JVC TK-C655 manual Camera Function Screen

Page 20

Setting Up the Camera Using an RM-P2580

CAMERA FUNCTION Screen

This screen sets up the functions of the camera itself.

Item

 

 

 

 

 

Function & Setting

Initial Value

 

 

 

 

 

 

 

 

V. PHASE

This adjusts the vertical synchronization to those of other cameras when a selector

0

 

switch for the synchronizing system on the Ceilling Mount is at LL. (50 Hz power

 

 

region only.)

 

 

Setting values : –156 to 0 to 156

 

 

 

 

 

 

 

 

 

POS.TITLE LOC.

Sets the location of the position title and area title in the monitor.

UP-L

 

UP

: At the top of the screen.

 

 

DOWN

: At the bottom of the screen.

 

 

L

: In the left half of the screen.

 

 

C

: In the centre of the screen.

 

 

R

: In the right half of the screen

 

 

Setting values : UP-L, UP-C, UP-R, DOWN-L, DOWN-C, DOWN-R

 

 

 

 

 

 

 

 

 

FLIP

When a tilting operation is started while this item is OFF, the camera will stop at the

DIGITAL

 

position where it is pointing straight downwards. When an object moves directly

 

 

below the camera, the camera makes three movements 1points the straight down-

 

 

wards 2 pans 180° 3 points upwards.

 

 

The FLIP function makes it possible to reduce these operations. Use this function

 

 

when monitoring an object passing directly below the camera.

 

 

OFF

: Turns the FLIP function off.

 

 

DIGITAL : Once the camera reaches a tilt of 135˚ from horizontal after passing a

 

 

 

 

 

position facing directly downwards, a picture is inverted both vertically

 

 

AUTO

and horizontally.

 

 

: When the camera reaches a position facing directly downwards, it pans

 

 

 

 

 

by 180° then stops.

 

 

 

 

 

 

 

 

 

VAR. P/T SPEED

Under this function, the panning and tilting speeds are adjusted automatically rela-

ON

 

tive to the zoom ratio of the lens. Setting the zoom lens towards TELE decreases

 

 

the pan and tilting speeds.

 

 

Setting the zoom lens towards WIDE end increases the pan and tilting speeds.

 

 

Use this function when monitoring objects at differing zoom ratios.

 

 

OFF : Turns this function off.

 

 

ON : Turns this function on.

 

 

 

 

 

 

 

 

 

EASY AF

When this item is set to ON, the auto focusing (AF) is activated automatically dur-

OFF

 

ing manual pan/tilt and zoom operations.

 

 

This function is convenient when frequent manual operations are expected as it

 

 

eliminates the need to focus manually after every manual operation.

 

 

OFF : Turns this function off.

 

 

ON : Turns this function on.

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

Auto focusing may sometimes be incapable of bringing certain objects into accurate focus.

 

 

 

(P. 5)

 

 

 

In this case, use the manual focusing facility.

 

 

 

 

 

 

 

 

 

V.SHARPNESS

This function sets sharpness in the vertical direction of the image.

NORMAL

 

NORMAL : Normal sharpness.

 

 

HIGH

: High sharpness.

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

The following phenomena may be observed when HIGH is selected. This is not a malfunc-

 

 

 

tion.

 

 

 

 

 

 

 

• Horizontal stripes are observed on bright objects.

 

 

 

• Vague horizontal stripes are observed under low light conditions.

 

 

 

 

 

 

 

 

 

PRIVATE MASK..

This function grays out sections that are not to be displayed in the monitored pic-

 

ture area.

 

 

The grayed out section moves accordingly when the camera is panned, tilted or

 

 

when the zoom is adjusted.

 

 

P.26, “PRIVATE MASK Setup”

 

20

Image 20
Contents TK-C655 Important Safeguards Contents Safety Precautions FeaturesProvided Accessories Precautions for Correct Operation  Preset positionsCamera setups with which auto focusing may be difficult  ZoomingControls, Connectors and Indicators  Ceiling Mount Ceiling Mount  Camera Cable connections P Switch settings PMulti-Drop Communication System Memo Turn all the components power off before proceeding Connector side of the Ceiling MountSwitch 7 OFF Switch 8 on Point-to-Point Communication SystemFour wires must be connected Two wires must be connectedDuplex For example connection with an RM-P2580Switch Settings  Setting switchesCamera ID check procedure Machine IDBers on the RM-P2580 ExampleCable Connections Make a 90 mm diameter hole in the ceilingRemove the cover from the Ceiling Mount Pass the cables through the coverCoaxial cable Control signal cablesAttach the cover Attaching a safety wire Attach the drop prevention wireAttaching the Ceiling Mount Attaching the CameraTighten the lock screw using a Phillips screwdriver Ensure that the locking screw is looseFit the camera Rotate the cameraSetup Procedure Setting the camera menus from an RM-P2580Press and hold the Menu button for 3 seconds Press the SET buttonMenu Screen Flow Normal screenCamera Function Screen Camera TITLE/ALARM Screen Camera Video Adjustment Screen Camera ALC/ExDR screenAGC Mode Sense UPAuto PAN/PATROL/TRACE Screen Position Function SET ScreenFactory Settings screen Private Mask Setup Repeat steps 5 and 6 for each title character Camera Title SetupPress the Tele button Area Title Setup Move the cursor to Area Title Edit and press the SET buttonPress the FAR button Repeat steps 5 to 7 for each area titleRepeat steps 5 to 7 for each alarm title Alarm Title SetupDisplay the Setup menu on the camera Adjust the viewing angle of the start position Auto PAN SetupSet the auto pan mode and speed Auto Patrol Setup Auto Trace Setup Move the cursor to Autotrace SET and press the SET buttonSet the patrol start position Auto Trace SET screen is displayedPosition Title Setup Repeat steps 5 to 7 for each title characterPosition Function SET screen Position Title screenAttaching a Flush Mounted Ceiling Bracket Optional WB-S575 Clamp the Flush Mounted Ceiling BracketIng Ceiling plateAttach the ceiling panel Connection CablesRemoving a Flush Mounted Ceiling Bracket Optional WB-S575 Remove the ceiling panelRemove the camera Check the release labels thoroughly before removalTroubleshooting Symptom Cause Information RemedySpecifications CameraPan/Tilt Mechanism GeneralExternal dimensions Unit mm Dimensions in combination with the WB-S575Ceiling Mount hole WB-S575 Flush Mounted Ceiling Bracket + Ceiling panelTK-C655 Dome Type Camera