A system that does not employ the RM-P2580 as the controller

MEMO

Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of non-terminated equipment (cameras or controllers) must be as short as possible. If the length of stub is too long, the precision of the control may suffer.

When the controller is located in the middle of the system cable. (An AC 24V power source must be supplied to each camera)

CAM1

 

CONTROL Cable

CAM2 Length of stub

CAM31 Length of stub CAM32

 

Length of stub

PROTOCOL(1)

: ON

MACHINE ID

: 01

RX TERM

: ON

PROTOCOL(1)

: ON

MACHINE ID

: 02

RX TERM

: OFF

CONTROLLER*

PROTOCOL(1)

: ON

MACHINE ID

: 31

RX TERM

: OFF

PROTOCOL(1)

: ON

MACHINE ID

: 32

RX TERM

: ON

Set the TERM switches of the cameras at each end (CAM1 and CAM32) to ON, and the TERM switches of the other cameras to OFF.

Do not terminate at the controller.

VIDEO SWITCHER, etc.

When the controller is located at the end of the system cable. (An AC 24V power source must be supplied to each camera)

CONTROL Cable

CAM1

PROTOCOL(1)

: ON

MACHINE ID

: 01

RX TERM

: ON

CAM2 Length of stub

CAM32

Length of stub

Terminate it

with 110 Ω.

 

 

 

 

 

 

CONTROLLER*

PROTOCOL(1) : ON

PROTOCOL(1) : ON

MACHINE ID

: 02

MACHINE ID

: 32

RX TERM

: OFF

RX TERM

: OFF

Set the TERM switch of CAM1 to ON, and terminate at the controller with a resistance of 110 .

Set the TERM switches of the other cameras to OFF.

VIDEO SWITCHER, etc.

9

Image 9
Contents TK-C655 Important Safeguards Contents Features Provided AccessoriesSafety Precautions  Preset positions Precautions for Correct OperationCamera setups with which auto focusing may be difficult  Zooming Ceiling Mount Controls, Connectors and Indicators Ceiling Mount  Camera Switch settings P Multi-Drop Communication SystemCable connections P Memo Connector side of the Ceiling Mount Turn all the components power off before proceedingSwitch 7 OFF Switch 8 on Point-to-Point Communication SystemTwo wires must be connected Four wires must be connectedDuplex For example connection with an RM-P2580 Setting switches Switch SettingsMachine ID Camera ID check procedureBers on the RM-P2580 ExampleMake a 90 mm diameter hole in the ceiling Cable ConnectionsRemove the cover from the Ceiling Mount Pass the cables through the coverControl signal cables Attach the coverCoaxial cable Attach the drop prevention wire Attaching a safety wireAttaching the Ceiling Mount Attaching the CameraEnsure that the locking screw is loose Tighten the lock screw using a Phillips screwdriverFit the camera Rotate the cameraSetting the camera menus from an RM-P2580 Setup ProcedurePress and hold the Menu button for 3 seconds Press the SET buttonNormal screen Menu Screen FlowCamera Function Screen Camera TITLE/ALARM Screen Camera ALC/ExDR screen Camera Video Adjustment ScreenSense UP AGC ModePosition Function SET Screen Auto PAN/PATROL/TRACE ScreenFactory Settings screen Private Mask Setup Camera Title Setup Press the Tele buttonRepeat steps 5 and 6 for each title character Move the cursor to Area Title Edit and press the SET button Area Title SetupPress the FAR button Repeat steps 5 to 7 for each area titleAlarm Title Setup Display the Setup menu on the cameraRepeat steps 5 to 7 for each alarm title Auto PAN Setup Set the auto pan mode and speedAdjust the viewing angle of the start position Auto Patrol Setup Move the cursor to Autotrace SET and press the SET button Auto Trace SetupSet the patrol start position Auto Trace SET screen is displayedRepeat steps 5 to 7 for each title character Position Title SetupPosition Function SET screen Position Title screenClamp the Flush Mounted Ceiling Bracket Attaching a Flush Mounted Ceiling Bracket Optional WB-S575Ing Ceiling plateConnection Cables Attach the ceiling panelRemove the ceiling panel Removing a Flush Mounted Ceiling Bracket Optional WB-S575Remove the camera Check the release labels thoroughly before removalSymptom Cause Information Remedy TroubleshootingCamera SpecificationsPan/Tilt Mechanism GeneralDimensions in combination with the WB-S575 External dimensions Unit mmCeiling Mount hole WB-S575 Flush Mounted Ceiling Bracket + Ceiling panelTK-C655 Dome Type Camera