulePowering up the I/O Modules Supervisor Module does not Boot Page Two Supervisor Modules in the Switch MaintenanceOne Supervisor Module in the Switch Replacing I/O ModulesIntroduction Firmware DownloadPreferred Bank Firmware Download CLI Commands Configuration File ManagementConfiguration Management CLI Commands Page Standards IeeeRouting Specifications PhysicalSafety Power RequirementsEnvironmental Immunity EMC EmissionsTransportation Catalog Numbers Avaya P460 Catalog Numbers