Honeywell W7761A specifications DO2Type

Page 52

EXCEL 10 W7761A INPUT/OUTPUT DEVICE

Table C1. Input/Output Points (Right Continued).

Share (SH), Map (MA), Direct Access (DA)

E-Vision (EV): Calibrate (C), Monitor (M),

Parameter (P), Schematic (S)

Hardware Configuration (HW),

Manual Point (MN), Test (TS)

SH

MA

DA

EV

HW

MN

TS

Comments

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

DO2Type:

 

 

 

 

 

 

 

Refer to the description for DO1Type.

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

DO3Type:

 

 

 

 

 

 

 

Refer to the description for DO1Type.

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

DO4Type:

 

 

 

 

 

 

 

Refer to the description for DO1Type.

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

DO5Type:

 

 

 

 

 

 

 

Refer to the description for DO1Type.

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

DO6Type:

 

 

 

 

 

 

 

Refer to the description for DO1Type.

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

DO7Type:

 

 

 

 

 

 

 

Refer to the description for DO1Type.

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

DO8Type:

 

 

 

 

 

 

 

Refer to the description for DO1Type.

 

 

 

 

 

 

 

 

 

 

X

 

X

 

 

FiftySixtyHz specifies the power supply frequency. Correctly selecting FiftySixtyHz

 

 

 

 

 

 

 

decreases the noise picked up by analog sensor wiring from the power supply.

 

 

 

 

 

 

 

When FiftySixtyHz is 1, the power supply frequency is Fifty Hz and when

 

 

 

 

 

 

 

FiftySixtyHz is 0, the power supply frequency is Sixty Hz.

 

 

 

 

 

 

 

 

X

X

X

M

 

 

 

SrcCO2Level is an output network variable corresponding to the voltage or current

 

 

 

 

 

 

 

input channel (AI5 or AI6) if the selection for a CO2 sensor was made via

 

 

 

 

 

 

 

ncirioIoSelect.

 

 

 

 

 

 

 

 

X

X

X

M

 

 

 

SrcCurrentAI is an output network variable corresponding to the voltage or current

 

 

 

 

 

 

 

input channel (AI5 or AI6) if the selection for a current sensor was made via

 

 

 

 

 

 

 

ncirioIoSelect.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SrcDigIn1Sts: There are four digital input channels (DI1 through DI4). If any of the

 

 

 

 

 

 

 

four channels are configured, the corresponding output network variable will be

 

 

 

 

 

 

 

updated with the value whose data type is SNVT_switch.

 

 

 

 

 

 

 

 

X

X

X

M

 

 

 

DI1State: There are four digital input channels (DI1 through DI4). If any of the four

 

 

 

 

 

 

 

channels are configured, the corresponding output network variable will be updated

 

 

 

 

 

 

 

with the value whose data type is SNVT_switch. Refer to the enumerated list that is

 

 

 

 

 

 

 

shown in the Eng. Units/States column.

 

 

 

 

 

 

 

 

(continued)

52

74-2699

Image 52
Contents Excel 10 W7761A Remote Input/Output Device List of Tables AppendicesDescription of Devices Typical system overviewControl Application Control ProvidedProducts Covered Organization of ManualProduct Names Agency Listings Abbreviations and DefinitionsExcel 10 W7761A INPUT/OUTPUT Device Construction ControllersExcel 10 W7761A Remote I/O Device W7761A construction in in. mm Performance Specifications Power List Of Available Points W7761ASpecified Space Temperature Sensing Range Environmental Operating TemperatureShipping Temperature Memory CapacityDischarge Air Temperature Outdoor Air TemperatureReturn Air Temperature Mixed Air TemperatureWall Modules 5585Configurations T7780 construction, subbase dimensions in in. mmMixed-Output-Type Control Occupancy SensorWindow Open/Closed Digital Input Wall Module OptionsPlan The System OverviewApplication Steps Step No Description Determine Other Bus Devices Required Lay Out Communications and Power WiringBus Layout 750,1$ Power Wiring Power Budget Calculation ExampleVA Ratings For Transformer Sizing Device Description Line LossVA Rating Nema class 2 transformer voltage output limitsLine VOLTAGE` GREATER` Than 150 VAC General Considerations Prepare Wiring DiagramsW7761A Devices W7761A I/O Description Terminal Number DescriptionTemperature Sensor DE V IC E Window Contact Contact Closed = Occupancy Sensor Occupied Valve Actuator Bus Termination Module Typical Pneumatic transducer Series 60 Floating to W7761ASee for E-Bus termination wiring options +$672 Order Equipment Excel 10 W7750 ControllersT7770 Wall Modules SensorsAccessories Echelon Based Components and PartsCabling Temperature Degrees Excel 10 Alarms Broadcasting the Service MessageW7761A Device Status LED T7780 Ddwm Bypass Pushbutton LED StatesAppendix A. Using E-Vision to Commission a W7761 Device Adding Analog Inputs Enthalpy 4 to 20 mAAdding Other VOLTAGE/CURRENT Sensors Adding Digital Inputs Appendix B. Sequences of Operation Room Temperature Sensor RmTempCommon Operations Window Sensor StatusWndw Dirty Filter MonitorSeries 60 Modulating Control Pulse Width Modulating PWM ControlTemperature Relative Humidity RelativeAir Flow CO 2 ConcentrationDefault Table C1. Input/Output Points LeftTable C1. Input/Output Points Right Excel 10 W7761A INPUT/OUTPUT Device Values that can be assigned to any output channels English Metric or User Address DI3Sel1Type Refer to the description for DI1Sel1Type Stoff Stnul Stlow Stmed Sthigh Ston DO2Type Excel 10 W7761A INPUT/OUTPUT Device SrcDigIn2Sts Refer to the description for SrcDigIn1Sts Table C2. Control Parameters Left Table C2. Control Parameters Right SH MA DA EV HW MN TSNoalarm Table C3. Status Points LeftTable C3. Status Points Right RIO1 Software version NvoStatus InOverride SH MA DA EV HW MN TS Table C4. Configuration Parameters Left Table C4. Configuration Parameters Right DO0 Higher than the value specified for AILowLimit DO4 Seconds = 25.6 seconds DO6PWMPeriod Refer to the description for DO1PWMPeriod Table C5. Direct Access And Special Points Left Table C5. Direct Access And Special Points RightApproximate Memory Size Estimating Procedure Fig. D-1. Point capacity estimate for Zone ManagerAppendix E. Sensor Data for Calibration Resistance SensorsSensor Type Sensor Use1956.79 Table E-4. Sensor Voltage Versus Humidity Voltage/Current SensorsHumidity Percentage Sensor Voltage C7600C1008 4 to 20 mA C7600C output current vs. humidity Sensor Type Fig. E-6. Graph of Sensor Current versus Enthalpy volts CO 2 Concentration PPM Sensor Voltage Table E-9. Sensor Voltage Versus CO 2 ConcentrationTable E-10. Sensor Voltage Versus Input Voltage To A/D Table E-11. Sensor Voltage Vdc Versus Pressure Inw Voltage to A/D Sensor VoltagePressure Inw kPa Sensor Voltage Vdc 3ODD