JVC BR-HD50E instruction manual Port Cable Length, European Union

Page 4

Supplement

This equipment is in conformity with the provisions and protection requirements of the corresponding European Directives. This equipment is designed for professional video appliances and can be used in the following environments:

„Residential (including both of the location type class 1 and 2 found in IEC 1000-2-5)

„Commercial and light industrial (including, for example, theatres)

„Urban outdoors (based on the definition of location type class 6 in IEC 1000-2-5)

In order to keep the best performance and furthermore for electromagnetic compatibility we recom- mend to use cables not exceeding the following lengths:

Port

Cable

Length

 

 

 

AUDIO

SHIELDED CABLE

10 meters

 

 

 

LINE

COAXIAL CABLE

10 meters

 

 

 

COMPONENT

COAXIAL CABLE

10 meters

 

 

 

Y/C

COAXIAL CABLE

10 meters

 

 

 

IEEE1394

SHIELDED TWIST PAIR CABLE

4.5 meters

 

 

 

HDMI

SHIELDED TWIST PAIR CABLE

5 meters

 

 

 

REMOTE

SHIELDED TWIST PAIR CABLE

5 meters

 

 

 

The inrush current of this apparatus is 9.0 amperes.

Caution:

„Where there are strong electromagnetic waves or magnetism, for example near a radio or TV trans- mitter, transformer, motor, etc., the picture and sound may be disturbed. In such a case, please keep the apparatus away from the sources of the disturbance.

Information for Users on Disposal of Old Equipment

Attention: This symbol is only valid in the European Union.

[European Union]

This symbol indicates that the electrical and electronic equipment should not be dis- posed as general household waste at its end-of-life. Instead, the product should be handed over to the applicable collection point for the recycling of electrical and elec- tronic equipment for proper treatment, recovery and recycling in accordance with your national legislation.

By disposing of this product correctly, you will help to conserve natural resources and will help prevent potential negative effects on the environment and human health which could otherwise be caused by inappropriate waste handling of this product. For more information about collection point and recycling of this product, please con- tact your local municipal office, your household waste disposal service or the shop where you purchased the product.

Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

(Business users)

If you wish to dispose of this product, please visit our web page www.jvc-europe.com to obtain information about the take-back of the product.

[Other Countries outside the European Union]

If you wish to dispose of this product, please do so in accordance with applicable national legislation or other rules in your country for the treatment of old electrical and electronic equipment.

