■Connection with the Uninterrupted Power Supply (UPS)
•The figure shows an example of how to connect a UPS as protection against power failures.
•When a power failure detect input is received from the UPS, the disk recorder's power failure process starts to process this signal to turn off its power supply.
•When the power failure process is completed, the disk recorder outputs a signal to the UPS.
•When the UPS receives the completion signal from the disk recorder, the disk recorder's power is turned off
Power Failure Process | UPS Shut Down |
Completion Output | |
Power Failure Detect Input | Line Fail signal |
(Normally Open) |
Disk Recorder | Ground | |
|
(19) | (17) | (16) |
CONTROL |
|
Common
CBefore connecting the UPS, refer to the manual of your UPS.
Uninterrupted
Power Supply
to AC outlet
Power Cable
■Connection with CONTROL output
•Signal outputs (Pins
•The figure below shows an example of how to connect an alarm output (Pin #6) to warn of low remaining HDD capacity.
| (Remaining HDD Capacity Alarm Output) |
(6) | (15) Ground |
Alarm Device
Relay, etc.
CONTROL Input/Output