Panasonic WJ-HD220 manual Setup Control, Miscellaneous Control, Data Log Control

Page 92

Setup Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Cursor Moves

DCR:n1n2

DCR

n1=A Right

 

 

 

n1=C Upward

 

 

 

n1=E Left

 

 

 

n1=G Downward

 

 

 

n2=1 Move a step

 

 

 

n2=2 Move multi steps

 

 

 

n1n2=PD Move to lower layer

 

 

 

n1n2=P+ Move to upper layer

 

 

 

n1n2=P- Turn a newer page

 

 

 

n1n2=PU Turn an older page

 

 

 

 

Key Lock

MKL:n

MKL

n=0 Lock OFF

 

 

 

n=1 Lock ON

Recording Event

MRM:n

MRM

n=0 Normal recording

Setup

 

 

n=1 Internal timer recording

 

 

 

n=2 External timer recording

Summer Time Setup

MST:n

MST

n=0 Standard time

 

 

 

n=1 Summer time

 

 

 

 

Setup

MSU:n

MSU:n

n=0 End setup

 

 

 

n=1 Begin setup

Date&Time Setup

TSU:yyyymmddhhnn

TSU

yyyy=Year

 

 

 

mm=Month

 

 

 

dd=Day

 

 

 

hh=Hour (24-hour system)

 

 

 

nn=Minute

 

 

 

 

Miscellaneous Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

OSD Show/Hide

DIN:n

DIN

n=+ Toggle

 

 

 

n=0 Hidden

 

 

 

n=1 Shown

 

 

 

 

 

Communication Check

RCK

RCK

 

 

Time&Date Search

ZTS:yyyymmddhhnnss

ZTS

yyyy=Year

 

 

 

mm=Month

 

 

 

dd=Day

 

 

 

hh=Hour (24-hour system)

 

 

 

nn=Minute

 

 

 

ss=Second

Time&Date

ZTL:n

ZTL

n=7

Search window displayed

Search Window

 

 

n=0

Search window hidden

 

 

 

 

 

Alarm Log

ZTM:n

ZTM

n=1

Alarm log search displayed

Search Window

 

 

n=0

Alarm log search hidden

Data Log Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Log Total Size Inquiry

ILB:k

ILB:k:bbbbb

k=0 Alarm log

 

 

 

bbbbb=00001 to 09999 (in decimal)

Log Erase

ILC:n

ILC:n

n=0 Alarm log

 

 

 

n=1 System log

 

 

 

 

Log Recorded

ILQ:k

ILQ:k:bbbbb:ddddd:(:E)

k=0 Alarm log

Size Inquiry

 

 

bbbbb=00001 - 09999 (Oldest log)

 

 

 

ddddd=00001 - 09999 (Size of log)

 

 

 

E=Overwrite

Log Readout

ILR:k:sssss:mmmmm

ILR:k:<log data s1>s1

k=0 Alarm log

 

 

<log data s2>s2

sssss=00001 - 09999 Start Address

 

 

<log data sn>F

mmmmm=00001-00100

 

 

 

Decimal # of log

 

 

 

<log data sn>=yymmddhhnnss

 

 

 

sn=0-9 and F Cyclic number

 

 

 

(F is put at data end)

