Honeywell W7761A specifications Cabling

Page 35

EXCEL 10 W7761A INPUT/OUTPUT DEVICE

Table 8. Excel 10 W7761A Device Ordering Information (Continued).

Part Number

Product Description

Comments

 

 

 

 

Accessories (Continued):

 

ML6474A1008

Direct Coupled Actuator, 132 lb-in. torque, Series 60

 

 

 

ML6185A1000

Direct Coupled Actuator, 50 lb-in. spring return

Series 60

 

 

 

EL7680A1008

Wall Mounted Wide View Infrared Occupancy Sensor

 

 

 

EL7628A1007

Ceiling Mounted Infrared Occupancy Sensor

 

 

 

EL7611A1003,

Ultrasonic Occupancy Sensors

 

EL7612A1001

 

 

 

 

EL7630A1003,

Power Supply/Control Units for Occupancy sensors

 

EL7621A1002,

 

EL7621A1010

 

 

 

 

 

C7400A1004

Solid State Enthalpy Sensor (4 to 20 mA)

For outdoor and return air enthalpy

 

 

 

C7600B1000

Solid State Humidity Sensor (2 to 10 V)

For outdoor and return air humidity

 

 

 

C7600C1008

Solid State Humidity Sensor (4 to 20 mA)

For outdoor and return air humidity

 

 

 

C7600C1018

Solid State Humidity Sensor (2 to 10 V)

For outdoor and return air humidity

 

 

 

MMC325-010,

Pneumatic Retrofit Transducers.

Use to control Pneumatic reheat valves

MMC325-020

Select pressure range: (010) 0 to 10 psi (68.97 kPa)

 

 

or (020) 0 to 20 psi (137.93 kPa).

 

 

 

 

MMCA530

DIN rail adapter for MMC325 Transducers

 

 

 

MMCA540

Metal enclosure for MMC325 Transducers

 

 

 

ML7984B3000

Valve Actuator Pulse Width Modulation (PWM)

Use with V5011 or V5013 F and G Valves

 

 

 

ML6161B1000

Damper Actuator Series 60

 

 

 

M6410A

Valve Actuator Series 60

Use with V5812/V5813 Valves

 

 

 

ML684A1025

Versadrive Valve Actuator with linkage, Series 60

Use with V5011 and V5013 Valves

 

 

 

ML6464A1009

Direct Coupled Actuator, 66 lb-in., Series 60

 

 

 

ML6474A1008

Direct Coupled Actuator, 132 lb-in. torque, Series 60

 

 

 

ML6185A1000

Direct Coupled Actuator, 50 lb-in. spring return

Series 60

 

 

 

V5812A

Two-way terminal unit water valve; 0.19, 0.29, 0.47,

Use with M6410 Valve Actuator. Close-off

 

0.74, 1.2, and 1.9 Cv 1/2 in. npt (13 mm) or

rating for 0.19 to 1.9 Cv is 65 psi; for 2.9

 

2.9 and 4.9 Cv 3/4 in. npt (19 mm)

and 4.9, Cv is 45 psi. (Coefficient of

 

 

volume or capacity index Cv = gallons per

 

 

minute divided by the square root of the

 

 

pressure drop across the valve.)

 

 

 

V5813A

Three-way mixing terminal unit hot water valve; 0.19,

Use with M6410 Valve Actuator. Close-off

 

0.29, 0.47, 0.74, 1.2, and 1.9 Cv 1/2 in. npt (13 mm)

rating 0.19 to 0.74 Cv is 55 psi; 1.2, and

 

or 2.9 and 4.9 Cv 3/4 in. npt (19 mm)

1.9 Cv is 22 psi; 2.9 and 4.9 Cv is 26 psi.

R8242A

Contactor, 24 Vac coil, DPDT

 

 

 

AT72D, AT88A, AK3310, etc.

Transformers

 

 

 

EN 50 022

DIN rail 35 mm by 7.5 mm (1-3/8 in. by 5/16 in.)

Obtain locally: A controller requires 5 in.

 

 

 

Augat Inc. part number 2TK2D DIN rail (adapter)

Purchase from Augat Inc. two DIN rail

 

 

adapters for each controller

 

 

 

Serial Interface Cable, male DB-9 to female DB-9 or

Obtain locally from any computer

 

female DB-25.

hardware vendor.

 

 

 

Cabling

Honeywell AK3791 (one

E-Bus (plenum): 22 AWG (0.34 mm2) twisted pair

Level IV 140°F (60°C) rating

twisted pair) AK3792 (two

solid conductor, nonshielded or Echelon® approved

 

twisted pairs)

cable.

