●Auto Reset
The activated alarm event is reset when the AUTO RESET time has elapsed, or the lost video has been recovered. The ALARM indicator changes from blinking to a steady light.
●External Reset
The activated alarm event except video motion detection, is reset when the recorder receives an external reset signal from the connected device via the REMOTE/ALARM con- nector on the rear panel.
The ALARM indicator changes from blinking to a steady light.
●Pressing REC STOP Button
Pressing the [REC STOP] button resets alarm status and recording when MONITOR MODE is set to OFF. When SPOT is set, only the [ALARM RESET] button will reset alarm status and recording.
REC STOP
■Suspending Alarm Input
This function may be convenient during setup procedures. When enabled, any alarm input is ignored and the recorder performs as follows.
•The alarm event will be stored in the alarm log.
•The recorder enters alarm recording.
•The alarm buzzer does not sound.
•The SUSPEND indicator lights up.
1.Hold down the alarm [RESET] button and [LOCK] but- ton simultaneously to enable the suspension function. The SUSPEND indicator lights up.
ALARM TIMER
SUSPEND REMOTE
RESET LOCK
2.Do the same as above to reset the suspension function. The indicator turns off.
■Alarm Log Recall & Search
The ALARM RECALL window displays the alarm event log in chronological order with event numbers, dates, times, and the activation sources. A maximum of 9 999 events can be stored, and older records will be erased when more events arise.
ALARM RECALL YEAR03 | |||
NO. | DATE | TIME | ALM |
1543 | OCT30 | 23:58:12 | T1 |
1542 | OCT30 | 23:52:54 | V2 |
1541 | OCT30 | 23:40:29 | V3 |
1540 | OCT30 | 23:39:50 | T4 |
1539 | OCT30 | 23:35:41 | P2 |
1538 | OCT30 | 23:30:22 | P1 |
1537 | OCT30 | 23:25:55 | T2 |
1536 | OCT30 | 23:21:09 | T2 |
(TOTAL | 1543EVENTS) |
| |
TO SEARCH PUSH T&D KEY | |||
ALARM RECALL YEAR03 | |||
NO. | DATE | TIME | ALM |
0003 | OCT20 | 23:52:54 | V2 |
0002 | OCT20 | 23:51:54 | V2 |
0001 | OCT20 | 23:50:54 | V2 |
PUSH JOG→DATA CLEAR | |||
(TOTAL | 1543EVENTS) |
|
TO SEARCH PUSH T&D KEY
T:Alarm terminal was activated.
V:VMD was activated.
P:Alarm event notification from the PC.
Note: In some cases the log displayed in the ALARM RECALL list may apply to the previous alarm record that was overwritten after selecting CONTINUE for the DISK END MODE. This is because the alarm log is updated later than the image data.
●To Browse through Log
1.Hold down the JogDial for 2 seconds. The monitor dis- plays the ALARM RECALL list.
2.Rotate the JogDial to scroll up or down the page. Scrolling speed is selected in the menu setup.
3.Hold down the JogDial for 2 seconds to quit the ALARM RECALL list and go back to the previous window.
●To Sort by Channel
1.Hold down the JogDial for 2 seconds to display the ALARM RECALL list. The log of all channels appears.
2.Press the desired channel [CAM SEL] button. The indi- cator on the button lights up, and only the log of the selected channel will be displayed.
3.Press another channel button to select a new channel.