III

Image 4
Contents BR-HD50 For Customer UseImportant Safeguards Remarque InformationInformation for Canada Renseignement Pour Canada European Union Port Cable LengthBusiness users Other Countries outside the European Union Power System For Your Safety Please Read the Following Text CarefullyMust be Earthed For Continental EUROPE, ETC For U.K. onlyCompatible with 60Hz/50Hz HD signal for- mat HDV 720p formatCompatible with DV format Compatible mechanism for standard/mini DV cassettesTable of Contents Introduction Remarks of usageCassette tape „ Erasure preventionStandard DV cas- z Mini DV cassettes settes LA-DV276M-DV63PRO LA-DV186M-DV63HD LA-DV124„ HD signal format „ HDV and DV signal input/outputHDV and DV format „ Recording time „ HDV 720p and DV format„ HD video output „ Regular maintenance Regular maintenance„ Head cleaning Cleaning tape CondensationOperating environ MentNames and Functions of Parts 1Cassette loading slot/LED2OPERATE button/LED 3EJECT button„ Play button/LED „ Pause button/LED„ FF button/LED „ Stop button/LED5REMOTE/LOCAL switch 6INPUT Select switch 7COUNTER switch8IEEE1394 IEEE1394 terminal switch „ Dvcam indicator light„ 60 indicator light „ 50 indicator lightFRESET button HSpecial functions/Setting buttonsSetting screens EMENU button„ BLANK/P button „ SEARCH+/S button„ SEARCH-/Q button „ SET button3VIDEO Line OUT terminal BNC 2VIDEO Y/C in terminal 4-PINRear panel 0HDMI OUT Hdmi signal output termi- nal 5COMPONENT OUT Component sig- nal output terminal BNC×36CH1 Audio in terminal RCA 7CH2 Audio in terminal RCABDC power input terminal CDC power cord clampDSIGNAL GND terminal AIEEE1394 IEEE1394 terminal 6PESERIAL Remote terminal mini jack FREMOTE RS-422A terminal D-SUB 9PGFan HSlot cover for servicingON-SCREEN Display „ DV format „ HDV formatSampling frequency/audio Output CHWhen the unit is in the Analog/HDV Signal Recording Date/timeIt displays the date and time Hrmmss Or Stop mode, it displays the data of the built-in clockCounter display VCR operation modeRemaining tape Event/Alarm display Display displayed during operation DescriptionDisplay displayed for about 3 seconds Description Display DescriptionInvalid Tape LP TapeNo HDV/DV SIG NAL Copy Inhibit„ Input signal Connection„ Output signal Audio in terminal RCA×2 Connect an audio cable Connecting audio signalsDigital input IEEE1394 terminal 6P Attaching the supplied ferrite core „ Operate BR-HD50 with the wired remote controller Connecting with Serial Remote terminalsTo the DC cord. XPage RECORDING/OUTPUT Signal Format Inputting analog signalComponent OUT ModelInputting digital signal HD signal InputHdmi OUT terminal Line OUT terminal HDV„ Output terminal video/audio signal format during playback Video HD signalPlayback IEEE1394 Hdmi OUT terminalTurning on the power Turning off the powerPreparation „ Turn off BR-HD50Selecting the operating method main unit/remote controller Operation Lock mode„ Setting the REMOTE/LOCAL switch „ Turning on the Operation Lock modeLoading the cassette tape Ejecting the cassette tapeSetting date and time Setting/Displaying date and timeSetting the date and time in the Clock Adjust Menu screen TC/UB/CLOCK 2/2 Menu screenOn-screen status display Selecting date/time display„ Display Menu screen Check settings Setting the Menu screenSelecting HD signal format Display the System 2/2 Menu screenSetting Menu screens RecordingSelecting input signal „ Selecting digital input signal„ Settings for digital video format Settings for digital signal input„ Setting System Menu screen Setting related Menu screen„ Settings for recording the time code Settings Adjusting audio recording levelAdjusting audio recording level „ Increasing the recording level„ Adjusting the CH2 channel „ Adjusting the CH1 channelAudio recording level is fixed to the initial setting value Recording index signals „ For using GY-DV5000/DV5100 as the source unit No backup recordingOFF Recording begins on the source unitRecording with Serial Remote terminals Remote SEL SERRemote 1/2 Menu screen Remote 2/2 Menu screenVideo settings PlaybackAudio settings Settings regarding playback functionFast forward/rewind Frame-advance playback „ STL/F. ADV DV in the System 1/2 Menu screenSpecial playback functions System 1/2 Menu screenSlow playback and Search mode Set BR-HD50 to the Playback or the Still mode„ DV recorded tape playback „ HDV recorded tape playbackIndex search Blank search„ In the Stop mode, press the Blank button Search function„ Repeat Mode in the System 1/2 Menu screen Repeat playbackIndex repeat playback If the head is dirty, repeat play- back may not work wellFor details on time code setting and recording XPage Registering cue-up pointsClearing registered cue-up points Multi cue-upChanging cue-up points Exiting the Multi Cue-up screenSearching cue-up points 2Press the R or P button again to change the time- codeTime Code Displaying the time codeDuring DV input Checking the data of time code generator„ Set TCG Select to Preset Presetting the time codeSetting ...TC/UB/CLOCK 1/2 Menu screen Setting is preset to the time code generatorRecording from preset data TCG Select PresetPreset time code „ Set the TC/UB/CLOCK 1/2 Menu as followsCounter mode display shows either TCR or UBR Select the Recording modeTCG Select Regen Check the time code of the IEEE1394 terminalSet the Counter switch to TC or UB Press the Play button to go to the Playback modeCounter switch Playing back the time codeControl with RS-422A Analog signals Control with the IEEE1394 ter- minal Digital signalsEdit „ Remote 2/2 Menu screen„ Set BR-HD50 to the Stop or Still mode Setting the menusMenu Screens TOP Menu screenCounter display shows menu code numbers when setting menus No settings are selected yetSetting Setting on the monitor display is flashingStructure of the Menu screens System 1/2 menuSystem Menu screens TOP Menu screen„ System 1/2 Menu screens Repeat Mode Long Pause1MIN 3MIN„ System 2/2 Menu Remote Menu screens Delay REM FF/REWREM Stop SEL PB StartAudio Menu Screen Video Menu Screen MonitorSelect OUT FormatDown Conv OUT forLetter Hdmi Mode Test SignalUP Conv DVI ColorTC/UB/CLOCK Menu screens „ TC/UB/CLOCK 1/2 Menu screenAdjust „ TC/UB/CLOCK 2/2 Menu screenClock Date MM/DD/YYDisplay Menu screen „ Alarm display Displayed regardless of the Display mode Others„ Warning display Displayed regardless of the Display mode Troubleshooting Symptom Action No power After the REMOTE/LOCAL switchRecorded during DV signal input Unable to recordNo HD signal is output from No signal is output fromHdmi OUT or Component OUT Display on the monitor„ Set BR-HD50 to the Stop mode Checking the hour meterSystem 1/2 Menu screen is displayed Press the Menu button to return to the normal screen„ Connectors „ Accessories„ General „ Video„ External dimensions Unit mm „ AC adapter section Important Safety InstructionsSupplement