Bosch Appliances MIC400AL operation manual Auxiliaries, Preset Positions

Page 34

MIC400 Series Camera Installation and Operation Manual

Auxiliaries

Slow Zoom: Reduces the speed at which the MIC zooms.

PTZ Scale: Scales the MIC speed dependant on zoom position.

Wiper: Turns on or off the MIC wiper if fitted.

Washer: Activates the washer relay on the MIC-WKT card or the MIC-ALM card if fitted in the PSU. This also moves the MIC to the stored WashWipe position and turns on the wiper. Once de-activated the MIC will return to its original position and turn off the wiper.

IR / Thermal: Dependant on the MIC this will do one of 3 things, for a Non-IR Standard MIC the IR cut filter will come in and the image will go black and white. For a twin IR MIC, the cut filter will come in and the lamps will turn on.

Note: If the lamps do not turn on, ensure the power supply is an IR version and that Auto Alarm and Multi Alarms in the MIC Setup tab are both turned on.

For a MIC412, the video output will switch from the Sony module to the thermal module; the controls on the Thermal tab will also now function.

Digital Zoom: This will enable the MIC to continue into the digital zoom once the optical limit has been reached. This also needs to have Digital Zoom Enabled under the MIC Setup tab.

Auto Pan: This will start the MIC panning between left and right defined limits.

On Screen Data: This activates the Sony modules on screen icons.

EN 34

Preset Positions

Preset positions are locations stored by the MIC in Pan, Tilt and Zoom, Focus etc, which can be either called back manually, or returned to as part of a preset position tour.

To learn a position move the MIC to the desired location and then either enter in the preset number in the box available or press the Preset Number button until it displays the desired value. Then press the Learn button to store. Once stored the value in the input box will be cleared.

Returning to a position uses the same number entry method and then press the Go To instead.

The Learn All Presets button will set every preset position available for the given protocol to the current position. This may take a few seconds.

Bosch Security Systems

Issue 1

Image 34
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-24PSU MIC-240PSUMIC-115PSU MIC-12PSUMIC-BP3 MIC-WKTMIC-ALM MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsEarthing of the MIC400 camera Underwater InstallationLightning Protection Table a MIC Composite Cable Pin table NON-IR Power Supply UnitsElectrical Connections MIC-240PSU, MIC-24PSU and MIC-115 PSUTable B Power Connection to Header HD1 Power Supply Layout and ConnectionsPCB Earth Link HD4 HD3HD5 Bi-phase cards etc Rating for PrimaryTable G Power Input wiring connections for MIC-12PSU MIC-12PSU Power Supply Unit12 or 24 Volt vehicle supply MIC400PA Optional Cards and Kits for Non-IR MIC400 CamerasCommissioning MIC400PA and MIC400’s with heaters fitted Heater OptionBosch Security Systems Issue Setting the Power Supply Link Options MIC400IR Power Supply UnitsMIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeTerminal Box ID Marking SignalTable K -IR Lamp Connections HD6 Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Table N Connecting the Greenwich Adaptor Connecting the MIC400 to the PCConnecting the Greenwich Adaptor Adaptor ConnectionsSetting Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorDIP Switch Table O K2-ADE Adaptor connectionsMIC Power Supply Converter Output Telemetry Header Table Q MIC-USB485CVTR Connection Table and DiagramCommunication Mode Commissioning the MIC400 through Universal Camset MIC-USB485CVTR and Universal Camset Software InstallationStandard Controls Boot Messages MIC SettingsCamset Settings Iris Controls Reset CamsetManual Control Pan, Tilt and Zoom Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesPan Reverse MIC SetupsGeneral Settings Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Privacy and Captions Frame Integration SettingsLens Recalibration and Frame Integration Privacy Controls Privacy Calibration CaptionsThermal Timers Advanced SettingsTemperature and Humidity Clear All StatisticsUpload Eeprom From File Eeprom CopierDownload Eeprom To File Remap Auxiliary Pelco OnlyMenu Controls Panasonic Only POT TestMatrix Controls Pot Test Controls Pot Test ResultsSend Direct Command CommsMIC Comms Communications TestingAlarms Cam CommsSend Preset to MIC SonySet Preset NumberGet Preset from MIC Sony SetSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Operational AlarmsCamera Module Communication & ProtocolsEnvironmental AccessoriesPhysical ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncPreset Codes Appendix a Protocol Preset codesPelco Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2