JVC TK-C655 manual Alarm Title Setup, Display the Setup menu on the camera

Page 29

ALARM TITLE Setup

This unit is not equipped with alarm input/output.

This function sets up the alarm title to be displayed when an alarm signal is input to the RM-P2580 remote control unit. Up to 10 alarm titles (ALARM TITLE 1 to 10) can be set and each title can be up to 12 characters in length.

MENU button

SET button

 

 

 

REMOTE CONTROL UNIT RM-P2580

SETUP

 

CAMERA

POSITION

 

 

 

 

POWER

 

 

 

 

MENU

SET

ALARM

AUTO

F-1

F-2

F-3

 

 

KEY LOCK

 

 

 

 

CAMERA

 

LENS

 

 

CAMERA/POSITION

PAN/TILT

buttons

 

SPEED

 

1

2

3

CAMERA

POSI-

 

 

 

 

 

 

 

TION

 

 

IRIS

 

4

5

6

1

2

 

CLOSE

OPEN

 

 

 

OPTION

OPTION

PAN/TILT

NEAR

FOCUS

FAR

7

8

9

AUTO

AUTO

 

AF

 

PAN

PATROL

lever

WIDE

ZOOM

TELE

CLEAR

0

ENTER

 

 

 

 

 

 

/HOME

 

 

 

 

 

 

 

ENTER button

 

 

FAR button

 

 

TELE button

 

 

WIDE button

 

 

 

 

 

 

 

 

NEAR button

 

 

 

 

 

 

 

 

– – – M E N U – – –

 

C A M . F U N C T I O N . .

 

 

C A M . T I T L E / A L A R M . .

 

C A M . V I D E O A D J U S T . .

 

C A M . A L C / E x D R . .

 

 

A U T O P A N / P A T R O L / T R A C E . .

 

P O S I . F U N C T I O N S E T . .

 

F A C T O R Y S E T T I N G S . .

 

SETUP menu on camera

– – – C A M E R A T I T L E / A L A R M – – –

C A M . T I T L E E D I T . .

 

A R E A T I T L E

O F F

A R E A T I T L E E D I T . .

 

A L M . T I T L E

S I Z E

D O U B L E

A L M . T I T L E

C O L O U R

W H I T E

A L A R M T I T L E E D I T . .

1. Select the camera. ( RM-P2580 Instruction manual)

CAMERA button Numeric key (camera number) ENTER but- ton.

The picture of the selected camera is output.

2. Display the SETUP menu on the camera.

( P. 18, steps 1 to 4 )

MENU button (3 sec.) Select “CAMERA” with the PAN/TILT lever

SET button.

The camera moves to the home position.

3. Tilt the PAN/TILT lever up or down to move the cur- sor (>) to “CAMERA TITLE/ALARM” and press the SET button.

The TITLE/ALARM screen is displayed.

4. Move the cursor (>) onto the item “ALARM TITLE EDIT” and press the SET button.

The ALARM TITLE 1 menu is displayed.

The first few characters in the character area and title input field blink to indicate that the system is ready for a title input.

5.Tilt the PAN/TILT lever to select the first character of the title from the character area.

The character being selected blinks.

The selected character is displayed in the title input field.

6.Press the TELE button.

The first character of the title is input, and the system gets ready for the input of the second character.

If the WIDE button is pressed, the blinking position in the title in- put field moves to the left. Use this facility to correct previously input characters.

 

 

TITLE/ALARM menu

7.

 

 

 

 

 

 

 

Space Blinking

Character area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– – – A L A R M T I T L E 1 – – –

 

 

 

0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K

 

8.

 

 

 

 

L M N O P

Q

R S T U V W X Y Z a b c d e f g

 

 

h i j k l m n o p q r s t u v w x y z . , '

 

 

– : / Ä Ö Ü Â Ê Î Ô Û Ç Ñ ä ë ï ö ü â ê î ô

 

 

 

û á é í ó ú à è ì ò ù ç ñ ß ¡ ¿

 

 

W I D E

T E L E ￿

Title input

9.

