EXCEL 10 W7761A INPUT/OUTPUT DEVICE
Table 8. Excel 10 W7761A Device Ordering Information (Continued).
Part Number | Product Description | Comments |
|
|
|
| Accessories (Continued): |
|
ML6474A1008 | Direct Coupled Actuator, 132 | — |
|
|
|
ML6185A1000 | Direct Coupled Actuator, 50 | Series 60 |
|
|
|
EL7680A1008 | Wall Mounted Wide View Infrared Occupancy Sensor | — |
|
|
|
EL7628A1007 | Ceiling Mounted Infrared Occupancy Sensor | — |
|
|
|
EL7611A1003, | Ultrasonic Occupancy Sensors |
|
EL7612A1001 |
| — |
|
|
|
EL7630A1003, | Power Supply/Control Units for Occupancy sensors |
|
EL7621A1002, |
| — |
EL7621A1010 |
|
|
|
|
|
C7400A1004 | Solid State Enthalpy Sensor (4 to 20 mA) | For outdoor and return air enthalpy |
|
|
|
C7600B1000 | Solid State Humidity Sensor (2 to 10 V) | For outdoor and return air humidity |
|
|
|
C7600C1008 | Solid State Humidity Sensor (4 to 20 mA) | For outdoor and return air humidity |
|
|
|
C7600C1018 | Solid State Humidity Sensor (2 to 10 V) | For outdoor and return air humidity |
|
|
|
Pneumatic Retrofit Transducers. | Use to control Pneumatic reheat valves | |
Select pressure range: (010) 0 to 10 psi (68.97 kPa) |
| |
| or (020) 0 to 20 psi (137.93 kPa). |
|
|
|
|
MMCA530 | DIN rail adapter for MMC325 Transducers | — |
|
|
|
MMCA540 | Metal enclosure for MMC325 Transducers | — |
|
|
|
ML7984B3000 | Valve Actuator Pulse Width Modulation (PWM) | Use with V5011 or V5013 F and G Valves |
|
|
|
ML6161B1000 | Damper Actuator Series 60 | — |
|
|
|
M6410A | Valve Actuator Series 60 | Use with V5812/V5813 Valves |
|
|
|
ML684A1025 | Versadrive Valve Actuator with linkage, Series 60 | Use with V5011 and V5013 Valves |
|
|
|
ML6464A1009 | Direct Coupled Actuator, 66 | — |
|
|
|
ML6474A1008 | Direct Coupled Actuator, 132 | — |
|
|
|
ML6185A1000 | Direct Coupled Actuator, 50 | Series 60 |
|
|
|
V5812A | Use with M6410 Valve Actuator. | |
| 0.74, 1.2, and 1.9 Cv 1/2 in. npt (13 mm) or | rating for 0.19 to 1.9 Cv is 65 psi; for 2.9 |
| 2.9 and 4.9 Cv 3/4 in. npt (19 mm) | and 4.9, Cv is 45 psi. (Coefficient of |
|
| volume or capacity index Cv = gallons per |
|
| minute divided by the square root of the |
|
| pressure drop across the valve.) |
|
|
|
V5813A | Use with M6410 Valve Actuator. | |
| 0.29, 0.47, 0.74, 1.2, and 1.9 Cv 1/2 in. npt (13 mm) | rating 0.19 to 0.74 Cv is 55 psi; 1.2, and |
| or 2.9 and 4.9 Cv 3/4 in. npt (19 mm) | 1.9 Cv is 22 psi; 2.9 and 4.9 Cv is 26 psi. |
R8242A | Contactor, 24 Vac coil, DPDT | — |
|
|
|
AT72D, AT88A, AK3310, etc. | Transformers | — |
|
|
|
EN 50 022 | DIN rail 35 mm by 7.5 mm | Obtain locally: A controller requires 5 in. |
|
|
|
— | Augat Inc. part number 2TK2D DIN rail (adapter) | Purchase from Augat Inc. two DIN rail |
|
| adapters for each controller |
|
|
|
— | Serial Interface Cable, male | Obtain locally from any computer |
| female | hardware vendor. |
|
|
|
Cabling
Honeywell AK3791 (one | Level IV 140°F (60°C) rating | |
twisted pair) AK3792 (two | solid conductor, nonshielded or Echelon® approved |
|
twisted pairs) | cable. |
|
|
|
|
Honeywell AK3781 (one | Level IV 140°F (60°C) rating | |
twisted pair) AK3782 (two | solid conductor, nonshielded or Echelon® approved |
|
twisted pairs) | cable. |
|
|
|
|
Honeywell AK3725 | Inputs: 18 AWG (1.0 mm2) five wire cable bundle | Standard thermostat wire |
(continued)
35 |