Panasonic WJ-HD500A manual One Shot Recording Internal Timer

Page 53

7.Move the cursor to the DYNAMIC REC parameter by pressing the D or C button, then select the recording pattern for post-recording by pressing the + or - but- ton.

OFF: Records the images assigned to group inputs, including the one that has activated the alarm (the same as pre-recording).

ALM-ONLY:Records the particular image that has acti- vated the alarm.

The factory default setting is OFF.

8.Move the cursor to the AUTO COPY parameter by pressing the D or C button, then select alarm backup mode by pressing the + or - button.

OFF: Disables alarm data backup.

ON: Enables alarm data backup. The factory default setting is OFF.

9.Press the SETUP/ESC button to return to the previous program number menu.

One Shot Recording (Internal Timer)

As described before, the One Shot Recording is an event recording function reacting to an alarm input.

It records the number of particular images that have acti- vated the alarm.

These items let you determine the recording parameters for One Shot Recording assigned in the program number menu.

(continued from Program Timer)

1.Select the recording mode O/S in the program number menu by pressing the + or - button, then press the SET button.

The selected One Shot Recording menu as shown below appears on the monitor screen.

3-1-1-1 PROG1-NO1-G1 REC SETUP

O/S(EVENT:ONE SHOT)

 

TRIGGER ACTION

REC+ALM

REC MODE

 

REC RATE

15FPS

REC QUALITY

SUPER FINE

PICTURES

16

AUTO COPY

OFF

2.Move the cursor to the TRIGGER ACTION parameter in the menu by pressing the D or C button, then select an active mode for group cameras when an alarm is received by pressing the + or - button.

REC+ALM: Enables alarm recording and alarm activa- tion.

REC: Enables only alarm recording.

The ALARM display on the monitor is also disabled. The factory default setting is REC+ALM.

3.Move the cursor to the REC RATE parameter in the menu by pressing the D or C button, then select the desired recording rate by pressing the + or - button.

1 - 60FPS: Records the selected number of the freeze image per second.

The factory default setting is 15FPS.

Notes:

The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table.

FIELD/FRAME

CAMERA GENLOCK

REC RATE

FIELD

ON

60FPS

 

OFF

30FPS

FRAME 3DIM

ON

10FPS

ON

OFF

10FPS

FRAME 3DIM

ON

30FPS

OFF

OFF

15FPS

“FPS” indicates as field per second or frame per second when the FIELD/FRAME parameter is set to FIELD or FRAME in the menu.

4.Move the cursor to the REC QUALITY parameter by pressing the D or C button, then select the desired image quality by pressing the + or - button.

SUPER FINE: For enhanced sharpness (Compression Rate 1/6)

FINE: For fine image quality (Compression Rate 1/10)

NORMAL: For normal image quality (Compression Rate 1/16)

EXTENDED: For extended time recording quality (Compression Rate 1/25)

The factory default setting is SUPER FINE.

5.Move the cursor to the PICTURE parameter by pressing the D or C button, then select the number of freeze images to be recorded by pressing the + or - button.

4 to 60: Records the selected number of freeze images for One Shot Recording.

The factory default setting is 16.

6.Move the cursor to the AUTO COPY parameter by pressing the D or C button, then select an alarm back- up mode by pressing the + or - button.

OFF: Disables backup for alarm recording.

ON: Enables backup for alarm recording. The factory default setting is OFF.

7.Press the SETUP/ESC button to return to the previous program number menu.