T I T L E N O . S E L E C T F O C U S

field

 

 

 

 

Blinking

 

 

 

Press the FAR button.

The next ALARM TITLE screen is displayed.

If the NEAR button is pressed, the previous ALARM TITLE screen is displayed.

Repeat steps 5 to 7 for each alarm title.

Complete the input of all the alarm titles (ALARM TITLE 1 to 10) in this way.

Press the MENU button.

• The screen returns to the previous menu.

ALARM TITLE screen

RM-P2580 units need to be configured to display Alarm Titles. Use the RM-P2580 menu settings to do this:

1.Press and hold the MENU button for 3 seconds to display the SETUP screen on the remote control unit.

2.First select the CONTROL UNIT screen, then the DATA I/O screen and finally the INPUT ASSIGNMENT screen.

3.Select “ALARM TEXT” then “EDIT 1”, the alarm title set as ALARM TITLE 1 is displayed on the monitor.

*The alarm signals are input into the DATA I/O terminals on the rear panel of the RM-P2580.

29

Image 29
Contents TK-C655 Important Safeguards Contents Safety Precautions FeaturesProvided Accessories  Preset positions Precautions for Correct OperationCamera setups with which auto focusing may be difficult  Zooming Ceiling Mount Controls, Connectors and Indicators Ceiling Mount  Camera Cable connections P Switch settings PMulti-Drop Communication System Memo Connector side of the Ceiling Mount Turn all the components power off before proceedingSwitch 7 OFF Switch 8 on Point-to-Point Communication SystemTwo wires must be connected Four wires must be connectedDuplex For example connection with an RM-P2580 Setting switches Switch SettingsMachine ID Camera ID check procedureBers on the RM-P2580 ExampleMake a 90 mm diameter hole in the ceiling Cable ConnectionsRemove the cover from the Ceiling Mount Pass the cables through the coverCoaxial cable Control signal cablesAttach the cover Attach the drop prevention wire Attaching a safety wireAttaching the Ceiling Mount Attaching the CameraEnsure that the locking screw is loose Tighten the lock screw using a Phillips screwdriverFit the camera Rotate the cameraSetting the camera menus from an RM-P2580 Setup ProcedurePress and hold the Menu button for 3 seconds Press the SET buttonNormal screen Menu Screen FlowCamera Function Screen Camera TITLE/ALARM Screen Camera ALC/ExDR screen Camera Video Adjustment ScreenSense UP AGC ModePosition Function SET Screen Auto PAN/PATROL/TRACE ScreenFactory Settings screen Private Mask Setup Repeat steps 5 and 6 for each title character Camera Title SetupPress the Tele button Move the cursor to Area Title Edit and press the SET button Area Title SetupPress the FAR button Repeat steps 5 to 7 for each area titleRepeat steps 5 to 7 for each alarm title Alarm Title SetupDisplay the Setup menu on the camera Adjust the viewing angle of the start position Auto PAN SetupSet the auto pan mode and speed Auto Patrol Setup Move the cursor to Autotrace SET and press the SET button Auto Trace SetupSet the patrol start position Auto Trace SET screen is displayedRepeat steps 5 to 7 for each title character Position Title SetupPosition Function SET screen Position Title screenClamp the Flush Mounted Ceiling Bracket Attaching a Flush Mounted Ceiling Bracket Optional WB-S575Ing Ceiling plateConnection Cables Attach the ceiling panelRemove the ceiling panel Removing a Flush Mounted Ceiling Bracket Optional WB-S575Remove the camera Check the release labels thoroughly before removalSymptom Cause Information Remedy TroubleshootingCamera SpecificationsPan/Tilt Mechanism GeneralDimensions in combination with the WB-S575 External dimensions Unit mmCeiling Mount hole WB-S575 Flush Mounted Ceiling Bracket + Ceiling panelTK-C655 Dome Type Camera