JVC TK-C655 manual  Ceiling Mount  Camera

Page 7

 Ceiling Mount

 Camera

&

^

# % $

! #

@

(Setting switch side)

)

 

*

(

!Camera Connector (Female)

Connect to ^, the Male Connector on the camera.

@Drop Prevention Hook

Attach the Drop Prevention Wire & to this hook to prevent the camera from falling.

#Clamping Holes (x 4)

Attach the camera to a ceiling or to a Flush Mounted Ceil- ing Bracket (optionally available) using these holes.

$[MACHINE ID] Switch

When an RS-485 communication system is used, for ex- ample when using the camera in a system controlled by an RM-P2580, set the camera IDs individually for each

camera. P. 13

%Setting Switches

Use these to set the PROTOCOL, etc. P. 12

^Connector (Male)

Connect to !, the Female Camera Connector on the Ceiling Mount.

&Drop Prevention Wire

Attach this wire to the Drop Prevention Hook @ on the Ceiling Mount.

*Camera Clamping Bracket

In order to clamp the camera onto the Ceiling Mount, in- sert and tighten the Locking Screw 4 into this bracket.

(Lens

The lens is not a replaceable item.

)Dome Cover

The dome cover is fragile. Take care when handling it.

Camera Body Cover

Do not remove the camera body cover while the camera is installed on a ceiling. Doing so will cause the dome cover to fall down.

7

Image 7
Contents TK-C655 Important Safeguards Contents Provided Accessories FeaturesSafety Precautions  Zooming Precautions for Correct Operation Preset positions Camera setups with which auto focusing may be difficult Ceiling Mount Controls, Connectors and Indicators Ceiling Mount  Camera Multi-Drop Communication System Switch settings PCable connections P Memo Point-to-Point Communication System Turn all the components power off before proceedingConnector side of the Ceiling Mount Switch 7 OFF Switch 8 onFor example connection with an RM-P2580 Four wires must be connectedTwo wires must be connected Duplex Setting switches Switch SettingsExample Camera ID check procedureMachine ID Bers on the RM-P2580Pass the cables through the cover Cable ConnectionsMake a 90 mm diameter hole in the ceiling Remove the cover from the Ceiling MountAttach the cover Control signal cablesCoaxial cable Attaching the Camera Attaching a safety wireAttach the drop prevention wire Attaching the Ceiling MountRotate the camera Tighten the lock screw using a Phillips screwdriverEnsure that the locking screw is loose Fit the cameraPress the SET button Setup ProcedureSetting the camera menus from an RM-P2580 Press and hold the Menu button for 3 secondsNormal screen Menu Screen FlowCamera Function Screen Camera TITLE/ALARM Screen Camera ALC/ExDR screen Camera Video Adjustment ScreenSense UP AGC ModePosition Function SET Screen Auto PAN/PATROL/TRACE ScreenFactory Settings screen Private Mask Setup Press the Tele button Camera Title SetupRepeat steps 5 and 6 for each title character Repeat steps 5 to 7 for each area title Area Title SetupMove the cursor to Area Title Edit and press the SET button Press the FAR buttonDisplay the Setup menu on the camera Alarm Title SetupRepeat steps 5 to 7 for each alarm title Set the auto pan mode and speed Auto PAN SetupAdjust the viewing angle of the start position Auto Patrol Setup Auto Trace SET screen is displayed Auto Trace SetupMove the cursor to Autotrace SET and press the SET button Set the patrol start positionPosition Title screen Position Title SetupRepeat steps 5 to 7 for each title character Position Function SET screenCeiling plate Attaching a Flush Mounted Ceiling Bracket Optional WB-S575Clamp the Flush Mounted Ceiling Bracket IngConnection Cables Attach the ceiling panelCheck the release labels thoroughly before removal Removing a Flush Mounted Ceiling Bracket Optional WB-S575Remove the ceiling panel Remove the cameraSymptom Cause Information Remedy TroubleshootingGeneral SpecificationsCamera Pan/Tilt MechanismWB-S575 Flush Mounted Ceiling Bracket + Ceiling panel External dimensions Unit mmDimensions in combination with the WB-S575 Ceiling Mount holeTK-C655 Dome Type Camera