JVC BR-HD50E instruction manual Cleaning tape, Condensation, Operating environ, Ment

Page 13
Head drum
Videotape

Cleaning tape

Use a JVC cleaning tape.

Follow the instructions below for using the clean- ing tape.

1.Run the tape for 10 seconds in the PLAY mode. (Thereafter, it stops automatically and enters the STOP mode.)

After loading the cleaning tape, press the PLAY button.

2.For a single cleaning session, it can be repeated up to 4 times.

3.Refer to the following table as a guide for cleaning.

Note

zUnder low humidity conditions, (10% RH to 30% RH), perform head cleaning at intervals of half of the periods stated in the table.

zIf an M-DV80 tape is used immediately after cleaning, the message, “HEAD CLEANING REQUIRED!” may not disappear. It does only after the tape has run for some time.

zUse the cleaning tape at room temperature (10°C to 35°C).

zInstructions for using the cleaning tape stated on a sheet inside its storage case may be dif- ferent in part from those stated here.

Follow the instructions in this manual.

Operating environ-

Low temperature

 

Room temperature

High temperature

ment

5°C to 10°C

 

10°C to 35°C

35°C to 40°C

 

 

 

 

 

Frequency of cleaning

1 to 2 times every

5

1 to 2 times every 20 to

1 to 2 times every 5

 

hours

 

30 hours

hours

 

 

 

 

 

Condensation

When this unit is moved from a cold to a warm place abruptly, the vapor in the warm air will come into contact with the head drum or the tape guides, which are not warmed enough. When chilled, the vapor turns into droplets of water. This state is known as condensation. When condensation occurs, the videotape adheres to the head drum or the tape guides and will be damaged.

Condensation occurs on this unit in the fol- lowing circumstances:

* It is moved abruptly from a cold place to a warm place.

* It is used in a place immediately after the heater has been turned on, or when cold breeze from an air-con- ditioner blows onto it.

*It is used at a place of high humidity.

When a cassette tape is loaded, do not transport e.g., from a cold outdoor place to a warm room thus subjecting the unit to drastic temperature changes. After moving the unit, do not use it until the inner mechanism stabilizes.

When condensation occurs, the monitor displays the following warning:

CONDENSATION ON DRUM

Leave the unit with the power ON and wait until the WARNING message disappears.

Prevention of condensation

When transporting BR-HD50 from a cold to a warmer place abruptly, first remove the cassette tape. Then place BR-HD50 in a plastic bag and seal it before transporting.

Take out BR-HD50 from the sealed plastic bag only after it has the same temperature as the surroundings.

