Bosch Appliances MIC400AL operation manual Other controls, Default Settings

Page 38

MIC400 Series Camera Installation and Operation Manual

Other controls

Learn Wash Position

This is the position that the MIC will return to when the Washer Auxiliary is activated and Wash Wipe is turned on. This should point towards the washer jet nozzle.

Learn Alarm Position

This is the alarm position for the tamper switch. The MIC will return to this position if Auto Alarm is turned on, Multi Alarm is turned off and the tamper line in the PSU is pulled to ground.

Find End Stops

This will get the MIC to rotate in the tilt axis first down then up to its mechanical limit stops. It will then store a "soft" limit a few units back from these for normal use. During this process manual control is not available.

Show Boot Message

This will display the boot message that appears on the video for a few seconds, this may be helpful to determine the current software of the MIC, without having to do a full reboot.

Self Diagnosis

This function is for future products and does not work with the MIC400 or MIC412.

EN 38

Default Settings

The Default Settings tab reads and sets settings from the following sections:

-Manual Control Auxiliaries

-General Settings

-Auto Home Controls

-Multi Alarm Settings

-Lens Recalibration

-Frame Integration Settings

-All Thermal controls

All other settings will not be saved, loaded, downloaded or set through the following controls.

Get Current MIC Settings

This downloads the current status of each of the settings from the MIC and loads it into the text boxes and radio buttons on Camset. This provides an easy way of viewing the current setup of each MIC and also a way of copying the settings from one into the next.

Bosch Security Systems

Issue 1

Image 38
Contents MIC400 PTZ Camera Series MIC400 PTZ Camera Series Introduction Safety Precautions Important Safety Instructions Reference MIC-24PSU MIC-240PSUMIC-115PSU MIC-12PSUMIC-BP3 MIC-WKTMIC-ALM MIC-BP4Packaging Contents UnpackingInstallation Environment Key to MIC-PMB drawing Associated Equipment & Typical Installations Installation InstructionsLightning Protection Underwater InstallationEarthing of the MIC400 camera Table a MIC Composite Cable Pin table NON-IR Power Supply UnitsElectrical Connections MIC-240PSU, MIC-24PSU and MIC-115 PSUPCB Earth Link Power Supply Layout and ConnectionsTable B Power Connection to Header HD1 HD5 HD3HD4 Bi-phase cards etc Rating for Primary12 or 24 Volt vehicle supply MIC-12PSU Power Supply UnitTable G Power Input wiring connections for MIC-12PSU MIC400PA Optional Cards and Kits for Non-IR MIC400 CamerasCommissioning MIC400PA and MIC400’s with heaters fitted Heater OptionBosch Security Systems Issue MIC-IR-240PSU, MIC-IR-115PSU, MIC-IR-24PSU and MIC-IR-12PSU MIC400IR Power Supply UnitsSetting the Power Supply Link Options Figure D MIC-IR-240PSU Layout Table I Fuse Ratings for MIC-IR-240PSU Function TypeTerminal Box ID Marking SignalTable K -IR Lamp Connections HD6 Table L -Washer Pump Connection HD7MIC-IR-12PSU Figure E MIC-IR-12PSU Schematic Table M Fuse ratings for MIC-IR-12PSU Function Type RatingInstallation Instructions Table N Connecting the Greenwich Adaptor Connecting the MIC400 to the PCConnecting the Greenwich Adaptor Adaptor ConnectionsSetting Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorDIP Switch Table O K2-ADE Adaptor connectionsCommunication Mode Table Q MIC-USB485CVTR Connection Table and DiagramMIC Power Supply Converter Output Telemetry Header Standard Controls MIC-USB485CVTR and Universal Camset Software InstallationCommissioning the MIC400 through Universal Camset Boot Messages MIC SettingsCamset Settings Iris Controls Reset CamsetManual Control Pan, Tilt and Zoom Controls Focus ControlsPreset Positions AuxiliariesTour Controls Soft Stops and Non Dwell ZonesPan Reverse MIC SetupsGeneral Settings Tilt ReverseAuto Home Controls Default Settings Other controlsMulti Alarm Settings Lens Recalibration and Frame Integration Frame Integration SettingsPrivacy and Captions Privacy Controls Privacy Calibration CaptionsThermal Timers Advanced SettingsTemperature and Humidity Clear All StatisticsUpload Eeprom From File Eeprom CopierDownload Eeprom To File Remap Auxiliary Pelco OnlyMatrix Controls POT TestMenu Controls Panasonic Only Pot Test Controls Pot Test ResultsSend Direct Command CommsMIC Comms Communications TestingAlarms Cam CommsSend Preset to MIC SonySet Preset NumberGet Preset from MIC Sony SetSave Table from MIC to File Execute this PresetLoad Table from File to MIC Clear TableTable R Sonyset Commands MIC Programmer Bosch Security Systems Issue Operational AlarmsCamera Module Communication & ProtocolsEnvironmental AccessoriesPhysical ElectricalMIC400PA Twin SpeakersMIC400UL and MIC400UT MIC400S MIC400IR IR IlluminatorsDimension Drawings Asia-Pacific Contact AmericasEurope, Middle East, Africa Bosch Security Systems IncPelco Appendix a Protocol Preset codesPreset Codes Bosch Security Systems Special Setup Presets VisionBosch Security Systems Issue American Dynamics Kalatel Impossible to reach Molynx Panasonic Privacypresetend Multialarmpreset Bosch Forward Vision VCL Pantiltscaleonpreset Vicon PRIVACYSETUPBYTE2