Bosch Appliances MIC400AL operation manual Privacy Calibration, Captions

Page 42

MIC400 Series Camera Installation and Operation Manual

Privacy Calibration

CAUTION: The Privacy Calibration settings should be configured at manufacture and should therefore not need to be changed on site.

Any changes to these settings may be difficult to correct, so please do not attempt to change anything unless under instruction from Bosch.

The Privacy Calibration section deals with the calibration settings of the privacy masking. I.e. how the masks track as the MIC is moved in Pan, Tilt or Zoom.

MIC Configuration

These options define the MIC's orientation, which defines how the masks track. for Inverted MICs, the head would normally be rolled around through 180 degrees, with Pan Reverse On to regain sensible control. However, with inverted IR MICs, the head cannot be rotated around due to the IR Lamp arms and therefore the video must be inverted and both controls reversed.

Basic Calibration

This sends a set of default commands to the MIC to initialise the privacy for an upright MIC. This will not be perfect as each board needs fine individual calibration but provides a good starting point.

Zoom Alignment

The zoom alignment buttons provide accurate calibration of the mask tracking. This would normally be carried out by using a vertical line of mask on along a known straight edge. If this line then moves as the MIC pans and tilts, it can be corrected using the appropriate arrow. The labels indicate the current value in both the Vertical and Horizontal planes, which will be incremented or decremented dependant upon the direction pressed.

Direct Command

All privacy commands consist of 2 Hex bytes, a command byte and a data byte. These perform all of the privacy functions available. To enter a command, enter the 2 bytes, in Hex, into the boxes provided and press Send Command. Entering random commands here may result in very odd results so please do not use unless under specific instruction.

EN 42

Save Current Settings

Once any calibration changes are made, this button should be pressed to save the new values permanently.

Captions

The Captions tab allows the user to set up captions, Sector or Preset Captions; Screen Location and Caption Colour are all user definable.

The MIC has 3 different caption options available. On the MIC 400 model range only one line of text is available and therefore a Preset Caption will overwrite a Default Caption.

The Default Caption can be treated as the name of the camera. It will appear on the video whenever it can, i.e. when no Preset or Sector captions are selected.

Preset Captions can be used to display a different title for each of the preset positions available. This will be loaded once the MIC has reached the position. As an alternative, the same 64 captions can be used, not for preset positions but for rotational sectors. The MIC’s pan is split into 64 segments and a different caption can be assigned to each or to a group. Using this option can result in an occasional slight control lag.

Bosch Security Systems

Issue 1

Image 42
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-24PSU MIC-240PSUMIC-115PSU MIC-12PSUMIC-BP3 MIC-WKTMIC-ALM MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsUnderwater Installation Earthing of the MIC400 cameraLightning Protection Table a MIC Composite Cable Pin table NON-IR Power Supply UnitsElectrical Connections MIC-240PSU, MIC-24PSU and MIC-115 PSUPower Supply Layout and Connections Table B Power Connection to Header HD1PCB Earth Link HD3 HD4HD5 Bi-phase cards etc Rating for PrimaryMIC-12PSU Power Supply Unit Table G Power Input wiring connections for MIC-12PSU12 or 24 Volt vehicle supply MIC400PA Optional Cards and Kits for Non-IR MIC400 CamerasCommissioning MIC400PA and MIC400’s with heaters fitted Heater OptionBosch Security Systems Issue MIC400IR Power Supply Units Setting the Power Supply Link OptionsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeTerminal Box ID Marking SignalTable K -IR Lamp Connections HD6 Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Table N Connecting the Greenwich Adaptor Connecting the MIC400 to the PCConnecting the Greenwich Adaptor Adaptor ConnectionsSetting Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorDIP Switch Table O K2-ADE Adaptor connectionsTable Q MIC-USB485CVTR Connection Table and Diagram MIC Power Supply Converter Output Telemetry HeaderCommunication Mode MIC-USB485CVTR and Universal Camset Software Installation Commissioning the MIC400 through Universal CamsetStandard Controls Boot Messages MIC SettingsCamset Settings Iris Controls Reset CamsetManual Control Pan, Tilt and Zoom Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesPan Reverse MIC SetupsGeneral Settings Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Frame Integration Settings Privacy and CaptionsLens Recalibration and Frame Integration Privacy Controls Privacy Calibration CaptionsThermal Timers Advanced SettingsTemperature and Humidity Clear All StatisticsUpload Eeprom From File Eeprom CopierDownload Eeprom To File Remap Auxiliary Pelco OnlyPOT Test Menu Controls Panasonic OnlyMatrix Controls Pot Test Controls Pot Test ResultsSend Direct Command CommsMIC Comms Communications TestingAlarms Cam CommsSend Preset to MIC SonySet Preset NumberGet Preset from MIC Sony SetSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Operational AlarmsCamera Module Communication & ProtocolsEnvironmental AccessoriesPhysical ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncAppendix a Protocol Preset codes Preset CodesPelco Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2