Panasonic WJ-HD500A Connection with the Extension Units, Scsi Connection, Switch Setting, Mode

Page 21

Connection with the Extension Units

SCSI Connection

The Digital Disk Recorder WJ-HD500A controls the extension units through the SCSI chain.

1. Connect the supplied SCSI cable between

the EXT STORAGE port on the WJ-HD500A

Cable

Digital Disk Recorder

WJ-HD500A

SCSI ID = 6 and 7

IN

 

EXT STORAGE

 

 

 

COPY

 

 

 

GEN-LOCK OUT

SIGNAL GND

 

 

SPOT

 

 

 

 

 

 

 

 

 

DATA

REMOTE(WV-CU50)

 

10/100

 

AC

OUT

 

 

 

 

 

 

 

 

 

 

SERIAL

 

 

IN

OUT

 

 

CONTROL

 

 

ALARM

 

 

MODE

 

 

 

 

 

 

 

MULTI SCREEN OUT AUDIO

14

12

11

9

8

6

5

4

3

2

1

 

16

15

13

10

7

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

POWER

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

 

 

and the EXT IN port on the 1st extension

unit.

2. Connect the supplied SCSI cable between

the EXT OUT port on the 1st extension unit

and the EXT IN port on the 2nd extension

unit.

Repeat connections in the same manner for

all additional extension units.

3. The 3rd extension unit must be a WJ-

SCSI

EXT IN

EXT OUT

 

 

 

 

GND

NC

SCSI ID

 

 

 

 

TERMINATOR

 

SCSI Cable

EXT IN

EXT OUT

 

 

 

 

GND

NC

SCSI ID

 

 

 

 

TERMINATOR

 

Extesion Unit #1 WJ-HDE500 SCSI ID = 5

AC IN

POWER

 

ON

 

OFF

 

SIGNAL GND

Extesion Unit #2 WJ-HDE500 SCSI ID = 4

AC IN

POWER

 

ON

 

OFF

 

SIGNAL GND

SCSI Cable

EXT IN

EXT OUT

 

 

 

 

GND

NC

SCSI ID

 

 

 

 

TERMINATOR

 

SCSI Cable

EXT IN

EXT OUT

 

 

 

 

GND

NC

SCSI ID

 

 

 

 

TERMINATOR

 

Extesion Unit #4 WJ-HDE500 SCSI ID = 2

AC IN

POWER

 

ON

 

OFF

 

SIGNAL GND

Extesion Unit #5 WJ-HDE500 SCSI ID = 1

AC IN

POWER

 

ON

 

OFF

 

SIGNAL GND

HDE505 if a further extension unit is con- nected. Use WJ-HDE500if the 3rd unit is located at the end of the SCSI chain.

Up to 6 extension units can be added.

CableSCSI

EXT IN

EXT OUT

 

 

 

 

 

GND

NC

SCSI ID

 

 

 

 

 

TERMINATOR

 

 

 

 

 

 

 

 

Extesion Unit #3 WJ-HDE500 or WJ-HDE 505* SCSI ID = 3

AC IN

POWER

 

ON

 

OFF

 

SIGNAL GND

Cable

 

Extesion Unit #6

SCSI

 

 

SCSI ID = 0

 

 

WJ-HDE500

EXT IN

 

 

EXT OUT

 

 

 

GND NC

AC INPOWER

SCSI ID

ON

 

TERMINATOR

OFF

SIGNAL GND

*Use a WJ-HDE505 for the 3rd unit position if additional units are installed. Use a WJ-HDE500 if the 3rd position is the end of the SCSI chain.

Switch Setting

Data termination and SCSI number settings are required, as shown below.

1.Set the MODE switch #2 on the rear of the WJ-HD500A to ON when connecting with an extension unit.

2.Set the SCSI ID number for each unit by pressing the

[–]or [+] button on the rear of the Extension Unit. 0 to 5 are applicable to the extension units.

Note: SCSI ID 6 and 7 are reserved for WJ-HD500A Disk Recorder.

3.Set the termination switches on the rear of the Extension Units to ON or OFF.

ON: Is applied to the extension unit located at the end of the SCSI chain.

OFF: Is used for units other than the end unit.