92

Image 92
Contents Operating Instructions English Version Important Safety Instructions Contents Trademarks FeaturesPreface Precautions Front View 4HDD Access Indicator HDD 5FULL Indicator Full6Error indicator Error 7Stop and Setup/Escape Button Stop SETUP/ESC@6Audio Out @7Video Out Video OUTRear View About mounting InstallationPlaces to avoid Mounting in the Rack Connections & DIP SW Setting Basic SystemPS Data System Personal computers can access the WJ-HD220 via the network Network SystemALARM/REMOTE Connection Connection with the Camera SiteConnection with the Monitors System Camera ConnectionExternal Recording Connection Alarm ConnectionTime Adjusting Connection PS Data Connection Serial Port ConnectionsRS-232C Connection 10/100BASE-T Port Connection Case 2 Exclusively with System ControllerSystem Mode Data Port TerminationSetup Procedures Prior to SetupTurning On the Power Turning Off the PowerButtons and Dials Used for Setup Displaying WJ-HD220 Main MenuClosing WJ-HD220 Main Menu JogDial Counter-clockwise Decreases the parameterPROG2 Setup Menu TreeInitializing All Contents & Setup Data Initializing Setup DataInitializing Settings for Network Setup Menu InitializingMain Menu WJ-HD220 Main Menu Timer Recording Setup Timer RECProgram 1-4 Setup PROG1-4 Pre-alarm Recording PRE ALM REC Recording Mode Setup PROG1-4 SETUP, noAlarm Recording Mode Setup ALM Post-alarm Recording Post ALM REC Trigger Action Setup Trigger Action SetupCamera Recording Setup CAM REC Setup Dynamic Recording Dynamic RECManual Recording Setup REC Externally Specified Recording Mode EXT REC SetupDisplay Setup Display Setup Clock ClockTime & Date Position TIME&DATE Posi Time & Date Embedded TIME&DATE EMBStatus Display Status Disp Status Position Status PosiDisk Check HDD Check Disk Capacity Warning HDD FullRemote LED Remote LED ~ 9 a ~ Z ! % ? ← → ↑ ↓ System Setup System SetupCamera Title Camera Title Skip Alarm Recall Setup Password Lock Setup Password LockKeylock Buzzer Setup Keylock Buzz Simultaneous Recording & Playback Simul REC&PLAY Disk End Mode SetupAlteration Detection Setup Play Priority Setup Play Priority Time Adjust SetupAuto Erasing Setup Disk End Buzzer Disk END BuzzResolution Resolution HDD Safety Mode HDD Safety Mode Alarm Setup Alarm Setup Alarm Buzzer Alarm BuzzMonitor Mode Monitor Mode Video Motion Detection VMD SetupProtocol Protocol Communication SetupSerial Port Setup Baud Rate Baud Rate Data Bit Data BITWait Time Wait Time Control Unit Address CTL-UNIT Address only for PS DataNetwork Setup Network Setup Alarm Data Alarm Data exclusive to PS DataLine Speed Line Speed Assignable numbersSwitcher Setup Switcher Setup Multiscreen Sequence Setup Multi SEQ Setup Spot Sequence Setup Spot SEQ SetupCamera View Setup Camera View Setup Available durations 2-30SSystem Information Language Language System Log System LOGOperating Procedures On the Spot MonitorSelecting the Spot Monitor Viewing a Single LiveOn the Multiscreen Monitor Selecting the Multiscreen MonitorZooming a Single Live Viewing a Quad Live SequenceAlarm Input Alarm OutputResetting Alarm Suspending Alarm Input Alarm Log Recall & SearchTo Erase Log Internal Timer RecordingTo Search for Playback Manual Recording Power-on RecordingAlarm Recording Alarm Search Playback Normal PlaybackSkip Playback Step PlaybackTime & Date Search Playback Picture record of a specified time and date is played backPassword Verification Enabling Button LockWJ-HD220 Preparations System RequirementsBrowser DisplayConnection Direct Connection with a PCSystem Expansion Connection with a Client PC via HubRecorder Status Displayed Quality Main Page and Control PanelAbout Picture Quality WJ-HD220 Setup To Access Setup MenusTimer Setup Timer Setup Timer Recording Timer RECProgram Assignment Timer REC Programming Program SetupRecording Mode Setup PROG1-4 NO.1-4 Setup Assignable programs PROG1 PROG4, OFFTrigger Action Setup Trigger Action Setup Camera Preset Position Preset Camera Recording Setup RECManual Recording Setup REC Setup Clock Setup Clock Setup Time and Date Position TIME&DATE PositionTime & Date Embedded TIME&DATE Status Display Status DisplayCamera Title Camera Title Disk End Mode Disk END Mode Time Adjusting Time AdjustingAlteration Detection Alter Detect Disk End Buzzer Disk END BuzzerVideo Motion Detector Setup VMD Setup VMD Area Setup VMD Area SetupAlarm Data Alarm Data Protocol Selection Protocol SelectBaud Rate Baud Rate Data Bit Data BITCamera System Setup Only for PsdataSimple Network Management Protocol Domain Name Service Domain Name ServiceDynamic DNS Dynamic DNS Common Setup Common Setup Multiscreen Sequence SetupSpot-screen Sequence Setup Camera View Setup Camera View SetupMulti Sequence Setup Multi Camera View Setup Camera View SetupCamera Channel Camera CH Time TimeSystem Information System Information Error Information FTP, SMTP, Ddns Host Setup Host Setup Network ConfigurationUser Setup User Setup FTP Send by Periodic Timer FTP Send by Periodic Timer FTP Client Setup FTP Client SetupBasic Setup Basic Setup Mail Setup Mail Setup Alarm Mail Setup Alarm Mail SetupSet Mail Address SET Mail Address Delete Mail Address Delete Mail AddressNetwork Video Setup Live & Playback Image Setup Live & Play Image SetupLive Sequence Setup Live Sequence Setup Video Rate Video RateOperating WJ-HD220 Main PanelStart Button Start 0Start Time Display Area1End Button END 2End Time Display AreaMain Control Panel Camera Control View Button Camera Control View PAN/TILT ControlAlarm List Http Download and Viewing Images Phenomenon Cause What to do TroubleshootingWhen accessing via the network Specifications & Appendix Specifications Standard Accessories Remote Control from System Controller AppendixSearch Time and date selectionFor Time&Date search Implement Time&Date RS-232C Communication Protocol Transmission CommandResponse Command Basic Operation Command TableAlarm Control Data Log Control Setup ControlMiscellaneous Control Media Control InquiryPower-on Procedures HDD MaintenanceWhen to Maintain HDD Who to Maintain HDD When Full Indicator is Lit Resetting Disk End When Error Indicator is LitAuto-remove Disk MenuAbbreviation Status Required Capacity Removing Logical Link Remove Link Formatting HDD HDD FormatRestarting Restart NOW Formatting HDD Format SET DoneMail Contents For More Security Network SecurityWJ-HD220 Security Function Network Error Information Smtp ErrorsFTP Errors Type Message DetailsDdns Errors 102Ns0805-0 V8QA6335AN Imprimé en Chine