A system that does not employ the
MEMO
Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of
●When the controller is located in the middle of the system cable. (An AC 24V power source must be supplied to each camera)
CAM1
| CONTROL Cable |
CAM2 Length of stub | CAM31 Length of stub CAM32 |
| Length of stub |
PROTOCOL(1) | : ON |
MACHINE ID | : 01 |
RX TERM | : ON |
PROTOCOL(1) | : ON |
MACHINE ID | : 02 |
RX TERM | : OFF |
CONTROLLER*
PROTOCOL(1) | : ON |
MACHINE ID | : 31 |
RX TERM | : OFF |
PROTOCOL(1) | : ON |
MACHINE ID | : 32 |
RX TERM | : ON |
•Set the TERM switches of the cameras at each end (CAM1 and CAM32) to ON, and the TERM switches of the other cameras to OFF.
•Do not terminate at the controller.
VIDEO SWITCHER, etc.
●When the controller is located at the end of the system cable. (An AC 24V power source must be supplied to each camera)
CONTROL Cable
CAM1
PROTOCOL(1) | : ON |
MACHINE ID | : 01 |
RX TERM | : ON |
CAM2 Length of stub | CAM32 | Length of stub | Terminate it | |
with 110 Ω. | ||||
|
|
|
|
|
| CONTROLLER* |
PROTOCOL(1) : ON | PROTOCOL(1) : ON | ||
MACHINE ID | : 02 | MACHINE ID | : 32 |
RX TERM | : OFF | RX TERM | : OFF |
•Set the TERM switch of CAM1 to ON, and terminate at the controller with a resistance of 110 Ω.
Set the TERM switches of the other cameras to OFF.
VIDEO SWITCHER, etc.
9