1 2 3 4

ON

MODE

SCSI ID

1

+

TERMINATOR

ON

OFF

21

Image 21
Contents Operating Instructions English Version Contents Preface FeaturesReliable recording of events Easy image searchFully charge up the backup battery PrecautionsDo not drop metallic parts through slots Do not attempt to disassemble the applianceFront View @8Setup/Escape Button SETUP/ESC @4Alarm Search Button Alarm Search1Numeric Buttons 1 2Set Button SET#1Hard Disk Drive Indicator HDD #0Full Indicator Full$1Multiscreen Output Connector Multiscreen OUT $2Spot Output Connector Spot OUT$9Mode Selector Mode $7Alarm Port Alarm2Gen-lock Output Connector GEN-LOCK OUT 8Power Switch Power ON/OFFWV-CU50 Remote Controller 1Link Indicator Link 9Alarm Search Button Alarm SearchBlinking Pause mode 0JogDial 6Electronic Zoom Button EL-ZOOMInstalling the Optional Hard Disk InstallationInstalling the Optional Motion Detector Board Installing the Optional Network Board Mounting into the Rack Basic System ConnectionsSystem Expansion Shown below are examples of system connectionsConnection with the Remote Controller Connection with the Camera SitesConnection with the Monitors Alarm Alarm Port ConnectionControl Port Connection Connection with Control output Connection with the Uninterrupted Power Supply UPSConnection with the Extension Units Switch SettingScsi Connection ModeSwitch Settings Connection with the DVD Extension UnitConnection with the DVD Extension Unit without HDD Scsi ID=0 to Connection with the DVD Extension Unit with HDDConnection to PSData Compatible Equipment Mode Selector Setting10/100BASE-T Port Connection Serial Port ConnectionPreparations Power UP Procedure Formatting the Hard Disk 1DISK Format Formatting the DVD-RAM Disk Mirroring Function To deactivate the mirror function Disk Remove Spot and Multiscreen Monitor Monitors and DisplaysStatus Display Time DisplaySystem Status Display Format Error orGroup Display Electronic Zoom DisplayHard Disk Timer RecorderManual Recorder Emergency RecorderTime Lapse Recording Multi Shot RecordingDynamic Recording is set to OFF Dynamic Recording is set to ALM-ONLY One Shot RecordingSetup Procedures Displaying the Setup Menu Setup MenuProgramming Menu Setup Setup Timer Setting Recording SetupDisplay Setup Communication Setup Timer Setting Recording Quality Setup Recording SetupVideo Pixels Resolution Color Mode SettingGroup Title Setup Group SetupCamera Assignment SpacePlayback Mode Setup Thumbnail Display SetupShuttle Speed Setup Recording of the Title DisplayHard Disk End Setup Manual Recording Mode Setting→ Manual with Audio → Manual Without Audio → Event Recording Manual Recording Program Timer Alarm Active Mode Manual RecordingSpecial Day Timer Time Lapse Recording Internal Timer External Program TimerEvent Recording Alarm Active ModeMulti Shot Recording Internal Timer One Shot Recording Internal Timer Emergency Recording Time Lapse Recording Sequence Setup Multiscreen Monitor Multiplexer SetupLive Sequence Pattern Setting Live SequenceQuad Shift Setting Quad Pattern SetupSequence Timing Setting Group Multi Sequence Setting Sequence Setup Spot MonitorAuto Skip Setting Live Sequence Pattern SettingPower on Setting Multiscreen Monitor Power on Setting Spot MonitorSequence Timing Setting Secret View Setting Alarm Port Setting Alarm SetupAlarm Auto Reset Setting Alarm Output SettingAlarm Buzzer Setting Video Loss Alarm SettingVideo Motion Detector Setting Alarm Mode on the Spot Monitor Alarm Mode on the Multiscreen MonitorCamera Title Setup Display SetupDisplay Setting Multiscreen Monitor Clock DisplayAlarm Display Setting Title Display Setting Spot MonitorTitle Display Status DisplayTitle Display Position Setting Clock and Status Display Position SettingPS Data Setup Communication SetupUnit Address Setting Baud RateInput Camera Number Setup Alarm DataParity Check Stop BitRS-232C Setup Network Setup Clock Setup System SetupTime Adjustment Setting SET TimeBuzzer Setting Password Lock SettingUser Defined Setting Auto Button Locked SettingDisk Space Indicator Disk ManagementDisk Information System Information Error ReportDVD Drive Setup Alarm Recording BackupDVD Format Emergency Recording Backup DVD Disk End SetupDisk Space Display Operating Procedures Controlling the Spot Monitor Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Spot LiveControlling the Multiscreen Monitor Selecting the Multiscreen MonitorZooming Single Spot Live Group Single Sequence Live Multiscreen Spot Live Multiscreen SelectAll Input Display with Quad Shift Off All Input Display with Quad Shift On Group Display Multi Sequence LiveGroup Multi Sequence Multi Group setting Quad settingAlarm Control Function Alarm InputAlarm Operation Alarm Suspension Alarm ResetManual Reset Auto ResetPower-on Time Lapse Recording Internal Timer RecordingRecording Manual RecordingAlarm Recording Alarm Recording for Manual and Power-on RecordingSet to ALM-ONLY Alarm Recording for Internal Timer Modes Set to ALM-MULTITime Lapse Recording Emergency Recording Basic Playback PlaybackStop Forward or Backward searchSearch Record Function Alarm jump searchJump search Record ListAlarm Log Search DisplayTime & Date Search Display on the Monitor Single and Multiscreen Spot PlaybackZooming Single Spot Playback REC Preview Displaying Camera and Playback ImageJogDial Backup FunctionDisplay Auto Erase Function Data Erase FunctionManual Erase Function To release this function, follow the procedure below Button Locked FunctionLock Playback of Backup Data Standard Accessory SpecificationsGeneral Input and OutputPanasonic Canada Inc Addendum