Bosch Appliances MIC400AL operation manual MIC-IR-12PSU

Page 24

MIC400 Series Camera Installation and Operation Manual

10.A washer drive is provided on this power supply, a mains rated relay is fitted and pre-wired to the mains input feed via an on board fuse FS4 (rated at 2 Amps Ceramic quick blow) connection to a third party washer pump system should be made via HD7 as per Table K.

11.Once connected the washer drive can be tested using the red SW1 which should activate the pump. This will allow for priming the plumbing. When pressed the LED, (LED3) next to the washer switch should illuminate. The LED will also illuminate in response to telemetry commands to switch the washer on. The Red LED on the washer PCB will illuminate when the Washer function is selected at the control room end. Note that the software in the camera prevents the washer from being run more than 10 seconds continuously. (This is to prevent the washer bottle from being inadvertently emptied. The red button on the washer drive card can be used to both test the washer operation and to prime the washer pump.

12.When wiring is complete, apply power & check the all six (6) LED’s are lit. LED1 and LED2 when light show that 15v AC is available from the power supply (i.e. the supply fuses are intact. There is no indication of the operation of the Telemetry lines as this would increase the load on these lines reducing the number of cameras that can be driven by a single telemetry spur.

LED 3 illuminates when the washer drive relay is selected to on.

LED 4 monitors the internally generated +5v rail used to drive the alarm interface circuits around HD2. This +5v supply is not available externally. LED 5 illuminates when the IR supply is selected to on by the camera telemetry.

LED 6 Pulses on/off when the MIC400 camera is correctly configured to operate with the IR power supply.

13.When satisfied the PSU is functioning correctly, re-attach the enclosure lid & screw down until tight.

EN 24

MIC-IR-12PSU

The power supply operates from a 12v DC source typically between 10.5v and 15v DC, for example, a lead acid battery. The PSU provides power to a MIC400 camera at 18v DC nominally.

Current draw:

For the camera non-moving is 600mA. Worst-case current draw whilst moving is 1.5Amps

Max current draw with camera moving, wiper on and IR illuminators on is 3.8Amps.

Dimensions

Power supply enclosure: - 260mm (W) x 90mm (H) x 120 (D)

A weather resistant (IP66) box prefitted with four cable glands.

A second isolated power supply for driving the IR illuminators, the operation of this power supply is controlled by the camera itself via telemetry commands received from the control room. The power supply operates with dual illuminators. This drive is a constant current drive which automatically configures itself for IR lamp operation. There are no adjustable items within the power supply except for the three links discussed below.

Screw termination of all third party cables into and out of the box.

Correct video termination for the camera coaxial cable.

The power supply provides a circuit for operating a 12v driven washer drive pump and reservoir system.

The power supply also supports 4 off volt free alarm contact inputs, which can be made to activate presets within the camera but always notifies the control system of the status of these alarms.

Earthing; the power supply and all equipment connected to it is earthed to the –ve side of the battery supply permanently.

Bosch Security Systems

Issue 1

Image 24
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-240PSU MIC-115PSUMIC-24PSU MIC-12PSUMIC-WKT MIC-ALMMIC-BP3 MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsUnderwater Installation Earthing of the MIC400 cameraLightning Protection NON-IR Power Supply Units Electrical ConnectionsTable a MIC Composite Cable Pin table MIC-240PSU, MIC-24PSU and MIC-115 PSUPower Supply Layout and Connections Table B Power Connection to Header HD1PCB Earth Link HD3 HD4HD5 Bi-phase cards etc Rating for PrimaryMIC-12PSU Power Supply Unit Table G Power Input wiring connections for MIC-12PSU12 or 24 Volt vehicle supply Optional Cards and Kits for Non-IR MIC400 Cameras Commissioning MIC400PA and MIC400’s with heaters fittedMIC400PA Heater OptionBosch Security Systems Issue MIC400IR Power Supply Units Setting the Power Supply Link OptionsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeSignal Table K -IR Lamp Connections HD6Terminal Box ID Marking Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Connecting the MIC400 to the PC Connecting the Greenwich AdaptorTable N Connecting the Greenwich Adaptor Adaptor ConnectionsConnecting the KK systems K2-ADE RS232 to RS485/422 Adaptor DIP SwitchSetting Table O K2-ADE Adaptor connectionsTable Q MIC-USB485CVTR Connection Table and Diagram MIC Power Supply Converter Output Telemetry HeaderCommunication Mode MIC-USB485CVTR and Universal Camset Software Installation Commissioning the MIC400 through Universal CamsetStandard Controls Boot Messages MIC SettingsCamset Settings Reset Camset Manual Control Pan, Tilt and Zoom ControlsIris Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesMIC Setups General SettingsPan Reverse Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Frame Integration Settings Privacy and CaptionsLens Recalibration and Frame Integration Privacy Controls Privacy Calibration CaptionsThermal Advanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier Download Eeprom To FileUpload Eeprom From File Remap Auxiliary Pelco OnlyPOT Test Menu Controls Panasonic OnlyMatrix Controls Pot Test Controls Pot Test ResultsSend Direct Command CommsCommunications Testing AlarmsMIC Comms Cam CommsSonySet Preset Number Get Preset from MICSend Preset to MIC Sony SetExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Alarms Camera ModuleOperational Communication & ProtocolsAccessories PhysicalEnvironmental ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncAppendix a Protocol Preset codes Preset CodesPelco Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2