 

 

 

 

Honeywell AK3781 (one

E-Bus (nonplenum): 22 AWG (0.34 mm2) twisted pair

Level IV 140°F (60°C) rating

twisted pair) AK3782 (two

solid conductor, nonshielded or Echelon® approved

 

twisted pairs)

cable.

 

 

 

 

Honeywell AK3725

Inputs: 18 AWG (1.0 mm2) five wire cable bundle

Standard thermostat wire

(continued)

35

74-2699

Image 35
Contents Excel 10 W7761A Remote Input/Output Device Appendices List of TablesTypical system overview Description of DevicesOrganization of Manual Control ApplicationControl Provided Products CoveredProduct Names Abbreviations and Definitions Agency ListingsExcel 10 W7761A INPUT/OUTPUT Device Controllers ConstructionExcel 10 W7761A Remote I/O Device W7761A construction in in. mm List Of Available Points W7761A Performance Specifications PowerMemory Capacity Specified Space Temperature Sensing RangeEnvironmental Operating Temperature Shipping TemperatureMixed Air Temperature Discharge Air TemperatureOutdoor Air Temperature Return Air Temperature5585 Wall ModulesT7780 construction, subbase dimensions in in. mm ConfigurationsWall Module Options Mixed-Output-Type ControlOccupancy Sensor Window Open/Closed Digital InputApplication Steps Step No Description OverviewPlan The System Bus Layout Lay Out Communications and Power WiringDetermine Other Bus Devices Required 750,1$ Power Budget Calculation Example Power WiringLine Loss VA Ratings For Transformer Sizing Device DescriptionNema class 2 transformer voltage output limits VA RatingLine VOLTAGE` GREATER` Than 150 VAC W7761A Devices Prepare Wiring DiagramsGeneral Considerations Terminal Number Description W7761A I/O DescriptionTemperature Sensor DE V IC E Window Contact Contact Closed = Occupancy Sensor Occupied Valve Actuator Typical Pneumatic transducer Series 60 Floating to W7761A Bus Termination ModuleSee for E-Bus termination wiring options +$672 Sensors Order EquipmentExcel 10 W7750 Controllers T7770 Wall ModulesEchelon Based Components and Parts AccessoriesCabling Temperature Degrees W7761A Device Status LED Broadcasting the Service MessageExcel 10 Alarms LED States T7780 Ddwm Bypass PushbuttonAdding Analog Inputs Enthalpy 4 to 20 mA Appendix A. Using E-Vision to Commission a W7761 DeviceAdding Other VOLTAGE/CURRENT Sensors Adding Digital Inputs Common Operations Room Temperature Sensor RmTempAppendix B. Sequences of Operation Pulse Width Modulating PWM Control Window Sensor StatusWndwDirty Filter Monitor Series 60 Modulating ControlCO 2 Concentration Temperature Relative HumidityRelative Air FlowTable C1. Input/Output Points Left DefaultTable C1. Input/Output Points Right Excel 10 W7761A INPUT/OUTPUT Device Values that can be assigned to any output channels English Metric or User Address DI3Sel1Type Refer to the description for DI1Sel1Type Stoff Stnul Stlow Stmed Sthigh Ston DO2Type Excel 10 W7761A INPUT/OUTPUT Device SrcDigIn2Sts Refer to the description for SrcDigIn1Sts Table C2. Control Parameters Left SH MA DA EV HW MN TS Table C2. Control Parameters RightTable C3. Status Points Left NoalarmTable C3. Status Points Right RIO1 Software version NvoStatus InOverride SH MA DA EV HW MN TS Table C4. Configuration Parameters Left Table C4. Configuration Parameters Right DO0 Higher than the value specified for AILowLimit DO4 Seconds = 25.6 seconds DO6PWMPeriod Refer to the description for DO1PWMPeriod Table C5. Direct Access And Special Points Right Table C5. Direct Access And Special Points LeftFig. D-1. Point capacity estimate for Zone Manager Approximate Memory Size Estimating ProcedureSensor Use Appendix E. Sensor Data for CalibrationResistance Sensors Sensor Type1956.79 Humidity Percentage Sensor Voltage Voltage/Current SensorsTable E-4. Sensor Voltage Versus Humidity C7600C1008 4 to 20 mA C7600C output current vs. humidity Sensor Type Fig. E-6. Graph of Sensor Current versus Enthalpy volts Table E-10. Sensor Voltage Versus Input Voltage To A/D Table E-9. Sensor Voltage Versus CO 2 ConcentrationCO 2 Concentration PPM Sensor Voltage Pressure Inw kPa Sensor Voltage Vdc Voltage to A/D Sensor VoltageTable E-11. Sensor Voltage Vdc Versus Pressure Inw 3ODD