Panasonic WV-NM100 operating instructions Bootp

Page 28

SETUP

Network speed

Common to all connection

Set the network speed.

 

types

Use the default setting “auto” for the network speed.

 

 

Selectable parameters: auto (default setting), 100 Mbps (full

 

 

duplex), 100 Mbps (half duplex), 10 Mbps (full duplex), 10 Mbps

 

 

(half duplex)

 

 

 

HTTP port

Connection type 1, 2 and 3

Use the default setting “80” for the HTTP port.

 

 

 

 

Connection type 4

If multiple cameras are connected, it is required to set up each cam-

 

 

era individually.

 

 

However, the port numbers already assigned to other hardware are

 

 

not available. The following port numbers are also not available

 

 

because this camera already uses them.

 

 

Port number: 20, 21, 23, 25, 42, 67, 68, 69, 105, 110, 123, 161,

 

 

162, 546, 547, 5002

 

 

 

Host name

Connection type 1

No setting required

 

 

 

 

Connection type 2

Refer to your network administrator and set the designated host

 

 

name if required.

 

 

 

 

Connection type 3 and 4

Refer to your Internet service provider and set the designated host

 

 

name if required.

 

 

 

BOOTP

Connection type 1 and 2

Set to ON when using the “Panasonic IP Setup” software.

 

 

 

 

Connection type 3 and 4

No setting required

 

 

 

DHCP

Connection type 1

Set to OFF.

 

 

 

 

Connection type 2

Set to ON if the intranet uses the DHCP.

 

 

 

 

Connection type 3

Set to OFF.

 

 

 

 

Connection type 4

Set to ON if the broadband router uses the DHCP.

 

 

 

DNS

Connection type 1

Set to OFF.

Connection type 2, 3 and 4 Set to ON when using the DNS.

Primary server Secondary server

Connection type 1

No setting required

Connection type 2, 3 and 4 Set the IP address of the DNS server when using the DNS.

Refer to your Internet service provider for the IP address of the DNS server. Primary and secondary IP addresses can be set for the DNS.

28

Image 28
Contents Operating Instructions English Version Important Safety Instructions Contents Advanced Settings for Operation mode Features PrefacePrecautions Do not aim the camera at bright light sourcesPlatform MPEG-4 plug-in is exclusive to Internet ExplorerTrademarks and Registered Trademarks Front View Inside of the connector coverRear View Installations Connection example ConnectionsRequired cable Using with an Intranet LAN Connection type LANUsing via the Internet Connection type Required hardwareSetup Preparations for the SetupSetup with the Provided Panasonic IP Setup Software Items included in the softwareDhcp DNS Network Setup of the PC Using Windows 98 SEScreenshot Using Windows Screenshot Using Windows XP Category View Network Connections window appears Network Setup of the Camera Basic setup page appears Click the Advanced setup button WAN Connection type Description of the parameter Bootp Installation of the MPEG-4 Plug-in Basic Settings Power/Link/Access LED Characters for Camera name Up to 32 charHour, minute and second Camera positionBrowsing Pictures Monitoring a Still Picture of a Single CameraImage capture size Quality of imageAdjustment of the brightness of the picture Panning and tiltingImage Size One time panMonitoring the Motion Picture of a Single Camera Adjustment of the brightness of the motion picture Monitoring Still Pictures of Multiple Cameras Operation mode page of Advanced setup appears How to Operate Monitoring the Picture of a Camera in a Preset Position Browsing Pictures Saving the Currently Monitored Picture on the PC Action when Motion is Detected Motion Detector FunctionInform by sending e-mails Detecting Motion in the Monitored Area External alarm input Pre-alarmPost-alarm Alarm typeSetting of the Motion Detection Area Alarm page appears Viewing the Picture Stored in the Camera To view the previous or next picture automaticallyTransferring Pictures to the Server Password ModeNon alarm transmission Check on DirectoryFile name Date & TimeTransferring Pictures to the Server when Motion is Detected Customizing the Contents of the Alarm Mail Alarm Connector and AUX Output ConnectorOther Functions Advanced Settings Advanced Settings for Operation modeOperation mode selection MPEG-4 mode setupBandwidth control Refresh intervalAdjusting the Picture Hold Sharpness PAN / Tilt calibrationSettings for the Host Authentication Access level Host addressSettings for the User Authentication Example admin System Settings Time adjustment Synchronization with NTP server Time is adjustTime setup year-month-day hourminsec NTP portDefault setting for Host name WV-NM100 User name Default setting for User nameCharacters for Password Default setting for PasswordSnmp Settings Default setting for Community name public Equipment name Default setting for Equipment nameDefault setting for Location Community nameUsing Help Firmware UpgradeTroubleshooting Possible cause / Possible solutionIf the camera and the PC are connected Same subnet If the camera and the PC are connected in a Different subnetIf Netscape Communicator is used If Internet Explorer is usedSpecifications CameraGlossary of Terms Term ExplanationTerm N1102-1013 V8QA6036BN