Controlling

Analog Picture Controls

The analog picture controls can be adjusted with the RCU. The control keys are located on the lower right side of the key panel of the RCU and indicated with the name of the control and an icon.

When an analog picture control is pressed, a text box with bar scale and the function name of the control, e.g. ‘brightness...’ appears on the screen (only if ‘TEXT’ is ON). The length of the bar scale indicates the current memorized setting for this source. The bar scale changes as the + or - buttons of the control are pressed.

Tint Control

Tint is only active for Video and S-Video. Tint control is effective only when using the NTSC 4.43 or NTSC 3.58 system. A bar scale gives a visual indication on the screen of the current tint setting while pressing the + or - buttons (RCU) or pushing the control disk to the left or to the right (local keypad). If the bar scale is not visi- ble on the screen, press the ‘TEXT’ key once and retry the above indicated buttons.

The bar scale increases when pressing on the + button and decreases when pressing the - button.

BRIGHTNESS

40

Brightness Control

A correct ‘brightness’ setting is important for good image repro- duction. Adjust the brightness with the + or - button (RCU) until the darkest parts of the picture appear black.

A bar scale gives a visual indication on the screen of the current brightness setting while pressing on the above indicated keys. If the bar scale is not visible on the screen, press ‘TEXT’ key once and retry the above indicated keys.

The bar scale increases when pressing on the + button (higher brightness) and decreases when pressing on the - button (lower brightness).

Contrast Control

A correct ‘contrast’ setting is important for good image reproduc- tion. Adjust the contrast to the level you prefer, according to room lighting conditions. If the Contrast Control is too low, the picture will be too dim. If it is set too high, the picture may be too bright and not sharp. A bar scale gives a visual indication on the screen of the current contrast setting while pressing the + or - buttons (RCU). If the bar scale is not visible on the screen, press ‘TEXT’ key once and retry the above indicated keys.

The bar scale increases when pressing on the + button (higher contrast) and decreases when pressing on the - button (lower con- trast).

Color Saturation Control

Color saturation is only active for Video and S-Video. Adjust the color intensity of the picture. Adjust the color saturation using the

=and - buttons (RCU) or pushing the control disk to the left or to the right (local keypad). A bar scale gives a visual indication on the screen of the current color setting while pressing on the above indi- cated buttons. If the bar scale is not visible on the screen, press ‘TEXT’ key once and retry the above indicated buttons. The bar scale increases when pressing on the + button (richer colors) and decreases when pressing the - button (lighter colors).

Sharpness Control

Sharpness control is only active for Video and S-Video. A bar scale gives a visual indication on the screen of the current sharpness setting while pressing the + or - buttons (RCU) or pushing the con- trol disk to the left or to the right (local keypad). If the bar scale is not visible on the screen, press ‘TEXT’ key once and retry the above indicated buttons.

The bar scale increases when pressing on the + button (sharper picture) and decreases when pressing on the - button (softer pic- ture).

The Pause key

When the Pause key is pressed, the image projection is muted but the projector remains with full power for immediate restart.

To restart the image :

-Press the Pause key,

-Select a source number.

GENERAL ACCESS

SHARPNESS

TINT

COLOR

BRIGHTNESS

CONTRAST

Quit ADJUST

Select with or

then <ENTER> <EXIT> to return

The GENERAL ACCESS MENU is available from the LOCAL KEYPAD.

Press the ADJ 3X to display.

4-4

Image 20
Contents DTV-992/992 Ultra Page Table of Contents Table of Contents APX-6 APP-3EYE-QTMDIAGNOSTICS Safety Instructions Installation InstructionsSafety Instructions Front Panel Terminology Location and Function of ControlsRear Panel Terminology RCU control panel terminology Control panel terminologyLocal Keypad IR Transmission Indicator AC Power mains Cord Connection Power CheckSwitching On/Off ConnectionsPort No Projector Input Press Digit Button Signal Input Connection to the ProjectorStart up with full white image Connecting a RGB Analog source with composite sync Connecting a RGB Analog source with Tri-level syncRgbs or RGsB input selection RGB3S or RG3sB input selectionYYB-YS or R-YYsB-Y input selection Connecting a Component sourceConnecting a Component source with Tri-level sync Data communications Remote controlYYB-Y3S or R-YY3sB-Y input selection Battery installation in the RCU ControllingHow to use your RCU Using your RCUHow to display a projector address? Hardware set up of the projector addressGeneral Access Menu Items Source Input selectionAnalog Picture Controls Pause keyStart UP of the Adjustment Mode Adjustment modeStart Up of the Adjustment Mode Overview ‘Random Access Adjustment’ mode Random Access Adjustment ModeStarting up the random access adjustment mode Selecting Setup Pattern Internal Cross Hatch PatternRandom access adjustment mode selection menu Picture TuningSync Fast/Slow Adjustment Color BalancePeaking Color SelectPress Enter to display the color select menu Display the projected image in that specific colorFocusing FocusingGeometry Adjustments Horizontal Phase AdjustmentPhase GeometryRaster Shift Adjustment Left-Right east-west Adjustments Left Right E-WLeft Side Correction Left Side Correction Left Keystone Left BOWTop-Bottom north-south Adjustments TOP Bottom N-SLinearity Size AdjustmentVertical Linearity Adjustment Blanking Adjustments Blanking TOP Bottom Left RightConvergence Convergence AdjustmentCoarse Convergence Adjustments Fine Convergence Adjustments Vertical cornersOverview flowchart ‘Service’ mode Service ModeStarting up the Service mode Identification Copy a blockIdentification Copy a BlockDeletion of blocks Deleting block by blockDelete a Block Delete ALL BlocksTotal Run Time Change passwordChange Language All settings to midposition Undo all settings to midposConvergence mid Undo R & B convergence midDynamic Astigmatism spot shape adjustment Arrow key Axial Astigmatism correctionG2 Adjustment Common Settings 12C DiagnosticsCRT run in cycle CRT RUN in Cycle Projector Warm UPProjector warm up Projector Warm UPMESSAGES, WARNINGS, and Failures SourceFailure DTV-992 DTV-992 UltraAppendix RS 232 ControlSending a Record single instruction Decimal values STXSharpness $02,$00,$00,$51,$0A,$00,$00,$00,$01,$5CQuick Guide to using the EYE-QTMsystem OverviewEasy-to-use, high precision automatic convergence system Easy-to-use, high precision automatic geometry systemCompact, built-in system Preparing your EYE-QTMAccess to EYE-QTMON-SCREEN Menus EYE-QTMMENUEYE-QTMSETUP Setting the ConfigurationFocusing the Camera Lens Centering the Camera Centering the Camera HorizontallyCentering the Camera Vertically TOUCH-UP on Source ON/OFFReference Source TOUCH-UP on TimerAdjusting Other Sources What is Being Measured by EYE-QTM Learning a ReferenceAdjusting Screen Size On Current SourceAlign from Midposition on Current Source TOUCH-UPAlign on Current Source Align on ALL Sources On ALL SourcesTOUCH-UP on ALL Sources Interrupting the Automatic Convergence Process Error MessagesAlign from Midposition on ALL Sources Status Forced break No Pattern ErrorStatus Reporting Forced Break EYE-QTMDIAGNOSTICS APX-16 Page RUMA-003700 rev