Runco runco super hdtv dtv video projector, dtv-992/992 ultra TOUCH-UP on Timer, Reference Source

Page 59

Appendix 2

TOUCH-UP ON TIMER

This option allows the static convergence to be carried out auto- matically after a user-defined time, which can be programmed in hours and/or minutes.

To program the touch-up on Timer:

Push up or down keys of the control disc to highlight ON TIMER: off;

Press the <ENTER> button to switch it to ON and the pre- set time will be displayed;

Press the <TEXT> button to enter the TOUCH-UP TIMER menu;

Push left or right keys of the control disc to highlight the digit to be changed;

Use the numeric keys to enter a desire value;

Press the <ENTER> button to confirm and the EYE-QTMSETUP menu will return on the screen; or press the <EXIT> button to leave the preset value untouched and return to the EYE-QTMSETUP menu.

Press the <EXIT> button to return to the EYE-QTMmenu.

When one adjust geometry by hand, a reference screen and a reference pattern are required. There are a lot of possibilities for a reference screen. A test pattern for a video test disc is nor- mally used. See geometry section of manual for more informa- tion. Once a selection of a reference screen and a reference pat- tern is made, adjusting geometry is only a matter of converging these two elements.

EYE-QTMrequires a reference for adjusting geometry. The sim- plest way to have a reference screen is to adjust one source by hand, which then serves as a reference for all other sources. After adjusting a source, the reference is learned by EYE-QTMand stored in non-volatile memory. Having this Reference Source in memory EYE-QTMcan adjust all other sources to have the same geometry as the Reference Source.

REFERENCE SOURCE

Before any geometric adjustment can be done, the user Must learn a Reference Source. This process is ONLY DONE ONCE since the Reference will be stored in non-volatile memory. If however, the projector is moved from its position, then the Learn Reference procedure must be repeated. After learning a Refer- ence do not touch the camera (for focusing and centering).

If using multi-aspect ratios, a Reference Geometry must be done for each aspect ratio.

ADJUSTING OTHER SOURCES

Once a Reference Source is in memory, other sources are aligned with the same geometry as the Reference Source. If no Reference Source is learned, the resulting geometry will be unpredictable.

APX-8

EYE-Q

TOUCH UP

AUTOCONVERGENCE

QUICK AUTOPICTURE

FULL AUTOPICTURE

EYE-Q SETUP

EYE-Q DIAGNOSTICS

 

EYE-Q SETUP

 

 

FOCUS THE LENS

 

 

CENTER THE CAMERA

 

CONFIGURATION: rear/front

 

 

LEARN REFERENCE

 

 

TOUCH-UP OPTIONS:

 

 

TOUCH-UP OPTIONS

 

ON SOURCE SWITCH : on/off

 

ON TIMER : on/off

 

-h.- min.

 

 

with

or

 

<ENTER>.

 

to return

EYE-Q SETUP

 

FOCUS THE LENS

 

CENTER THE CAMERA

 

CONFIGURATION: rear/front

 

LEARN REFERENCE

 

TOUCH-UP OPTIONS:

 

Select with

or

 

then <ENTER>.

 

<EXIT> to return

 

Image 59
Contents DTV-992/992 Ultra Page Table of Contents Table of Contents APP-3 APX-6EYE-QTMDIAGNOSTICS Installation Instructions Safety InstructionsSafety Instructions Front Panel Terminology Location and Function of ControlsRear Panel Terminology RCU control panel terminology Control panel terminologyLocal Keypad IR Transmission Indicator Connections AC Power mains Cord ConnectionPower Check Switching On/OffPort No Projector Input Press Digit Button Signal Input Connection to the ProjectorStart up with full white image RGB3S or RG3sB input selection Connecting a RGB Analog source with composite syncConnecting a RGB Analog source with Tri-level sync Rgbs or RGsB input selectionYYB-YS or R-YYsB-Y input selection Connecting a Component sourceConnecting a Component source with Tri-level sync Data communications Remote controlYYB-Y3S or R-YY3sB-Y input selection Controlling Battery installation in the RCUHardware set up of the projector address How to use your RCUUsing your RCU How to display a projector address?Input selection General Access Menu Items SourcePause key Analog Picture ControlsAdjustment mode Start UP of the Adjustment ModeStart Up of the Adjustment Mode Overview ‘Random Access Adjustment’ mode Random Access Adjustment ModeStarting up the random access adjustment mode Internal Cross Hatch Pattern Selecting Setup PatternColor Balance Random access adjustment mode selection menuPicture Tuning Sync Fast/Slow AdjustmentDisplay the projected image in that specific color PeakingColor Select Press Enter to display the color select menuFocusing FocusingGeometry Geometry AdjustmentsHorizontal Phase Adjustment PhaseRaster Shift Adjustment Left Right E-W Left-Right east-west AdjustmentsLeft Side Correction Left Keystone Left BOW Left Side CorrectionTOP Bottom N-S Top-Bottom north-south AdjustmentsLinearity Size AdjustmentVertical Linearity Adjustment Blanking TOP Bottom Left Right Blanking AdjustmentsConvergence Convergence AdjustmentCoarse Convergence Adjustments Vertical corners Fine Convergence AdjustmentsOverview flowchart ‘Service’ mode Service ModeStarting up the Service mode Copy a Block IdentificationCopy a block IdentificationDelete ALL Blocks Deletion of blocksDeleting block by block Delete a BlockTotal Run Time Change passwordChange Language Undo R & B convergence mid All settings to midpositionUndo all settings to midpos Convergence midArrow key Axial Astigmatism correction Dynamic Astigmatism spot shape adjustmentCRT RUN in Cycle Projector Warm UP G2 AdjustmentCommon Settings 12C Diagnostics CRT run in cycleProjector Warm UP Projector warm upSource MESSAGES, WARNINGS, and FailuresFailure DTV-992 Ultra DTV-992RS 232 Control AppendixSending a Record single instruction STX Decimal values$02,$00,$00,$51,$0A,$00,$00,$00,$01,$5C SharpnessOverview Quick Guide to using the EYE-QTMsystemPreparing your EYE-QTM Easy-to-use, high precision automatic convergence systemEasy-to-use, high precision automatic geometry system Compact, built-in systemEYE-QTMMENU Access to EYE-QTMON-SCREEN MenusSetting the Configuration EYE-QTMSETUPFocusing the Camera Lens Centering the Camera Horizontally Centering the CameraTOUCH-UP on Source ON/OFF Centering the Camera VerticallyReference Source TOUCH-UP on TimerAdjusting Other Sources Learning a Reference What is Being Measured by EYE-QTMOn Current Source Adjusting Screen SizeAlign from Midposition on Current Source TOUCH-UPAlign on Current Source Align on ALL Sources On ALL SourcesTOUCH-UP on ALL Sources Interrupting the Automatic Convergence Process Error MessagesAlign from Midposition on ALL Sources Status Forced break No Pattern ErrorStatus Reporting Forced Break EYE-QTMDIAGNOSTICS APX-16 Page RUMA-003700 rev