Casio P460 manual Establishing a Telnet Connection with the Switch Outband

Page 57

Chapter 7 Establishing Switch Access

In order to...

Use the following command...

 

 

 

 

Display information on the device

show interface

network interfaces

 

 

 

Send an ICMP echo request packets

ping

to another node on the network.

 

 

 

Note: For more detailed information on the CLI commands, please refer to the Avaya P460 Reference Guide

Establishing a Telnet Connection with the Switch (Outband)

Figure 7.2 M460ML-SPV Supervisor Module Fast Ethernet Console Port

Perform the following steps to establish a Telnet connection to the P460 for configuration:

You need to assign an outband interface IP address using a direct connection to the console serial port before you can establish the Telnet session.

You can configure the Fast Ethernet console port parameters if necessary.

The outband interface should be on a different subnet from the inband interface.

1Connect your station to the Fast Ethernet console port (directly or via the network).

2Verify that you can communicate with the P460 using “ping” to the outband interface IP of the P460. If there is no response using the Ping command, check the IP address and default gateway of both the P460 and the station.

3Start a Telnet session:

From the Microsoft Windows® taskbar of your PC click Start and then Run or access the command prompt

Start the Telnet session by typing: telnet <P460_IP_address>

For example: telnet 149.49.35.214

XThe Login Name prompt is displayed

4 Enter the default name root

XThe password prompt is displayed

5 Enter the password root in lower case letters.

Avaya P460 Installation and Maintenance Guide

43

Image 57
Contents Avaya P460 Page Contents Table of Contents Radius Ieee Ietf List of Tables List of Tables Avaya P460 Installation and Maintenance Guide List of Figures Page Before you Install the Avaya P460 Safety InformationPower Supplies Conventions Used in the Documentation FCC NoticeWarranty Avaya SupportCLI Conventions Preface Avaya P460 Installation and Maintenance Guide Introduction Avaya P460 OverviewHigh Availability Avaya P460 Key FeaturesFlexibility Management and MonitoringOperating Safety Avaya P460 Chassis and Module InstallationEnvironmental Prerequisites Required ToolsAC Power Requirements Key Chassis Component LocationRack Mounting Installing the P460 on a Table Top140 mm Positioning the rack-mounting brackets P460 Rack mounting procedureInstalling the Cable Guide Cable Guide InstallationPSU Power Supply Unit Installation Avaya P460 Switch Fan Module Location Fan Module Replacement or InstallationInstalling the Avaya P460 Fan Module Location of the Avaya P460 Supervisor Modules Supervisor Module InstallationInstalling the P460 Supervisor Module 10 Lcoation of Avaya P460 I/O Modules Module Installation11 I/O Module Component Location Module Installation Procedure12 Installing P460 I/O Modules Turning on the Avaya P460 Installing a PSUInserting an Additional PSU Powering UpTurning on a Chassis with a Supervisor Module Only Turning on a Chassis with no ModulesRemoving or Switching off a PSU If there is one PSUIf there are two PSUs If there are three PSUs Power Management Process Power ManagementI/O Module Power Management Process Avaya P460 Panels M460ML-SPV PanelM460ML-SPV LEDs PWR ACT LED and OPR LED Summary Function LEDs Starting Point After Power-up or ResetLNK LAG M460ML-SPV Left and Right Pushbuttons M460ML-SPV Supervisor Module PortsEth Port Outband Connection RS-232 Port Sideband ConnectionP460 Supervisor Module ASB Pushbutton M460ML-SPV ASB Alternate Software Bank PushbuttonPower Supply Panel Page Maximizing Avaya P460 Availability M460ML-SPV Supervisor Module RedundancyM460ML-SPV Supervisor Module Modes Synchronizing the Supervisor Modules Manually Following screen capture shows the process Configuration File SynchronizationMaximizing Avaya P460 Availability P460 show environment power Redundant Power SuppliesSample Power Budget Calculation Calculating the Power BudgetEstablishing a Console Connection with the P460 Establishing Switch AccessInband Interface Connection CLI Commands Establishing a Telnet Connection with the Switch InbandM460ML-SPV Supervisor Module Fast Ethernet Console Port Establishing a Telnet Connection with the Switch OutbandOutband Interface Connection CLI Commands Redundant Outband Connections Redundant Outband ConnectionsOverview Sideband PPP Interface CLI CommandsSet interface ppp ipaddrnet-mask Setting Up Sideband PPP Connection ConfigurationPage Avaya Msnm P460 Manager Welcome Running the Avaya Msnm P460 ManagerP460 Device Manager Installing from the P460 Documentation and Utilities CD Installing the Java Plug-inInstall from the Avaya Web Site Install from your Local Web SiteDocumentation Page User Authentication Access LevelsLocal User Accounts Local User Account CLI Commands Introduction to Radius RadiusRadius CLI Commands Illustrates the Radius authentication procedureUser Authentication Allowed Managers Allowed Manager CLI CommandsDefault System Parameters Configuration DefaultsConfiguration Default CLI Commands Basic Switch Configuration System Parameter Configuration Identifying the systemOperating parameters Time Parameter Configuration Feature License ConfigurationFeature Activation Obtaining a License Key Click Generate Activating a Routing License Key Feature License CLI CommandsPowering up the Chassis Troubleshooting the InstallationPowering up the Supervisor Modules Powering up the Fan ModulePowering up the I/O Modules Supervisor Module does not Boot Page One Supervisor Module in the Switch MaintenanceTwo Supervisor Modules in the Switch Replacing I/O ModulesFirmware Download IntroductionPreferred Bank Configuration File Management Firmware Download CLI CommandsConfiguration Management CLI Commands Page Ieee StandardsRouting Physical SpecificationsPower Requirements SafetyEnvironmental EMC Emissions ImmunityTransportation Avaya P460 Catalog Numbers Catalog Numbers