■Alarm Setup (ALARM SETUP)
The digital disk recorder accepts alarm signals supplied from connected devices such as sensors or camera site equipment. The recorder itself also generates an alarm sig- nal when the preset motion detection is activated. Any alarm signal starts recording with the preset recording mode, field rate, and picture quality specified in the REC MODE menu described earlier. Alarm recording stops when the preset time has elapsed, the alarm [RESET] but- ton on the front panel is pressed, or the ALARM RESET IN signal is supplied from the connected device. The recorder outputs an alarm recovery signal from the rear panel.
| ALARM SETUP | |
ALARM | BUZZ | ON |
VIDEO | LOSS | ON |
MONITOR MODE |
| |
MULTI OUT | SPOT | |
SPOT | OUT | SPOT |
VMD SETUPO
●Alarm Buzzer (ALARM BUZZ)
Enables or disables buzzer beeping when an alarm oper- ates.
1.Move the cursor to ALARM BUZZ with the [D] or [C] button.
2.Rotate the JogDial to select ON or OFF. The default is ON.
ON: Buzzer beeps while alarm is active.
OFF: Buzzer does not beep.
●Video Loss (VIDEO LOSS)
Enables or disables video loss detection.
1.Move the cursor to VIDEO LOSS with the [D] or [C] button.
2.Rotate the JogDial to select ON or OFF. The default is ON.
ON: Enables the recorder to detect video loss.
OFF: Ignores video loss.
●Monitor Mode (MONITOR MODE)
This setting specifies whether to allow the display on the multiscreen monitor and spot monitor to change from the currently displayed picture to the alarmed channel when an alarm operates.
1.Move the cursor to MULTI OUT or SPOT OUT with the [D] or [C] button.
2.Select the parameter with the JogDial, and press the JogDial.
The default is SPOT.
SPOT: Switches to the picture of the alarmed channel.
OFF: Retains the previous display mode.
●Video Motion Detection (VMD SETUP)
A VMD or Video Motion Detector senses changes in the video signals within a preset area and supplies alarm out- put. When a change is detected, the recorder starts record- ing. The detection sensitivity and area are selected on this menu.
1.Move the cursor to VMD SETUPO with the [D] or [C] button, and press the JogDial. The VMD SETUP window opens.
| VMD SETUP |
CAM | SENS |
1 | OFF |
2 | LOWO |
3 | MIDO |
4 | HIGHO |
5 | OFF |
6 | OFF |
7 | OFF |
8 | OFF |
2.Move the cursor to the desired line.
3.Rotate the JogDial to select the desired parameter, and press the JogDial.
The default is OFF.
LOW: Low sensitivity
MID: Medium sensitivity
HIGH: High sensitivity
OFF: Motion detection is disabled.
The area setup window appears with an asterisk when other than OFF is selected. The asterisk represents the
37