55

Image 53
Contents Operating Instructions English Version Contents Preface FeaturesReliable recording of events Easy image searchFully charge up the backup battery PrecautionsDo not drop metallic parts through slots Do not attempt to disassemble the applianceFront View @8Setup/Escape Button SETUP/ESC @4Alarm Search Button Alarm Search1Numeric Buttons 1 2Set Button SET#1Hard Disk Drive Indicator HDD #0Full Indicator Full$1Multiscreen Output Connector Multiscreen OUT $2Spot Output Connector Spot OUT$9Mode Selector Mode $7Alarm Port Alarm2Gen-lock Output Connector GEN-LOCK OUT 8Power Switch Power ON/OFFWV-CU50 Remote Controller 1Link Indicator Link 9Alarm Search Button Alarm SearchBlinking Pause mode 0JogDial 6Electronic Zoom Button EL-ZOOMInstalling the Optional Hard Disk InstallationInstalling the Optional Motion Detector Board Installing the Optional Network Board Mounting into the Rack Basic System ConnectionsSystem Expansion Shown below are examples of system connectionsConnection with the Monitors Connection with the Remote ControllerConnection with the Camera Sites Alarm Alarm Port ConnectionControl Port Connection Connection with Control output Connection with the Uninterrupted Power Supply UPSConnection with the Extension Units Switch SettingScsi Connection ModeConnection with the DVD Extension Unit without HDD Switch SettingsConnection with the DVD Extension Unit Scsi ID=0 to Connection with the DVD Extension Unit with HDDConnection to PSData Compatible Equipment Mode Selector Setting10/100BASE-T Port Connection Serial Port ConnectionPreparations Power UP Procedure Formatting the Hard Disk 1DISK Format Formatting the DVD-RAM Disk Mirroring Function To deactivate the mirror function Disk Remove Spot and Multiscreen Monitor Monitors and DisplaysStatus Display Time DisplaySystem Status Display Format Error orGroup Display Electronic Zoom DisplayHard Disk Timer RecorderManual Recorder Emergency RecorderDynamic Recording is set to OFF Time Lapse RecordingMulti Shot Recording Dynamic Recording is set to ALM-ONLY One Shot RecordingSetup Procedures Displaying the Setup Menu Setup MenuDisplay Setup Communication Setup Programming Menu SetupSetup Timer Setting Recording Setup Timer Setting Recording Quality Setup Recording SetupVideo Pixels Resolution Color Mode SettingGroup Title Setup Group SetupCamera Assignment SpacePlayback Mode Setup Thumbnail Display SetupShuttle Speed Setup Recording of the Title Display→ Manual with Audio → Manual Without Audio → Hard Disk End SetupManual Recording Mode Setting Event Recording Manual Recording Program Timer Alarm Active Mode Manual RecordingSpecial Day Timer Time Lapse Recording Internal Timer External Program TimerEvent Recording Alarm Active ModeMulti Shot Recording Internal Timer One Shot Recording Internal Timer Emergency Recording Time Lapse Recording Sequence Setup Multiscreen Monitor Multiplexer SetupLive Sequence Pattern Setting Live SequenceSequence Timing Setting Quad Shift SettingQuad Pattern Setup Group Multi Sequence Setting Sequence Setup Spot MonitorAuto Skip Setting Live Sequence Pattern SettingSequence Timing Setting Power on Setting Multiscreen MonitorPower on Setting Spot Monitor Secret View Setting Alarm Port Setting Alarm SetupAlarm Auto Reset Setting Alarm Output SettingVideo Motion Detector Setting Alarm Buzzer SettingVideo Loss Alarm Setting Alarm Mode on the Spot Monitor Alarm Mode on the Multiscreen MonitorCamera Title Setup Display SetupDisplay Setting Multiscreen Monitor Clock DisplayAlarm Display Setting Title Display Setting Spot MonitorTitle Display Status DisplayTitle Display Position Setting Clock and Status Display Position SettingPS Data Setup Communication SetupUnit Address Setting Baud RateInput Camera Number Setup Alarm DataParity Check Stop BitRS-232C Setup Network Setup Clock Setup System SetupTime Adjustment Setting SET TimeBuzzer Setting Password Lock SettingUser Defined Setting Auto Button Locked SettingDisk Information Disk Space IndicatorDisk Management System Information Error ReportDVD Format DVD Drive SetupAlarm Recording Backup Disk Space Display Emergency Recording BackupDVD Disk End Setup Operating Procedures Controlling the Spot Monitor Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Spot LiveZooming Single Spot Live Controlling the Multiscreen MonitorSelecting the Multiscreen Monitor Group Single Sequence Live All Input Display with Quad Shift Off Multiscreen Spot LiveMultiscreen Select All Input Display with Quad Shift On Group Display Multi Sequence LiveGroup Multi Sequence Multi Group setting Quad settingAlarm Operation Alarm Control FunctionAlarm Input Alarm Suspension Alarm ResetManual Reset Auto ResetPower-on Time Lapse Recording Internal Timer RecordingRecording Manual RecordingSet to ALM-ONLY Alarm RecordingAlarm Recording for Manual and Power-on Recording Time Lapse Recording Alarm Recording for Internal Timer ModesSet to ALM-MULTI Emergency Recording Basic Playback PlaybackStop Forward or Backward searchSearch Record Function Alarm jump searchJump search Record ListTime & Date Search Alarm Log SearchDisplay Zooming Single Spot Playback Display on the MonitorSingle and Multiscreen Spot Playback REC Preview Displaying Camera and Playback ImageJogDial Backup FunctionDisplay Auto Erase Function Data Erase FunctionManual Erase Function Lock To release this function, follow the procedure belowButton Locked Function Playback of Backup Data Standard Accessory SpecificationsGeneral Input and OutputPanasonic Canada Inc Addendum