Appendix 2

EYE-QTMDIAGNOSTICS

This option allows a check-up of the EYE-QTM

NOTE: Most errors that occur during the LEARN REFER- ENCE procedure or the beginning of the AUTOCONVER- GENCE procedure are caused by one of the following:

Lens cap not removed

Lens focus not performed properly Camera focus not performed properly Ambient light is too high Reference not learned properly

Blanking not set properly—must set blanking to each edge of screen border

If all else fails, run the diagnostics.

To start up the EYE-QTMDiagnostics:

Highlight EYE-QTMby pushing up or down keys of the control disc;

Press the <ENTER> button.

EYE-Q

TOUCH UP

AUTOCONVERGENCE

QUICK AUTOPICTURE

FULL AUTOPICTURE

EYE-Q SETUP

EYE-Q DIAGNOSTICS

EYE-Q

TM

 

DIAGNOSTICS

Interferance Test

TBD

Generic Test TBD

Sync Test

TBD

Ram Test

TBD

Ready and Config Test

After the <ENTER> button is pressed, the EYE-QTMDIAG- NOSTICS menu will be displayed and the Tests start instantly.

It includes check-ups on four items:

Interface Test;

Generic Test;

Sync Test;

Ram Test.

After completing each test, the status report will give the test result:

Pass; or

Failed plus the error number.

During the Interface Test, the following messages will dis- played one after another on the screen:

Ready and Config Test;

During the Generic Test, the following messages will be dis-

Ready and Config OK;

Config Ackn. Test;

played one after another on the screen:

Config Ackn. OK;

Config for Generic;

Full Config Test;

Full Config OK;

Config for Generic OK;

Interface Test OK.

Chipselects Test;

 

Chipselects OK;

In case of failures, the error message will be shown:

Addressability Test;

 

Addressability OK;

FAILED... Error 01; or

Crystal and Reset Test;

FAILED... Error 02; or

Crystal and Reset OK;

FAILED... Error 03;.

Generic Test OK

 

APX-15

Image 66
Contents DTV-992/992 Ultra Page Table of Contents Table of Contents APX-6 APP-3EYE-QTMDIAGNOSTICS Safety Instructions Installation InstructionsSafety Instructions Location and Function of Controls Rear Panel TerminologyFront Panel Terminology Control panel terminology Local KeypadRCU control panel terminology IR Transmission Indicator Switching On/Off AC Power mains Cord ConnectionPower Check ConnectionsSignal Input Connection to the Projector Start up with full white imagePort No Projector Input Press Digit Button Rgbs or RGsB input selection Connecting a RGB Analog source with composite syncConnecting a RGB Analog source with Tri-level sync RGB3S or RG3sB input selectionConnecting a Component source Connecting a Component source with Tri-level syncYYB-YS or R-YYsB-Y input selection Remote control YYB-Y3S or R-YY3sB-Y input selectionData communications Battery installation in the RCU ControllingHow to display a projector address? How to use your RCUUsing your RCU Hardware set up of the projector addressGeneral Access Menu Items Source Input selectionAnalog Picture Controls Pause keyStart UP of the Adjustment Mode Adjustment modeStart Up of the Adjustment Mode Random Access Adjustment Mode Starting up the random access adjustment modeOverview ‘Random Access Adjustment’ mode Selecting Setup Pattern Internal Cross Hatch PatternSync Fast/Slow Adjustment Random access adjustment mode selection menuPicture Tuning Color BalancePress Enter to display the color select menu PeakingColor Select Display the projected image in that specific colorFocusing FocusingPhase Geometry AdjustmentsHorizontal Phase Adjustment GeometryRaster Shift Adjustment Left-Right east-west Adjustments Left Right E-WLeft Side Correction Left Side Correction Left Keystone Left BOWTop-Bottom north-south Adjustments TOP Bottom N-SSize Adjustment Vertical Linearity AdjustmentLinearity Blanking Adjustments Blanking TOP Bottom Left RightConvergence Adjustment Coarse Convergence AdjustmentsConvergence Fine Convergence Adjustments Vertical cornersService Mode Starting up the Service modeOverview flowchart ‘Service’ mode Identification IdentificationCopy a block Copy a BlockDelete a Block Deletion of blocksDeleting block by block Delete ALL BlocksChange password Change LanguageTotal Run Time Convergence mid All settings to midpositionUndo all settings to midpos Undo R & B convergence midDynamic Astigmatism spot shape adjustment Arrow key Axial Astigmatism correctionCRT run in cycle G2 AdjustmentCommon Settings 12C Diagnostics CRT RUN in Cycle Projector Warm UPProjector warm up Projector Warm UPMESSAGES, WARNINGS, and Failures SourceFailure DTV-992 DTV-992 UltraAppendix RS 232 ControlSending a Record single instruction Decimal values STXSharpness $02,$00,$00,$51,$0A,$00,$00,$00,$01,$5CQuick Guide to using the EYE-QTMsystem OverviewCompact, built-in system Easy-to-use, high precision automatic convergence systemEasy-to-use, high precision automatic geometry system Preparing your EYE-QTMAccess to EYE-QTMON-SCREEN Menus EYE-QTMMENUEYE-QTMSETUP Setting the ConfigurationFocusing the Camera Lens Centering the Camera Centering the Camera HorizontallyCentering the Camera Vertically TOUCH-UP on Source ON/OFFTOUCH-UP on Timer Adjusting Other SourcesReference Source What is Being Measured by EYE-QTM Learning a ReferenceAdjusting Screen Size On Current SourceTOUCH-UP Align on Current SourceAlign from Midposition on Current Source On ALL Sources TOUCH-UP on ALL SourcesAlign on ALL Sources Error Messages Align from Midposition on ALL SourcesInterrupting the Automatic Convergence Process No Pattern Error Status Reporting Forced BreakStatus Forced break EYE-QTMDIAGNOSTICS APX-16 Page RUMA-003700 rev