E-9

Image 13
Contents For Customer Use BR-HD50Important Safeguards Remarque InformationInformation for Canada Renseignement Pour Canada European Union Port Cable LengthBusiness users Other Countries outside the European Union For Your Safety Please Read the Following Text Carefully Power SystemMust be Earthed For Continental EUROPE, ETC For U.K. onlyHDV 720p format Compatible with 60Hz/50Hz HD signal for- matCompatible with DV format Compatible mechanism for standard/mini DV cassettesTable of Contents Remarks of usage Introduction„ Erasure prevention Cassette tapeStandard DV cas- z Mini DV cassettes settes LA-DV276M-DV63PRO LA-DV186M-DV63HD LA-DV124„ HD signal format „ HDV and DV signal input/outputHDV and DV format „ Recording time „ HDV 720p and DV format„ HD video output „ Regular maintenance Regular maintenance„ Head cleaning Condensation Cleaning tapeOperating environ Ment1Cassette loading slot/LED Names and Functions of Parts2OPERATE button/LED 3EJECT button„ Pause button/LED „ Play button/LED„ FF button/LED „ Stop button/LED7COUNTER switch 5REMOTE/LOCAL switch 6INPUT Select switch„ Dvcam indicator light 8IEEE1394 IEEE1394 terminal switch„ 60 indicator light „ 50 indicator lightHSpecial functions/Setting buttons FRESET buttonSetting screens EMENU button„ SEARCH+/S button „ BLANK/P button„ SEARCH-/Q button „ SET button3VIDEO Line OUT terminal BNC 2VIDEO Y/C in terminal 4-PINRear panel 5COMPONENT OUT Component sig- nal output terminal BNC×3 0HDMI OUT Hdmi signal output termi- nal6CH1 Audio in terminal RCA 7CH2 Audio in terminal RCACDC power cord clamp BDC power input terminalDSIGNAL GND terminal AIEEE1394 IEEE1394 terminal 6PFREMOTE RS-422A terminal D-SUB 9P ESERIAL Remote terminal mini jackGFan HSlot cover for servicingON-SCREEN Display „ HDV format „ DV formatSampling frequency/audio Output CHDate/time When the unit is in the Analog/HDV Signal RecordingIt displays the date and time Hrmmss Or Stop mode, it displays the data of the built-in clockCounter display VCR operation modeRemaining tape Display displayed during operation Description Event/Alarm displayDisplay displayed for about 3 seconds Description Display DescriptionLP Tape Invalid TapeNo HDV/DV SIG NAL Copy InhibitConnection „ Input signal„ Output signal Audio in terminal RCA×2 Connect an audio cable Connecting audio signalsDigital input IEEE1394 terminal 6P Attaching the supplied ferrite core Connecting with Serial Remote terminals „ Operate BR-HD50 with the wired remote controllerTo the DC cord. XPage Inputting analog signal RECORDING/OUTPUT Signal FormatComponent OUT ModelHD signal Input Inputting digital signalHdmi OUT terminal Line OUT terminal HDVVideo HD signal „ Output terminal video/audio signal format during playbackPlayback IEEE1394 Hdmi OUT terminalTurning off the power Turning on the powerPreparation „ Turn off BR-HD50Operation Lock mode Selecting the operating method main unit/remote controller„ Setting the REMOTE/LOCAL switch „ Turning on the Operation Lock modeEjecting the cassette tape Loading the cassette tapeSetting/Displaying date and time Setting date and timeSetting the date and time in the Clock Adjust Menu screen TC/UB/CLOCK 2/2 Menu screenOn-screen status display Selecting date/time display„ Display Menu screen Setting the Menu screen Check settingsSelecting HD signal format Display the System 2/2 Menu screenRecording Setting Menu screens„ Selecting digital input signal Selecting input signal„ Settings for digital video format Settings for digital signal input„ Setting System Menu screen Setting related Menu screen„ Settings for recording the time code Adjusting audio recording level SettingsAdjusting audio recording level „ Increasing the recording level„ Adjusting the CH2 channel „ Adjusting the CH1 channelAudio recording level is fixed to the initial setting value Recording index signals No backup recording „ For using GY-DV5000/DV5100 as the source unitOFF Recording begins on the source unitRemote SEL SER Recording with Serial Remote terminalsRemote 1/2 Menu screen Remote 2/2 Menu screenPlayback Video settingsSettings regarding playback function Audio settingsFast forward/rewind „ STL/F. ADV DV in the System 1/2 Menu screen Frame-advance playbackSpecial playback functions System 1/2 Menu screenSet BR-HD50 to the Playback or the Still mode Slow playback and Search mode„ DV recorded tape playback „ HDV recorded tape playbackBlank search Index search„ In the Stop mode, press the Blank button Search functionRepeat playback „ Repeat Mode in the System 1/2 Menu screenIndex repeat playback If the head is dirty, repeat play- back may not work wellRegistering cue-up points For details on time code setting and recording XPageClearing registered cue-up points Multi cue-upExiting the Multi Cue-up screen Changing cue-up pointsSearching cue-up points 2Press the R or P button again to change the time- codeDisplaying the time code Time CodeDuring DV input Checking the data of time code generatorPresetting the time code „ Set TCG Select to PresetSetting ...TC/UB/CLOCK 1/2 Menu screen Setting is preset to the time code generatorTCG Select Preset Recording from preset dataPreset time code „ Set the TC/UB/CLOCK 1/2 Menu as followsSelect the Recording mode Counter mode display shows either TCR or UBRTCG Select Regen Check the time code of the IEEE1394 terminalPress the Play button to go to the Playback mode Set the Counter switch to TC or UBCounter switch Playing back the time codeControl with the IEEE1394 ter- minal Digital signals Control with RS-422A Analog signalsEdit „ Remote 2/2 Menu screenSetting the menus „ Set BR-HD50 to the Stop or Still modeMenu Screens TOP Menu screenNo settings are selected yet Counter display shows menu code numbers when setting menusSetting Setting on the monitor display is flashingSystem 1/2 menu Structure of the Menu screensSystem Menu screens TOP Menu screen„ System 1/2 Menu screens Long Pause Repeat Mode1MIN 3MIN„ System 2/2 Menu Remote Menu screens REM FF/REW DelayREM Stop SEL PB StartAudio Menu Screen Monitor Video Menu ScreenSelect OUT FormatDown Conv OUT forLetter Test Signal Hdmi ModeUP Conv DVI Color„ TC/UB/CLOCK 1/2 Menu screen TC/UB/CLOCK Menu screens„ TC/UB/CLOCK 2/2 Menu screen AdjustClock Date MM/DD/YYDisplay Menu screen Others „ Alarm display Displayed regardless of the Display mode„ Warning display Displayed regardless of the Display mode After the REMOTE/LOCAL switch Troubleshooting Symptom Action No powerRecorded during DV signal input Unable to recordNo signal is output from No HD signal is output fromHdmi OUT or Component OUT Display on the monitorChecking the hour meter „ Set BR-HD50 to the Stop modeSystem 1/2 Menu screen is displayed Press the Menu button to return to the normal screen„ Accessories „ Connectors„ General „ Video„ External dimensions Unit mm „ AC adapter section Important Safety InstructionsSupplement