Runco runco super hdtv dtv video projector manual Deletion of blocks, Deleting block by block

Page 39

Service Mode

Deletion of blocks

This item is password protected.

The delete function is used to clear all data (settings) from an adjustment block.

A delete can be given :

- block by block

or

- for all blocks.

Deleting block by block

The ‘delete a block’ function deletes the settings of a selected block.

ENTER will select the pointed item.

EXIT returns to the Path Selection main menu.

ADJUST returns to the Operational mode.

Highlight ‘Delete a block’ with the control disc and press ENTER.

Push the control disc up or down to select the desired adjustment block.

ENTER displays the confirmation menu.

EXIT returns to the Service Mode main menu.

Press ENTER to delete the selected adjustment block. A confirmation menu will be displayed.

ENTER will delete the selected block.

EXIT cancels the deletion procedure and returns to the Service mode main menu.

MEMORY MANAGEMENT

COPY A BLOCK

DELETE A BLOCK

DELETE ALL BLOCKS

ALL SETTINGS TO MIDPOS

R & B CONVERGENCE MID

GR CONVERGENCE MID

 

 

DELETE MODE

 

Nr.

Src

Fh

Fv

inp conf

 

1

1

15.6

50

video

FC

2

3

31.2

60

RGB3S

RT

3

-

15.6

50

intern

FC

4

2

31.5

50

RGB3S

FC

5

-

33.7

60

intern

FC

6

 

 

 

 

 

 

 

 

DELETE BLOCK

The selected block will be deleted !

<ENTER> to confirm <EXIT> to cancel

ENTER gives a confirmation message before deleting. EXIT returns to the Path Selection main menu.

Deletion of all blocks

Highlight ‘delete all blocks’ with the control disc and press ENTER.

If you are certain you wish to delete all blocks, press ENTER to confirm, otherwise press EXIT to return.

Once ENTER is pressed, all block headers and adjustment settings are permanently removed and cannot be restored.

MEMORY MANAGEMENT

COPY A BLOCK

DELETE A BLOCK

DELETE ALL BLOCKS

ALL SETTINGS TO MIDPOS

DELETE ALL BLOCK

All block

will be deleted !

<ENTER> to confirm <EXIT> to cancel

7-3

Image 39
Contents DTV-992/992 Ultra Page Table of Contents Table of Contents APP-3 APX-6EYE-QTMDIAGNOSTICS Installation Instructions Safety InstructionsSafety Instructions Location and Function of Controls Rear Panel TerminologyFront Panel Terminology Control panel terminology Local KeypadRCU control panel terminology IR Transmission Indicator Connections AC Power mains Cord ConnectionPower Check Switching On/OffSignal Input Connection to the Projector Start up with full white imagePort No Projector Input Press Digit Button RGB3S or RG3sB input selection Connecting a RGB Analog source with composite syncConnecting a RGB Analog source with Tri-level sync Rgbs or RGsB input selectionConnecting a Component source Connecting a Component source with Tri-level syncYYB-YS or R-YYsB-Y input selection Remote control YYB-Y3S or R-YY3sB-Y input selectionData communications Controlling Battery installation in the RCUHardware set up of the projector address How to use your RCUUsing your RCU How to display a projector address?Input selection General Access Menu Items SourcePause key Analog Picture ControlsAdjustment mode Start UP of the Adjustment ModeStart Up of the Adjustment Mode Random Access Adjustment Mode Starting up the random access adjustment modeOverview ‘Random Access Adjustment’ mode Internal Cross Hatch Pattern Selecting Setup PatternColor Balance Random access adjustment mode selection menuPicture Tuning Sync Fast/Slow AdjustmentDisplay the projected image in that specific color PeakingColor Select Press Enter to display the color select menuFocusing FocusingGeometry Geometry AdjustmentsHorizontal Phase Adjustment PhaseRaster Shift Adjustment Left Right E-W Left-Right east-west AdjustmentsLeft Side Correction Left Keystone Left BOW Left Side CorrectionTOP Bottom N-S Top-Bottom north-south AdjustmentsSize Adjustment Vertical Linearity AdjustmentLinearity Blanking TOP Bottom Left Right Blanking AdjustmentsConvergence Adjustment Coarse Convergence AdjustmentsConvergence Vertical corners Fine Convergence AdjustmentsService Mode Starting up the Service modeOverview flowchart ‘Service’ mode Copy a Block IdentificationCopy a block IdentificationDelete ALL Blocks Deletion of blocksDeleting block by block Delete a BlockChange password Change LanguageTotal Run Time Undo R & B convergence mid All settings to midpositionUndo all settings to midpos Convergence midArrow key Axial Astigmatism correction Dynamic Astigmatism spot shape adjustmentCRT RUN in Cycle Projector Warm UP G2 AdjustmentCommon Settings 12C Diagnostics CRT run in cycleProjector Warm UP Projector warm upSource MESSAGES, WARNINGS, and FailuresFailure DTV-992 Ultra DTV-992RS 232 Control AppendixSending a Record single instruction STX Decimal values$02,$00,$00,$51,$0A,$00,$00,$00,$01,$5C SharpnessOverview Quick Guide to using the EYE-QTMsystemPreparing your EYE-QTM Easy-to-use, high precision automatic convergence systemEasy-to-use, high precision automatic geometry system Compact, built-in systemEYE-QTMMENU Access to EYE-QTMON-SCREEN MenusSetting the Configuration EYE-QTMSETUPFocusing the Camera Lens Centering the Camera Horizontally Centering the CameraTOUCH-UP on Source ON/OFF Centering the Camera VerticallyTOUCH-UP on Timer Adjusting Other SourcesReference Source Learning a Reference What is Being Measured by EYE-QTMOn Current Source Adjusting Screen SizeTOUCH-UP Align on Current SourceAlign from Midposition on Current Source On ALL Sources TOUCH-UP on ALL SourcesAlign on ALL Sources Error Messages Align from Midposition on ALL SourcesInterrupting the Automatic Convergence Process No Pattern Error Status Reporting Forced BreakStatus Forced break EYE-QTMDIAGNOSTICS APX-16 Page RUMA-003700 rev