JVC TK-C655 manual Attach the cover, Coaxial cable, Control signal cables

Page 15

Coaxial cable

Connecting a RG-59coaxial cable.

If a RG-11coaxial cable is used it cannot be con- nected directly to the terminal board. To use such a cable, connect a RG-59cable to the camera and then connect the RG-11cable to the RG-59cable.

Trim the end of the coaxial cable as shown below before connecting it.

Fold back the mesh wires and secure them with insulation tape in order to prevent them from becoming loose and thus causing a short circuit.

Polyethylene

Mesh wires

Conductor

 

wire

 

7

17

(5)

(12)

 

Insulation tape

The figures inside the brackets ( ) are the dimensions

when the coaxial cable is distributed from the side of the cover. (Unit : mm)

If the cable is extended, the signal attenuation is increased, the resolution drops and the noise increases. Should it be required to extend the cable, use a thicker cable or a ca- ble length compensator.

To feed the coaxial cable through the cap on the side of the cover, change the positioning of the cable plate as shown below.

 

Provided screw

 

Screw removed in the

Provided cable

figure on the left

plate

 

Control signal cables

The RM-P2580 unit allows the connection of up to eight cam- eras to the one set of control signal cables. The overall maxi- mum permissible length of these control signal cables is 1200 metres.

Cable

Flat-blade

screwdriver

The connector can be released by

loosening the screws on the two sides as shown in the figure.

Flat-blade screwdriver

Strip the coating of each cable by about 4

mmbefore inserting it. After connecting all of the cables, turn the screws on the side to fasten the connectors.

It is recommended to use a 4-core (a pair) twisted pair cable (0.65) or a twisted pair cable of category 3 or higher which is used for Ethernet.

Cables with a thickness between 16 AWG and 26 AWG can be used. Connect the control signal cables so that the TX+ and TX- signals form a pair and the RX+ and RX- signals form another pair.

5. Attach the cover.

Attach the cover to the Ceiling Mount by reversing the operations in step 2.

15

Image 15
Contents TK-C655 Important Safeguards Contents Features Provided AccessoriesSafety Precautions  Zooming Precautions for Correct Operation Preset positions Camera setups with which auto focusing may be difficult Ceiling Mount Controls, Connectors and Indicators Ceiling Mount  Camera Switch settings P Multi-Drop Communication SystemCable connections P Memo Point-to-Point Communication System Turn all the components power off before proceedingConnector side of the Ceiling Mount Switch 7 OFF Switch 8 onFor example connection with an RM-P2580 Four wires must be connectedTwo wires must be connected Duplex Setting switches Switch SettingsExample Camera ID check procedureMachine ID Bers on the RM-P2580Pass the cables through the cover Cable ConnectionsMake a 90 mm diameter hole in the ceiling Remove the cover from the Ceiling MountControl signal cables Attach the coverCoaxial cable Attaching the Camera Attaching a safety wireAttach the drop prevention wire Attaching the Ceiling MountRotate the camera Tighten the lock screw using a Phillips screwdriverEnsure that the locking screw is loose Fit the cameraPress the SET button Setup ProcedureSetting the camera menus from an RM-P2580 Press and hold the Menu button for 3 secondsNormal screen Menu Screen FlowCamera Function Screen Camera TITLE/ALARM Screen Camera ALC/ExDR screen Camera Video Adjustment ScreenSense UP AGC ModePosition Function SET Screen Auto PAN/PATROL/TRACE ScreenFactory Settings screen Private Mask Setup Camera Title Setup Press the Tele buttonRepeat steps 5 and 6 for each title character Repeat steps 5 to 7 for each area title Area Title SetupMove the cursor to Area Title Edit and press the SET button Press the FAR buttonAlarm Title Setup Display the Setup menu on the cameraRepeat steps 5 to 7 for each alarm title Auto PAN Setup Set the auto pan mode and speedAdjust the viewing angle of the start position Auto Patrol Setup Auto Trace SET screen is displayed Auto Trace SetupMove the cursor to Autotrace SET and press the SET button Set the patrol start positionPosition Title screen Position Title SetupRepeat steps 5 to 7 for each title character Position Function SET screenCeiling plate Attaching a Flush Mounted Ceiling Bracket Optional WB-S575Clamp the Flush Mounted Ceiling Bracket IngConnection Cables Attach the ceiling panelCheck the release labels thoroughly before removal Removing a Flush Mounted Ceiling Bracket Optional WB-S575Remove the ceiling panel Remove the cameraSymptom Cause Information Remedy TroubleshootingGeneral SpecificationsCamera Pan/Tilt MechanismWB-S575 Flush Mounted Ceiling Bracket + Ceiling panel External dimensions Unit mmDimensions in combination with the WB-S575 Ceiling Mount holeTK-C655 Dome Type Camera